• Title/Summary/Keyword: Verification test

Search Result 2,695, Processing Time 0.039 seconds

An Empirical Validation Study for Calibration Verification in TDM Test (검량보정 검증의 실험적 적합성에 대한 연구 -치료적 약물검사를 중심으로-)

  • Chang, Sang-Wu;Kim, Nam-Yong;Choi, Ho-Sung;Park, Yong-Won;Chu, Gyung-Bok;Yun, Keun-Young;Park, Byung-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The purpose of this study was to verify (i) a consistent calibration verification for the assessment of method linearity and (ii) calibration agreement with calibration settings. We validated calibration verification through method linearity with different lot number of individual calibrators that span the working range for 9 tests except salicylate with control sample in test. We evaluated that it covered broad analyte range to assay from near zero to the top of the measuring range with 5 or 6 points every three times for 10 analytes in TDM test. Target values were plotted on X-axis with assigned or observed values on the Y-axis. Working range were as follows. Calibration verification of the measuring range (maximum to minimum values) has been validated asetaminophen 0.1 to $304.6_{\mu}g/mL$, salicylate 0 to $1005_{\mu}g/mL$, valproic acid 3.2 to $154.19_{\mu}g/mL$, digoxin 0.17 to 5.65 ng/mL, vancomycine 1.3 to $80.51_{\mu}g/mL$, carbarmazepine 0.1 to $22.3_{\mu}g/mL$, phenytonin 0.6 to $40.21_{\mu}g/mL$, theophyline 0.2 to $40.21_{\mu}g/mL$, primidone 0 to $24.07_{\mu}g/mL$, phenobarbital 0.6 to $60.0_{\mu}g/mL$. Drawing a straight line through five or six points of these data showed good linearity. We are sure that it is important to assess the calibration verification of a test method to ascertain the lowest and highest test results that are reliable.

  • PDF

Design and Implementation of BioAPI v2.0 based BSP Conformance Test Suite (BioAPI v2.0 기반 BSP 표준 적합성 시험 도구의 설계 및 구현)

  • Jang Ji-Hyeon;Lee Dong-Geun;Kim Jae-Sung;Kim Hak-Il
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.16 no.3
    • /
    • pp.129-141
    • /
    • 2006
  • The purpose of this paper is to design Conformance Test Suite for BSP(Biometric Service Provider) based on BioAPI(Biometric Application Programming Interface) v2.0. The proposed BioAPI Conformance Test Suite enables users to test BSP with framework independently. A test scheduling tool has been embodied to use Test Assertion in the form of XML. In order to demonstrate the performance of the Conformance Test Suite, the experiment was performed by using both verification and identification BSPs. As the results of this experiment, we were able to determinate whether BSPs based on BioAPI v2.0 satisfied standard requirements or not.

Design of Cold-flow Test Equipment Considering Dynamic Similarity for DACS Verification (동적상사를 고려한 DACS 검증용 공압 시험장치 설계)

  • Bae, Sangho;Chang, Hongbeen;Park, Iksoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.374-377
    • /
    • 2017
  • A cold-flow test equipment was designed to carry out the performance verification of TDACS. For that purpose, the pressure dynamics in the solid rocket motor combustor and the cold-flow test was modeled, and the response time showing the dynamic characteristics of each model was obtained. In this paper, the system response time of the cold-flow test was designed to be equal to that of the motor, making the dynamic response in cold-flow and hot gas condition to be similar.

  • PDF

Modeling and verification of generator/control system of Seo-Inchon combined-cycle plant by load rejection test (부하차단시험에 의한 서인천복합화력 발전기.제어계의 모델링 및 검증)

  • 최경선;문영환;김동준;추진부;류승헌;권태원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.501-510
    • /
    • 1996
  • The gas-turbine generator of Seo-Incheon combined-cycle plant was tested for derivation of a model for dynamic analysis. Load rejection and AVR step test was performed to get the dynamic response of generator. The parameters of generator/control system model were determined by these measured data. No-load saturation test was performed for the saturation characteristics of the generator under steady state. V-curve test was also performed so as to find exact generator parameters. Q-axis parameters of generator was derived by measuring power angle. AVR and governor constants have been tuned by their oscillatory period and setting time characteristics. The derived parameters of generator control system is verified by one-machine infinite bus system simulation. (author). 7 refs., 20 figs., 5 tabs.

  • PDF

Numerical estimation of errors in drop angle during drop tests of IP-Type metallic transport containers for radioactive materials

  • Lim, Jongmin;Yang, Yun Young;Lee, Ju-chan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1878-1886
    • /
    • 2021
  • For industrial package (IP)-type transport containers for radioactive materials, a free drop test should be conducted under regulatory conditions. Owing to various uncertainties observed during the drop test, errors in drop angles inevitably occur. In IP-type metal transport containers in which the container directly impacts onto a rigid target without any shock absorbing materials, the error in the drop angle due to a slight misalignment makes a significant difference from the ideal drop. In particular, in a vertical drop, the error in the drop angle causes a strong secondary impact. In this paper, a numerical method is proposed to estimate the error in the drop angle occurring during the test. To determine this error, an optimization method accompanying a computational drop analysis is proposed, and a surrogate model is introduced to ensure calculation efficiency. Effectiveness of the proposed method is validated by performing the verification and comparison between the test and the analysis applied with the drop angle error.

Monte Carlo simulation for verification of nonparametric tests used in final status surveys of MARSSIM at decommissioning of nuclear facilities

  • Sohn, Wook;Hong, Eun-hee
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1664-1675
    • /
    • 2021
  • In order to verify the statistical performance of the nonparametric tests used in the MARSSIM approach, all plausible contamination distribution types that can be encountered in a survey area should be investigated. As the first of such investigations, this study aims to perform the verification for normal distribution of the contamination in a survey area by simulating the collection of random samples from it through the Monte Carlo simulation. The results of the simulations conducted for a total of 81 simulation cases showed that Sign test and WRS test both exhibited an excellent statistical performance: 100% for the former and 98.8% for the latter. Therefore, in final status surveys of the MARSSIM approach, a high statistical performance can be expected in applying the nonparametric hypothesis tests to survey areas whose net contamination can be assumed to be normally distributed.

Development of ESAD with Flight Environment Sensing Function and Sled Test Method for Function Verification (비행환경 감지 기능을 보유한 ESAD 개발 및 기능 확인을 위한 슬레드 시험 방안)

  • Hanseong Jo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.273-280
    • /
    • 2023
  • Recently electronic safety and arming device(ESAD) has attracted increasing attention due to its design flexibility. However, ESAD can be armed unintentionally due to a malfunction of an external device or interface. Thus ESAD needs an internally generated arming signal independent from the external device. In this paper, a new sensor-hybrid ESAD(SHESAD) with a flight environment sensing function for generating arming signal internally is proposed and a sled test based method is also suggested for evaluating its functions. Through the test results, the operability of the flight environment sensing function was confirmed. Also, it is shown that the proposed test method is suitable for verification of ESAD with the flight environment sensing function.

A Study of the flight s/w test environment for the LEO satellite (저궤도위성 탑재소프트웨어 시험환경에 대한 연구)

  • Chae, Dong-Seok;Lee, Jae-Seung;Choi, Jong-Wook;Yang, Seung-Eun;Lee, Jong-In
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.45-51
    • /
    • 2007
  • The various levels of test are performed to verify the correctness, completeness, and quality of the developed flight software. The three main test levels are unit test, integration test and verification test. The flight software unit test is performed on the individual PC environment using target simulator. And integration and verification test is mainly performed on STB(S/W Test Bed) which provides test and debugging environments for flight software on the target board This document is to present the test environment for the next generation low earth orbit satellite flight software development.

  • PDF

A Verification Test on Safety Standards of Portable Propane Gas Stove for Safe Camping Culture (안전한 캠핑 문화의 정착을 위한 야외용 프로판 연소기 안전기준 실증 연구)

  • Ahn, Hyun-Soo;Choi, Suel-Ki;Lee, Chang-Eon;Kim, Young-Gu
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.293-294
    • /
    • 2014
  • In Korea, only butane gas could be used as fuel gas of the outdoor gas stove. However, butane is not vaporized well at low temperatures. For this reason, in the field, nozzle of the portable butane gas stove is converted illegally to use propane gas. Because vapor pressure of propane gas is higher than that of butane gas at same temperature, gas accidents such as gas leakage could be occurred. To prevent gas accidents and use portable propane gas stoves safely, international standards need to be analyzed and verification tests need to be performed with prototype stove. This study could suggest to revise standard for safety improvement with portable propane gas stoves.

  • PDF

Experimental Performance Verification of Load Carrying Capacity Algorithm of Bridges using Ambient Vibration (상시진동을 이용한 교량 내하력 추정 알고리즘의 실험적 성능 검증)

  • Lee, Woo-Sang;Park, Ki-Tae;Han, Sung-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.83-90
    • /
    • 2010
  • In this study, it is conducted that the performance verification of the ambient load carrying capacity algorithm using long-term measurement systems of bridges. For this purpose, a steel-box type model bridge is fabricated and the public load carrying capacity of a steel-box model bridge is estimated by conducting the numerical analysis and load test. In addition, we compare the public load carrying capacity with the estimated result of a steel-box model bridge using the ambient load carrying capacity algorithm. By the assessment result, it is shown that the estimated ambient load carrying capacity is the difference of approximately 6.0 percentages as compared with the public load carrying capacity.