• Title/Summary/Keyword: Ventilation rate

Search Result 821, Processing Time 0.032 seconds

Effect of Ambient Air Temperature on the Pattern of Clothing Ventilation through Openings (환경 온도가 개구부를 통한 의복의 환기 양상에 미치는 영향)

  • 추미선
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.6
    • /
    • pp.793-801
    • /
    • 2002
  • The effects of ambient air temperature on the clothing ventilation were investigated numerically by a finite difference method. Numerical analysis using a 2-dimensional model comprising the air space between the skin and the clothing was conducted under the assumption that the clothing ventilation occurred only through the openings not through the fabric. The larger the temperature difference between the skin and the surroundings, the more apparent the thermal boundary layer As the ambient air temperature decreased, the air flow and the rate of the return of oxygen concentration to the atmosphere level in the clothing increased. Convection was dominant under low ambient air temperature, whereas conduction was dominant under high ambient air temperature. The ventilation rate was faster in the clothing microenvironment of the body part than that of the arm part.

  • PDF

An Experimental Study of Ventilation Effectiveness in Mechanical Ventilation systems using a Tracer Gas Method

  • Lee, Jae keun;Kang, Tae-Wook;Lee, Kam-Gyu;Cho, Min-Chul;Shin, Jin-Hyuk;Kim, Seong-Chan;Koo, Jeong-Hwan;Lee, Jong ho
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.11
    • /
    • pp.1286-1295
    • /
    • 2000
  • The ventilation effectiveness is evaluated as a function of air exchange rate and supply / extract locations in a simplified model chamber using a tracer gas technique of CO$_2$ gas injected into a supply duct. Ventilation systems consist of supply and extract fans, a CO$_2$gas generator, a CO$_2$gas analyzer and a test chamber. The ventilation effectiveness is evaluated using a step-down method based on ASTM Standard E741-83. The room mean age of the model chamber is decreased with increasing air exchange rate fanged from 6to 10 air changes per hour. The ventilation effectiveness of the mechanical inlet/natural extract system is better than that of the mechanical extract system.

  • PDF

A survey of the optimal ventilation rate and the permissible CO2 concentration in the saloon (전동차 실내의 적정 환기율 및 이산화탄소 농도 기준치에 관한 고찰)

  • Cho Yong-Sung;Kang Seok-Teak;Park Young-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.312-317
    • /
    • 2005
  • Electric Multiple Unit is one of the major mass public transportation systems and passengers are under the influence of indoor air quality such as air temperature, relative humidity and concentration of CO2 gas. Therefore ventilation system of Electric Multiple Unit should be designed for both healthy and comfortable environments. We survey the optimal ventilation rate and the permissible CO2 concentration in the saloon with the consideration of the cooling and heating capacity and fresh air induced from tunnel.

  • PDF

An Experimental Study on the Ventilation performance in a Test Chamber and Office Room (모형실과 실공간에서의 환기성능에 관한 실험적 연구)

  • Yoon, Suk-Goo;Ku, Jae-Hyun;Yun, Ok-Chun;Han, Jung-Gun;Lee, Jae-Keum;Cho, Min-Chul;Kang, Tae-Wook;Lee, Kam-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.520-525
    • /
    • 2000
  • This research is to analyze the ventilation performance of mechanical ventilation systems for indoor air quality control and management. A ventilation performance with supply sites is evaluated in a test model chamber and office room. A $CO_2$ gas as a tracer gas is used to measure the ventilation performance. The ventilation performance is found to increase with increased the ventilation rate. The ventilation performance is analysed with 55% at the supply air of 570 lpm and with 20% at the supply air of 100 lpm in a test chamber. The ventilation performance is better than 15% comparing with natural decay at the supply of 570 lpm in office room.

  • PDF

Unsteady Numerical Simulation on the Ventilation in a Long Rail Tunnel (장대터널내 열차운행시 환기에 대한 비정상 수치해석)

  • Hur, Nahm-Keon;Kim, Wook;Kim, Sa-Ryang;Cha, Chul-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.448-454
    • /
    • 2001
  • In the present study, the transient axi-symmetric numerical simulation of traffic ventilation induced by a train running through a 15.6km-long tunnel is performed by using over 100,000 computational cells. With train running, three cases of ventilation schemes are simulated, which are the case of ventilation fans turned on, the case of no fan but ventilation shafts open, and the case of no fan and no shaft. Results of the ventilation flow rate are pressure transients are compared for the cases considered.

  • PDF

An Experimental Study on the Effect of Longitudinal Ventilation on the Variation of Burning Rate in Tunnel Fires (터널 화재시 종류식 환기가 연소율 변화에 미치는 영향에 관한 실험적 연구)

  • Yang Seung Shin;Kim Sung Chan;Ryou Hong Sun
    • Tunnel and Underground Space
    • /
    • v.15 no.1 s.54
    • /
    • pp.55-60
    • /
    • 2005
  • In this study, the 1/20 reduced-scale experiments using Froude scaling were conducted to investigate the effect of longitudinal ventilation on the variation of burning rate in tunnel fires. The methanol square pool fires with heat release rate ranging from 3.57 kW to 10.95 kW were used. The burning rate of fuel was obtained by measured mass using load cell and temperature distribution were measured by K-type theomocouples in order to investigate smoke movement. The wind tunnel was connected with one side of the tested tunnel, and logitudinal ventilation velocity in the tested tunnel was controlled by power of the wind tunnel. In methanol fire case, the increase in ventilation velocity decreased the turning rate due to the direct cooling of fire plume. For the same dimensionless velocity(V), homing rate decreased as the size of pool fire increased.

An Experimental Study on the Ventilation velocity of the Variation of Burning rate in Tunnel Fires - Heptane pool fire case (터널 화재시 배연속도가 연소율변화에 미치는 실험적 연구 - Heptane 풀화재 경우)

  • Ryou, Hong-Sun;Yang, Seung-Shin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.2
    • /
    • pp.109-117
    • /
    • 2005
  • In this study, the 1/20 reduced-scale experiments using Froude scaling were conducted to investigate the ventilation velocity of the variation of burning rate in tunnel fires. The heptane square pool fire with heat release rate ranging from 3.71~15.6 kW were used. The burning rate of fuel was obtained by measuring mass using load cell and temperature distributions were measured by K-type theomocouples in order to investigate smoke movement. The ventilation velocity in the tested tunnel was controlled by inverter of the wind tunnel. In heptane pool fire case, the increase in ventilation velocity incresed the burning rate due to the direct supply of oxygen to the fire plume. For the same dimensionless velocity($\bar{V}$), burning rate increased as the size of pool fire decreased.

  • PDF

Comparison of the PMV and $CO_2$ concentration Characteristic in the Lecture Room with a Different Airflow rate of the Ventilation System and Heating System for heating season (강의실에서 환기시스템과 난방시스템의 풍량에 따른 PMV와 $CO_2$ 농도 특성 비교)

  • Han, Chang-Woo;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.411-416
    • /
    • 2006
  • In this paper, we performed the experimental and numerical study on the thermal comfort(TC) and indoor air quality(IAQ) in the lecture room with a different airflow rate of the ventilation system and heating system for heating season. Through the experimental results, we found out that there was considerably difference of the PMV but there was little difference of $CO_2$ concentration with a different heating system. From a numerical results, the best operating condition was that discharge airflow rate of SAC is 29 CMM and supply airflow rate of the ventilation system is 1,200 CMH from a viewpoint of TC and IAQ.

  • PDF

A study on the effects of exhaust emission standards on the required ventilation rate in vehicle tunnels (차량 배출가스 규제기준이 소요환기량에 미치는 연구)

  • Kim, Hyo-Gyu;Ryu, Ji-Oh;Song, Seog-Hun;Jung, Chang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.409-420
    • /
    • 2017
  • The amount of ventilation required in making the tunnel ventilation plan is an important factor for determining the capacity of the ventilation system. The amount of pollutant emission for each type of vehicle (basic emission amount for the design of ventilation volume) for estimating the required ventilation amount is based on the 'Standard for Allowing the Emission for the car manufacturing', proposed by Ministry of Environment. However, in 2013, the Ministry of Environment announced the 'Regulations on the calculation method of total emissions from vehicles' as a regulation for calculating the pollutants emitted from vehicles. In this regulation, there are the 'Emission factors for each type of vehicle'. Therefore, it is necessary to review the application of the Regulation to the estimation of the required ventilation volume for the road tunnel. In this study, the influence of the strengthened emission regulation in 2015 caused by the case of manipulation of emission volume for the diesel vehicle on the calculation of the required ventilation volume in the road tunnel has been checked. In addition, in this study, the required ventilation volume calculated according to the Standard for Allowing the Emission for the car manufacturing revised by Ministry of Environment and "Emission factors for each type of vehicle" and that calculated according to the EURO emission standard were compared for analysis. This study has implications that it provides the basic design data for calculating the reasonable ventilation capacity of the ventilation system based on the ground for calculating the required ventilation volume.

A Study of Efficient Ventilation System in Deep Mines (심부 광산의 효율적 환기 시스템에 관한 연구)

  • Song, Doo-Hwan;Kim, Yun-Kwang;Kim, Teak-Soo;Kim, Sang-Hwan
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.168-174
    • /
    • 2016
  • The working environment is deteriorated due to a rise in temperature of a coal mine caused by increase of its depth and carriage tunnels. To improve the environment, the temperature distribution resulted by using the fan type ventilation system aiming for the temperature drop is calculated by using a fluid dynamic analysis program. The analysis shows that A coal mine needs 6,152 m3 min-1 for in-flow ventilation rate but the total input air flowrate is 4,710 m3 min-1, 1,442 m3 min-1 of in-flow ventilation rate shortage and the temperature between the carriage tunnel openings and the workings with exhausting ventilation system type is 2~3 ℃ less than that with blowing ventilation system type. The exhausting ventilation system type would be more effective than blowing ventilation system when the distance between the carriage tunnel openings and the workings is relatively far.