• Title/Summary/Keyword: Verification method and regulations

Search Result 43, Processing Time 0.032 seconds

Performance Verification and Reliability Test of Load Cell Gauge in Korea (국내 하중계 성능검증과 신뢰성 시험 연구)

  • Kim, Yeong-Bae;Park, Yeong-Bae;Lee, Seong-Won;Lee, Kang-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.12
    • /
    • pp.103-114
    • /
    • 2023
  • Monitoring the site of an underground construction wall is crucial to confirm the stability of the supports and ground due to excavation. In particular, it is essential to maintain the accuracy of a load cell gauge, which identifies the load of the support transmitted from the excavated ground. However, research on verification methods and regulations that can identify the accuracy of load cell gauges at construction sites is inadequate, which is a problem as load cell gauges are installed without proper performance inspections. In this study, performance tests were conducted by a complete investigation of load cell gauges sold in Korea and comparing them with foreign products to determine defect causes. In addition, the criteria for selecting a load cell gauge were presented, and the results of this study were considered to help select a highly reliable load cell gauge.

Synchronization and identification of ship shaft power and speed for energy efficiency design index verification

  • Lee, Donchool;Barro, Ronald Dela Cruz;Nam, Jeonggil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.123-132
    • /
    • 2014
  • The maritime sector is advancing with dedicated endeavor to reduce greenhouse gas in addressing issues with regards to global warming. Since 01 January 2013, the International Maritime Organization (IMO) regulation mandatory requirement for Energy Efficiency Design Index (EEDI) has been in place and should be satisfied by newly-built ships of more than 400 gross tonnage and the Ship Energy Efficiency Management Plan (SEEMP) for all ships type. Therefore, compliance to this necessitates planning during the design stage whereas verification can be carried-out through an acceptable method during sea trial. The MEPC-approved 2013 guidance, ISO 15016 and ISO 19019 on EEDI serves the purpose for calculation and verification of attained EEDI value. Individual ships EEDI value should be lower than the required value set by these regulations. The key factors for EEDI verification are power and speed assessment and their synchronization. The shaft power can be measured by telemeter system using strain gage during sea trial. However, calibration of shaft power onboard condition is complicated. Hence, it relies only on proficient technology that operates within the permitted ISO allowance. On the other hand, the ship speed can be measured and calibrated by differential ground positioning system (DGPS). An actual test on a newly-built vessel was carried out to assess the correlation of power and speed. The Energy-efficiency Design Index or Operational Indicator Monitoring System (EDiMS) software developed by the Dynamics Laboratory-Mokpo Maritime University (DL-MMU) and Green Marine Equipment RIS Center (GMERC) of Mokpo Maritime University was utilized for this investigation. In addition, the software can continuously monitor air emission and is a useful tool for inventory and ship energy management plan. This paper introduces the synchronization and identification method between shaft power and ship speed for EEDI verification in accordance with the ISO guidance.

The Case Studies of Artificial Intelligence Technology for apply at The Sewage Treatment Plant (국내 하수처리시설에 인공지능기술 적용을 위한 사례 연구)

  • Kim, Taewoo;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.4
    • /
    • pp.370-378
    • /
    • 2019
  • In the recent years, various studies have presented stable and economic methods for increased regulations and compliance in sewage treatment plants. In some sewage treatment plants, the effluent concentration exceeded the regulations, or the effluent concentration was manipulated. This indicates that the process is currently inefficient to operate and control sewage treatment plants. The operation and control method of sewage treatment plant is mathematically dealing with a physical and chemical mechanism for the anticipated situation during operation. In addition, there are some limitations, such as situations that are different from the actual sewage treatment plant. Therefore, it is necessary to find a more stable and economical way to enhance the operational and control method. AI (Artificial Intelligence) technology is selected among various methods. There are very few cases of applying and utilizing AI technology in domestic sewage treatment plants. In addition, it failed to define specific definitions of applying AI technologies. The purpose of this study is to present the application of AI technology to domestic sewage treatment plants by comparing and analyzing various cases. This study presented the AI technology algorithm system, verification method, data collection, energy and operating costs as methods of applying AI technology.

A Study on Method for Bypassing Verification Function by Manipulating Return Value of Android Payment Application's Security Solution (안드로이드 간편결제 애플리케이션 보안 솔루션 결과값 변조를 통한 검증기능 우회 방법에 대한 연구)

  • You, Jaewook;Han, Mijeong;Kim, Kyuheon;Jang, Junyoung;Jin, Hoyong;Ji, Hanbyeol;Shin, Jeonghoon;Kim, Kyounggon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.4
    • /
    • pp.827-838
    • /
    • 2018
  • Since 2014, ease of regulations on financial institutions expanded the mobile payment market based on simple authentication, and this resulted in the emergence of various simple payment services. Although several security solutions have been used to mitigate possible security threats to payment applications, there are vulnerabilities which can still be found due to the structure in which the security solution is applied to the payment service. In this paper, we analyze the payment application and security solution from the process perspective, and prove through experimentation that verification functions of security solutions can be bypassed without detailed analysis of each security function, but by simply manipulating the verification result value. Finally, we propose methods to mitigate the bypass method presented in this paper from three different perspectives, and thereby contribute to the improvement of security level of the payment service.

A Study on the Quantitative and Evaluation Weights of National Greenhouse Gas Emission Factors in the Mineral Industry (광물산업의 국가온실가스배출계수 정량·평가항목 가중치에 관한 연구)

  • Yoon, Yoongjoong;Cho, Changsang;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.9 no.1
    • /
    • pp.81-90
    • /
    • 2018
  • "The Framework Act on Low-Carbon Green Growth" specifies the requirements for the development and verification of emission factors for establishing reliable national greenhouse gas statistics. The scope of the regulations covers the development and validation of energy, industrial processes, solvents and other product use, agriculture, land use, land use change and emission and absorption coefficients of the forestry and waste sector as defined in the 1996 IPCC Guideline and GPG 2000, The minerals sector to be covered in this study belongs to industrial processes. As a representative method for quantifying and evaluating GHG emission factors, there are emission grade quality grading and DARS (Data Rating Rating System) in the 'Procedures for Preparing Emission Factor Documents (1997)' reported by US-EPA. However, the above two methods are not specific and comprehensive, and lack the details for accurate emission factor verification. Therefore, there is a need for a method for verifying and quantifying certified greenhouse gas emission factors that reflects characteristics of each industry sector in Korea and accord with IPCC G/L and GHG target management. In this study, we conducted a weighted study on quantitative and evaluation lists of emission factor using questionnaires to develop a more accurate methodology for quantifying national greenhouse gas emission factors in the mineral sector. Quantification and evaluation of emission factor are classified into essential verification and quality evaluation. The essential verifications are : administrative compatibility, method of determining emission factors, emission characteristics, sampling methods and analysis methods, representativeness of data. The quality evaluations consisted of the quality control of the data, the accuracy of the measurement and analysis, the level of uncertainty, not directly affect the emission factor, but consisted of factors that determine data quality.

The Application Technology of Korean-style R&D in Verification for deploying the Neo-Korean Style Public Building - Focused on the R&D Technologies in Changed Drawings of Neo-Korean Style Public Daycare Center in Sunchang-gun, Korea -

  • Kim, Young-Hoon;Peck, Yoo-Jung;Park, Joon-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.35-46
    • /
    • 2015
  • Purpose: This study is to research how New-Hanok R&D technologies of first stage are appearing and adapted to the New-Hanok style public buildings, especially in Daycare Center in Sunchang-gun, Korea. Unlike Hanok houses, public buildings which has special needs for the public and restricted by laws and regulations need not only new system of law incentives but also new components of New-Hnaok R&D technologies used only in Hanok house. Method: For this purpose, we checked the drawings for Daycare Center in Sunchang-gun. The drawings have been changed 6 times for the purpose of adopting New-Hanok R&D technologies of first stage and actual needs for current laws and regulations for public buildings and it reveals not only the possibilities for adapting new technologies in New-Hanok but also meetings the current and public needs for public buildings. Result: The result of this study as follows. Approximately 40-50 percent of New-Hanok R&D technologies in the first stage are adapted in Daycare Center in Sunchang-gun, and this means there are limitations in adapting New-Hanok R&D which are mainly for the Korean style houses. The main reasons are the costs still remaining high and lacking in confidence for using traditional structures and materials still under verification. Some are changed and proposed in another solutions suitable for public buildings as like truss structure system in roof.

Implementation of One-Cycle Control for Switched Capacitor Converters

  • Yang, Lei;Zhang, Xiaobin;Li, Guann-pyng
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2057-2066
    • /
    • 2016
  • An extension of the one-cycle control (OCC) method for switched-capacitor (SC) converters is proposed in this paper, featuring a fast dynamic response, wide line and load operation ranges, and simplicity in implementation. To illustrate the operation principle of this nonlinear control method and to demonstrate its simplicity in design, a dual-phase unity gain SC converter is examined. A new control loop based on the charge balance in a flying capacitor is formulated for the OCC technique and implemented with a 15W dual-phase unity gain SC converter on a circuit board for control verification. The obtained experimental results show that external disturbances can be rejected in one switching cycle by the OCC controlled SC converter with good line and load regulations. When compared to other control methods, the proposed nonlinear control loop exhibits superior dynamic performance in suppressing input and load disturbances.

A study on the Seismic Performance Evaluation Process for Urban Railway Bridges (도시철도 교량의 내진성능 평가체계에 관한 연구)

  • Park, Beom-Ho;Lee, Tae-Hyung;Kim, Kee-Dong;Lim, Nam-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1143-1147
    • /
    • 2010
  • The verification of the seismic performance of many urban railway bridges will be done or is done by the regulations of "Seismic Performance Evaluation Methods(Tips) of Existing Bridges" developed by KISTEC in 2004. This present process may involve some of the issues such as the unreflecting of the characteristics of the urban railway bridge and the appearance of ductility-based seismic design method. In this paper, the new and improved seismic performance evaluation system is proposed.

  • PDF

Numerical simulation of a regenerative thermal oxidizer for volatile organic compounds treatment

  • Hao, Xiaowen;Li, Ruixin;Wang, Jiao;Yang, Xinfei
    • Environmental Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.397-405
    • /
    • 2018
  • As regulations governing the control of volatile organic compounds (VOCs) have become increasingly stringent in China, regenerative thermal oxidizers (RTOs) have been more frequently applied in medium- and high-concentration VOCs treatments. However, due to the lack of existing RTO-related research, experience remains a dominant factor for industrial application. This paper thus aimed to establish a model for industrial RTOs, using a transient simulation method and thermal equilibrium model to simulate the internal velocities and temperature distributions of an RTO across multiple cycles. A comparison showed an error of less than 5% between most correlating simulated and experimental measurement points, verifying that the simulation method was accurate. After verification, the velocity and temperature fields inside the RTO were simulated to study the uniformity of temperature and velocity within the packed beds: both fields displayed high uniformity after gas flowed through the honeycomb regenerator. The effects of air volume, VOCs concentrations, and valve switching times on the oxidation chamber temperature, RTO outlet temperature, and thermal efficiency (as well as their averages) were studied. The VOCs removal rate in this study was constantly above 98%, and the average thermal efficiency reached 90%.

Development of Key Performance Indicators in Ammunition Demilitarization Facility Using the Balanced Score Card (균형성과표(BSC)를 활용한 탄약 비군사화 시설의 핵심성과지표 개발)

  • Bae, Young-Min;Han, Seung-Jo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.1
    • /
    • pp.17-25
    • /
    • 2021
  • Ammunition Demilitarization facility (ADF) should be set up the feasible goals and continue to operate, taking into account non-profit characteristics. However, due to the lack of performance measurement methods in ADF, which are essential to national policy at a significant cost each year, the reliability of the evaluation results can be insufficient. In this paper, the Balanced Score Card (BSC) method was applied that could be evaluated to reflect the financial and non-financial features. The relevant literature research and army regulations reflected the results of various interviews of the expert group. The extraction of success performance area in ADF was confirmed using the BSC method and the Decision Variable (DV) candidate was created to use regression for selecting the DV. Additionally, the key performance indicator was presented by verification the feasibility of content by conducting the survey of experts. The implications of this paper are as follows. First, the proposed BSC model was found to be suitable for practical use in ADF reflecting the non-profit characteristics. Second, accurate evaluation of ADF can contribute to long-term development of ADF. Finally, it can be applied to the management process of the other military sector, so it can be expected to play a role in providing basic data and spreading it to other areas.