• Title/Summary/Keyword: Ventilation hood

Search Result 70, Processing Time 0.022 seconds

A Study on the Occurrence Character of Contaminant in the Kitchen that Use Gas Fuel (가스를 연료로 사용한 주방에서의 오염물질 발생 특성에 대한 연구)

  • 박명길;함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2001.11a
    • /
    • pp.77-82
    • /
    • 2001
  • This paper is contents that measure the ventilation rates and temperature by driving condition of exhaust fan, vapor, contaminant occurrence amount of carbon dioxide etc. In kitchen of apartment house. The ventilation rates in the apartment kitchen measured by Tracer Gas Method. And, temperature of when cook by gas table hood lower part 10cm and floor upside 10cm of kitchen central part, 120cm, 210cm heights measure. As ventilation rates measurement result, ventilation number of times was 0.7(number of times/hour) when did not to operate exhaust fan. but we were measured by 2.3(number of times/hour) when drove strongly. As temperature measurement result at cooking by gas table, temperature showed highest in hood lower part 10cm of case that do not operate exhaust fan. Temperature at kitchen central was most low in 10cm height in talc floor, and 210cm were measured highest. Concentration of carbon dioxide is very high by 4,350ppm after measurement time 10 minutes in state who do not operate exhaust fan at cooking by gas table.

  • PDF

A Study on Ventilation Characteristics of LNG Carrier Hood room by PIV and CFD (PIV와 CFD에 의한 LNG선박의 Hood room 환기특성에 관한 연구)

  • Cho, D.H.;Kim, D.C.;Kim, M.E.;Lee, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.673-679
    • /
    • 2000
  • LNG Carriers are currently known as sole commercial means of shipping natural gas on the sea. They are designed to proven dangerous explosion for shipping a lot of gas over long distance. In this study. In this study, a scaled model chamber was made to investigate ventilation characteristics of the hood room in LNG carrier. Experimental study was performed in model using visualization equipments with laser apparatus and image intensifier CCD camera gated by an AOM controller Twelve different kinds of measuring area were selected as experimental condition. Instant simultaneous velocity vectors at whole field were measured by using 2-D PIV system which software adopts two-frame grey-level cross correlation algorithm. To look into stagnation area of hood room for LNG carrier, a three-dimensional numerical simulation with standard ${\kappa}-{\varepsilon}$ model was carried out by using PHOENICS for three kinds of Reynolds number, $6.5{\times}10^3$, $9.7{\times}10^3\;and\;1.29{\times}10^4$, based on the cavity inlet velocity and cavity height. The flow pattern showed the large scale counter-clockwise forced-vortex rotated at center area, small eddies at each corner and stagnation area located at left-back upper side of model.

  • PDF

A Study on Mechanical Ventilation Characteristics in Cargo Handling Area of Tanker (유조선 화물취급구역내 동력환기특성에 관한 연구)

  • 조대환
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.7 no.1
    • /
    • pp.15-23
    • /
    • 2001
  • In regulation of IGC code 12.1 mechanical ventilation should be arranged to ensure sufficient air movement through the space to avoid the accumulation of flammable or toxic vapours and ensure a safe working environment, but in no case should the ventilation system have a capacity of less than 30 changes of air per hour baed upon the total volume of the space. In this study, a scaled mode chamber was constructed to investigate the ventilation characteristics and stagnation area in the hood room of LNG carrier and pump room in tanker. An experimental study was performed on the model by using visualization equipment with a laser apparatus and an image intensifier CCD camera. Twelve different kinds of measuring areas were selected as the experimental condition. Instant simultaneous velocity vectors in the whole fields were measured by a 2-D PIV system A three-dimensional numerical simulation was also carried out for three different Reynolds numbers. Then the CFD predictions were discussed with the experimental results. The results show the spiral L-shape flow that moves from the opening on the left wall diagonally to the upper right part dominates the ventilation structure. The stationary area of hood room in the velcoity distributions was located in the upper left stern part.

  • PDF

Noise Reduction of Range Hood in Kitchen Ventilation System (주방 환기 시스템에서 렌지 후드의 소음 감소 방안)

  • 최영석;김철호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.848-851
    • /
    • 2004
  • This paper studied a method for minimizing the noise level emitted from range hoods. Range hoods were used for discharging various hazardous materials generated during household cooking to the outdoors, thus preventing them from being diffused through rooms in the house since they are the main cause of air pollution within dwellings. This study assumed that static pressure was not applied at the discharge outlet of the range hood. As such, the range hood was installed on the wall without the use of a connecting duct or other connectors attached to its discharge outlet. The vibration having the greatest influence on the noise level was determined by measuring the vibration at the front side of the hood where the acoustic omission was at its maximum. A method was then proposed to reduce the noise by simply suppressing the vibration at the vibrating part.

  • PDF

Additional Improvement and Evaluation of Exhaust Ventilation Systems at Small and Medium Sized Enterprise (중.소규모 사업장의 국소배기장치 설치 실태와 문제점 및 개선방안)

  • Lim, Seong-Keun;Park, Doo-Yong;Kim, Won-Ki;Kim, Soo-Geun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Objectives : The purposes of this study were to evaluate exhaust ventilation systems(EVSs) and to suggest problems and improvements. Methods : For 50 small and medium-sized enterprises, we carried out evaluation of EVSs. We evaluated hoods with smoke tester and measurement of capture velocity. In addition, we used several indicators for performance evaluation designed in this study. Results : 1. Based on the smoke flow pattern and the criteria of occupational health and safety act, 67.8% of hoods were rated 'good' level at smoke test whereas 26.3% were rated 'good' level at measurement of capture velocity. 2. 29.3% of hoods, of which ratio of measured actual air flow at hood(Qah) to required ideal exhaust air flow at hood(Qih) was 1 or more, were rated 'good' level. 3. The % of EVS, of which ratio of measured actual air flow at stack(Qast) to total required ideal exhaust air flow at hood(Qith) was 1 or more, was 29.0%. 4. For the ratio of measured Qast to existing air flow at fan(Qfan), only 5% of EVSs were 1 or more and 26.0% were 0.8 or more but less than 1.0. 5. For the ratio of measured Qast to total measured actual exhaust air flow at hood(Qath), 74.0% were 0.8 or more but less than 1.0. 6. The percentage of EVS, of which ratio of total measured Qath to existing Qfan was 0.8 or more, was 19.0%. 7. The percentage of EVS, of which ratio of total measured Qath to total required ideal exhaust Qith was 1 or more, was 26.0%. 8. For the comprehensive evaluation indicators designed in this study, 29.0% were 0.8 or more. Conclusions : We found that few exhaust local ventilations at small and medium-sized enterprises were rated 'good' level and that most exhaust local ventilations had 'poor' design and installation. Therefore, relevant professional manpower and enterprises have to construct exhaust local ventilation where it is needed, and technical guidance and economic support are needed to improve 'poor' exhaust local ventilation after self-evaluation.

A Study on the Reduction of Entry Loss by Inner Structure in Square Hood in Industrial Ventilation System (산업환기시설에서 사각형 후드의 내부 설치에 의한 유입손실 감소에 관한 연구)

  • Bae, Hyun-Joo;Yang, Won-Ho;Kim, Jong-Oh;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.27-34
    • /
    • 2003
  • An objective of local exhaust hood design is to design the hood to operate as efficiently as possible. The greatest loss normally occurs at the entrance to the duct, due to the vena contracta in the throat of the duct. This can be accomplished by minimizing the loss that results from the vena contracta. There have been little studied to be cost-effective approach as installing simple instrument inside the throat of the hood. The aims of this paper were to minimize entry loss using inner square, and to measure the effect of inner square when installed inside hood throat. The results of this study were as follows; First, the magnitude of vena contracta could be considered as the difference between direct measured velocity and calculated velocity, which is from Bernoulli theory. In circle hood, calculated velocity and direct measured velocity were 10.7m/sec and 10.3n/sec, respectively. And the calculated velocity and direct measured velocity in square hood were 7.7m./sec and 6.5m/sec, respectively. Second, effect of inner square by width was carried out. The widths of inner square were L/1(18cm), L/2(9cm), L/3(6cm) and L/6(3cm). In case inner square was installed with 3cm width, the entry of coefficient was 0.93, comparing with 0.85 of entry of coefficient of general hood. Third, effect of inner square by distance from hood inside surface to inner square was carried out. The distances were L/3(6cm), L/6(3cm), L/9(2cm) and L/l8(1cm). In case the distance was 3cm the best efficiency was shown (Ce= 0.93). Fourth, effect of inner square by location from hood entry to duct inside was carried out. The locations of inner square were entry(0cm), L/6(3cm), L/3(6cm), L/2(9cm) and L/l(12cm). In case the location was 0cm, 3cm and 6cm the entry of coefficients were 0.93, 0.92 and 0.90, respectively.

A Research on the Noise Reduction of a Kitchen Ventilation System and the Prediction of Sound Distribution in a Kitchen and Room (주방환기 시스템의 소음 저감과 실내 음장분포 예측에 관한 연구)

  • Song, Hwa-Young;Lee, Dong-Hoon;Lee, Chang-Kun;Kim, Dong-Yun;Hong, Byung-Kuk
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.494-499
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which harsh noises are generated. Though the harsh noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level emitted from the range hood was decreased more than 10dB(A) in all 1/3 octave bands due to the effect of noise reduction by perforated plate systems.

  • PDF

An active system for unnecessary noise reduction in kitchen range hoods

  • Kim, Eunhee;Jang, Jaechun;Lim, Changmok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.3
    • /
    • pp.91-96
    • /
    • 2016
  • We have surrounded undesired living noises in our life. One of biggest noises coming out of range hood during cooking in the kitchen. A range hood is one of the most important appliances in the kitchen because it ventilates polluted air out during cooking, and maintains air quality in the kitchen. But current kitchen range hoods bring up some issues; First, the range hoods consume massive amount of standby power not in use condition. Second, current models have designed manual fan operating system with sudden onset of noise with starting. In this paper, we propose an auto control system entire processes from air ventilation to noise reduction. Our system is consist of three parts (Eco-sensors pack, Main Controller and Active Noise Controller); Eco-sensors pack detects air pollution of kitchen areas and sends the detection values to Main Controller. Main Controller determines operation of range hood by detected values. Active Noise Controller is located inside of the range hood. It received starting signals from Main Controller which elicits degrees of polluted air condition and fan operating speed from 1 to 3. Once Active Noise Controller detected the signals, it runs a ventilating fan until new value from Main Controller becomes 0. while the range hood works, A noise cancellation algorithm inside of Active Noise Controller become activated to reduce levels of noise. As a result, the proposed system clearly shows reduction in power consumption include standby power and decreases in levels of noise.

A Study on Worker Exposure to Hexavalent Chromium in Plating 0peration (중소기업 도금공정에서의 6가 크롬 폭로에 관한 연구)

  • Cheong, Hoe Kyeong;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.152-165
    • /
    • 1993
  • This study was performed at eleven small-sized plating factories located in Seoul, Incheon, Ansan, and Taejeon from July 21 to October 6, 1992. The major objectives of this study were to evaluate worker exposure to hexavalent chromium and local exhaust ventilation (L.E.V.) systems at the chromium plating operations. The most suitable L.E.V. systems for chromium plating tanks were designed as examples for recommendation to the industry. The results are summarized as follows. The range of chromium plating operations investigated included decorative, hard, and black chromium plating on several kinds of parts. Most of plating tanks were not equipped with proper control methods against emission of hexavalent chromium mists and workers were not wearing appropriate personal protectives. The ariborne hexavalent chromium concentrations showed an approximate lognormal distribution. The geometric means of both personal and area samples were within the Korean and ACGIH standards, $50{\mu}g/m^3$. However, in comparison with the NIOSH criterion, $1{\mu}g/m^3$, the geometric means of personal samples at two factories and the geometric means of area samples at two factories exceeded it. The geometric means of personal and area samples of high exposure groups (above the NIOSH criterion) were 7 and 27 times higher than those of low exposure groups (below the NIOSH criterion), respectively. The L.E.V. systems of high exposure groups were improperly designed, and the factory with the highest exposure level had no L.E.V. systems at all on chemical etching process. Whereas at factories of low exposure groups, mist control methods such as mist suppressants, tank cover, and/or auxillary L.E.V. systems were added to L.E.V systems. The evaluation of L.E.V. systems showed that there was no chromium plating operation satisfying the ACGIH criteria for capture velocity, slot velocity, and exhaust rate simultaneously. To increase performance of L.E.V. systems, it must be designed to minimize the impact of boundary layer separation. Push-pull ventilation hood and downward plenum ventilation hood were suggested for the Korean industry.

  • PDF