• Title/Summary/Keyword: Ventilation hood

Search Result 70, Processing Time 0.025 seconds

Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station (대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구)

  • Jang, Yong-Jun;Lee, Ho-Seok;Park, Duck-Shin
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.579-587
    • /
    • 2012
  • Shin-gumho station in Seoul underground subway have been selected to be experimentally investigated and analyzed for the real air supply & exhaust capacity compared to the original capacity of ordinary and emergency condition. The depth of Shin-gumho station is 43.6m which consists of the island-type platform ($8^{th}$ floor in underground) and a two-story lobby (first & second floor in underground). An emergency staircase connects between the platform and the lobby. Hot-wire anemometer, capture hood, wind vane & velocity meter and data acquisition systems are employed to perform the automatic measurement in this experiment. For ordinary case, air supply and exhaust capacity in the lobby were reduced by 34% and 46% compared to the original capacity, respectively. Air supply and exhaust capacity in the platform were reduced by 66% and 38%, respectively. For emergency case, air supply in the lobby was reduced by 42% and air exhaust in the platform was reduced by 28% compared to the original capacity. Therefore, air pollution in the station is expected to be worse in the ordinary environment and smoke control capability in the platform will be weakened in case of fire emergency.

Evaluation of Air Contaminants Concentrations and Ventilation Systems in Governmental Agency and University Laboratories (국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가)

  • Ha, Ju-Hyun;Shin, Yong-Chul;Lee, Hyun-Seok;Paik, Samuel Y.;Yi, Gwang-Yong;Lee, Byeong-Ku
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • This study was conducted to compare the concentration of various air contaminants in nine different laboratories during routine activities. Volatile organic compounds (VOC) were sampled and analyzed using NIOSH Method 1500 and asbestos fibers were sampled and analyzed using NIOSH Method 9002 and 7400. Detectable levels of acetone, toluene and ethanol were found in all the laboratories and xylene and n-hexane were detected in eight of the nine laboratories. All the VOC concentrations were well below the Korean Ministry of Labor's Exposure Limit and American Conference of Governmental Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs). Total VOC concentrations at the university laboratories were significantly higher than those at governmental agency laboratories. Airborne fiber concentrations were below 0.01 fibers/cc, while the concentration of chrysotile was 2% in insulation materials sprayed on the ceiling of one laboratory. While all the governmental agency laboratories (n=4) had fume hoods, two out of the five university laboratories did not have fume hoods. The capture velocity of half of the fume hoods were below the maintenance standard(0.4 m/sec). In conclusion, the study suggests that the current controls in place at both university and government agency laboratories are not sufficient in limiting exposure to harmful chemicals to non-detectable levels, though they appear to be adequate in protecting workers to levels below applicable occupational exposure limits. The study also suggests that researchers working in university laboratories may be exposed to greater levels of contaminant than those working in government agency laboratories.

Calibration and Performance Test of Hot-wire Anemometers by Using a Calibration Wind Tunnel (풍동장치를 이용한 열선풍소계의 보정 및 실태 평가)

  • Ha, Hyun-Chul;Kim, Tae-Hyeung;Kim, Eun-A;Kim, Jong-Chul;Oh, Jung-Ryng;Jung, Ho-Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.110-122
    • /
    • 1999
  • Hot-wire anemometers are most commonly used in measuring hood capture velocities due to their accuracy and convenience. But it was questionable that the anemometers being used in the field are accurate enough for the purpose of measurements. To answer this ques tion, a calibration wind tunnel was newly devised and tested. Subsequently, 53 hot-wire anemometers being currently used in the field were tested to evaluate the accuracy of anemometers. The average error was 16.93% while the average errors in the low (0.5~5m/s) and high (5~20m/s) velocity range were 17.40% and 16.45%, respectively. Most of anemometers underestimated the true velocities. It might be due to the contamination of hot-wire, resulting in the slow heat transfer between the sensor and air flow. Astonishingly, 16 of 53 anemometers were out of order due to the malfunctioning of zero adjustment control, power supply, display panel and sensor. It is desirable to calibrate periodically and clean the sensor after using in the dirty environment.

  • PDF

Exposure Characteristics of Particles during the After-treatment Processes of Aluminum Oxide Fibers and Nickel Powders (산화알루미늄 섬유와 니켈분말 후처리공정에서 입자의 노출특성)

  • Kim, Jong Bum;Kim, Kyung Hwan;Ryu, Sung Hee;Yun, Seong-Taek;Bae, Gwi-Nam
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.225-236
    • /
    • 2016
  • Objectives: Nanomaterials have been used in various fields. As use of nanoproducts is increasing, workers dealing with nanomaterials are also gradually increasing. Exposure assessments for nanomaterials have been carried out for protection of worker's health in workplace. Exposure studies were mainly focused on manufacturing processes, but these studies on after-treatment processes such as refinement, weighing, and packing were insufficient. So, we investigated exposure characteristics of particles during after-treatment processes of $Al_2O_3$ fibers and Ni powders. Methods: Mass-production of Ni powder process was carried out in enclosed capture-type canopy hood. In a developing stage, $Al_2O_3$ was handled with a local ventilation unit. Exposure characteristics of particles were investigated for $Al_2O_3$ fiber and Ni powder processes during the periods of 10:00 to 16:00, 20 May 2014 and 13:00 to 16:00, 21 May 2014, respectively. Three real-time aerosol instruments were utilized in exposure assessment. A scanning mobility particle sizer(SMPS, nanoscan, model 3910, TSI) and an optical particle counter(OPC, portable aerosol spectrometer, model 1.109, Grimm) were used to determine the particle size distribution in the size range of 10-420 nm and $0.25-32{\mu}m$, respectively. In addition, a nanoparticle aerosol monitor(NAM, model 9000, TSI) was used to measure lung-deposited nanoparticle surface area. Membrane filters(isopore membrane filter, pore size of 100 nm) were also used for air sampling for the FE-SEM(model S-5000H, Hitachi) analysis using a personal sampling pump(model GilAir Plus by 2.5 L/min, Gilian). Conclusions: For Ni powder after-treatment process, only 27% increase in particle concentration was found during the process. However, for $Al_2O_3$ fiber after-treatment process, significant exposure(1.56-3.34 times) was observed during the process.

Development of the Hospital Foodservice Facility Evaluation tools based on the General HACCP-based Sanitation Standards and Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설ㆍ설비 위생관리 점검도구 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.3
    • /
    • pp.339-353
    • /
    • 2003
  • The rapid increase in food borne illness outbreaks in Korea has been one of the major threats to the Nation's Health. Foodservice establishments have been identified as the major place for these outbreaks, mainly due to the lack of sanitary management and sanitary facility management practices. The purposes of the study were to develop hospital foodservice facility evaluation tools, based on the general HACCP-based standards and guidelines, for hospital food service establishments, to ensure the safety of these foodservices and to reduce the risk of food home illness. The scope of this study included: 1) an assessment of the current foodservice sanitation practices and managements for 6 general hospitals, with more than 400 beds, and 3 general hospitals, with less than 400 beds; 2) the development of foodservice establishments sanitation evaluation tools and sanitation standards, based on the HACCP system. The survey data showed varied results between the hospitals surveyed. Most of the hospital foodservice operations had many problems with ventilation and the plumbing. The total dimensional mean scores for the hospitals with more than 400 beds and less than 400 beds were 31.5 and 27.0, respectively. The highest dimension scores were for the water supply facility and lighting, with the lowest for insect and rodent control and toxic materials management. The levels of the mean scores were very low, especially for the general hospitals with less than 400 beds. These low mean scores may have arisen from critical problems within the hospital foodservice operations. The most needed facility management items for improvement were: storage shelf should be spaced 6 inches from the floor and walls, the use of three compartment sinks, utility sinks and cleaning facilities, with a floor drain for cleaning mops or liquid wastes, a ventilation hood designed to prevent dripping onto food, cooking facilities should be disassembled for washing and sanitizing, a separated hand washing sink and a sanitized food board for each area should be provided, all toxic material must have warning labels attached, and be stored in an area away from food preparation under padlock. The evaluation tool consisted of 14 dimensions, with 65 check-off items. The results of this study will provide basic facilities' guidelines to regulators, or foodservice industry personnel, wishing to build, or expend, and establish an efficient flow of food. As a result, food borne illnesses will be effectively prevented, and the Nation's health will be promoted for the development of their own sanitation standards, with a checklist for the safe production of foods.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

A Study on the Removal Efficiency of Harmful Pollutants in the Cooking Chamber (조리실내의 유해오염물질 제거율에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.149-156
    • /
    • 2016
  • The purpose of this study is to reduce the contaminants (total volatile organic compounds (TVOCs), fine particle, odor and total airborne bacteria) during cooking process in cooking chamber, and to decrease the health damage in indoor space that has bad work environment. In order to solve the shortcomings of existing air purifiers and remove all kinds of pollutants effectively, this study focused on the development of indoor air purifiers which are made of bar type. Bio-ceramics filter which combines activated carbon and loess. The air cleaners developed with 4 measuring items including TVOCs, particulate matter, complex odor and total airborne bacteria were measured comparing their pre-service test to their post-service test after a period of time. The measured results showed higher removal efficiency of 91.02% as the concentration of TVOCs was reduced from $2,500{\mu}g/m^3$ to $223{\mu}g/m^3$. Second, the particulate matter removal ratio was 97.51% efficient with average concentration of $26.68{\mu}g/m^3$. Third, the odor showed 95.20% reduction as air dilution ratio averaged out at 144. Last, total airborne bacteria was eliminated by over 94% showing the changeable concentration from $787{\sim}814CFU/m^3$ to $47{\sim}40CFU/m^3$. In addition, the removal rate of harmful pollutants is excellent, and it is expected that the environment of the existing poor cooking room will be greatly improved by using the developed air purifier in combination with the ventilation device and the stove hood.

Determination of HONO Concentration and Investigation on Its Formation Mechanism Using a Continuous Measurement System in Indoor Environment of an Apartment (아파트 실내 환경에서 실시간 측정시스템을 활용한 HONO 농도 측정 및 생성기작 연구)

  • Park, Seung-Shik;Hong, Jin-H.;Lee, Jai-H.;Kim, Young-J.;Cho, Sung-Y.;Kim, Seung-J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.16-29
    • /
    • 2008
  • Nitrous acid (HONO) can be produced by heterogenous reactions of nitrogen dioxide on surface materials and direct emission from combustion sources. However, a little is known of indoor HONO levels or the relationship between residential HONO, NO, and $NO_2$ concentrations in occupied houses. Therefore, we measured simultaneously NO, $NO_2$, and HONO concentrations in living room of an apartment using continuous analyzers to study the production of HONO (June $22{\sim}30$, 2006). The 4-min average concentrations of indoor NO, $NO_2$, and HONO were 4.3 (range: $0.4{\sim}214.3$), 10.3 ($2.0{\sim}87.3$), and 1.8 ppb ($0.3{\sim}7.7$), respectively. Peak levels of HONO up to 7.7 ppb and 24-hr averages as high as 1.7 ppb were measured. In agreement with previous studies, indoor HONO concentrations increased during operation of an unvented gas range. Examination of the observed kinetics suggests that the secondary production of indoor HONO, possibly as a result of heterogeneous reactions involving $NO_2$ and $H_2O$ is associated with $[NO_2]^2[H_2O]\;(r^2=0.88)$ rather than with $[NO][NO_2][H_2O]\;(r^2=0.75)$. Three combustion experiments at nighttime were also carried out to investigate the effects of vented combustion on the HONO, NO, and $NO_2$ concentrations. It was found to release HONO for $10{\sim}15$ minutes after NO and $NO_2$ source was turned off, and peak values were finally attained. Compared to unvented combustion, peak $NO_2$ and HONO concentrations were 3.2 and 2.0 times lower at weak vented combustion (air flow: $340\;m^3/hr$) and 4.9 and 2.4 times lower at strong vented combustion (air flow: $540\;m^3/hr$), respectively, emphasizing importance of operating ventilation hood fan during combustion to improve indoor air quality.

Preferences of Stroke Patients for Kitchen Environment in Residential Space (주거공간의 부엌 환경 특성에 대한 뇌졸중 환자의 선호)

  • Baek, Da-Rae;Jung, Yeon-Jin;Kang, Suk-Gu;Kim, Hee-Jung;Lee, Chun-Yeop
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 2014
  • Objective : The purpose of this study was to investigate the preferences of kitchen environment for stroke patients. Methods : The subjects of this study were 97 who have experience in rehabilitation therapy at hospitals in Busan. A questionnaire was distributed and collected from February 24th to March 13th, 2014. Descriptive statistics of frequency Study were used to analyze data. Results : First, the subjects demand for improvement that use a chair for work and install non-slip tiles. Second, they preferred the non-slip mat, boilers in heating equipment, drawer storage, L-shaped safety handle, adjustable sink of the height, automatic cutout of gas leak, faucet of touch-sensitive type, ㄷ-shaped kitchen and the ceiling-type hood in ventilation system. Third, they need kitchen items such as the sink self coming down, scissors for slices and knife to avoid hand injury. Conclusion : This study would contribute to kitchen environment for fall prevention and ease in use.

  • PDF