• 제목/요약/키워드: Ventilation gas

검색결과 411건 처리시간 0.027초

The effect of ventilation on reducing the concentration of hazardous substances in the indoor air of a Korean living environment

  • Kim, Hyunjoo;Kim, Jin Seog;Lee, Jongman;Kim, Dalho
    • 분석과학
    • /
    • 제33권1호
    • /
    • pp.49-57
    • /
    • 2020
  • Controlling the quality of indoor air is important in order to maintain a healthy life. In this study, we investigated the correlation between the hazardous substance concentration of indoor air and circulation based on different ventilation methods in the apartment, which is one of the representative housing types in Korea. As target substances, we considered the hazardous substances which are generated during the cooking process and radon gas which is originated from building materials. We measured the concentrations of carbon dioxide and fine particles in relation to type of food and ventilation methods in order to determine the change in the concentration levels of hazardous substances which are generated during the cooking process. On the other hand, we measured the concentration of radon gas before and after letting fresh air into a room through windows in order to determine the change in the concentration level of radon gas which is originated from building materials. The results show that turning on the ventilation fan plays a major role in reducing the concentration levels of hazardous substances in the kitchen, and that it is more effective to turn on the ventilation fan during cooking than after cooking to prevent the diffusion of hazardous materials produced by cooking through the indoor air. Also, the results indicate that letting fresh air into a room through windows more than one time a day is necessary to reduce the concentration level of radon gas in the room to safe concentration range.

도로터널용 전기집진시스템 개발 (Development of Road Tunnel Ventilation System with Electrostatic Precipitator)

  • 김종률;원종웅
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.80-83
    • /
    • 2008
  • As SOC (Social Overhead Capital) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, we may need to introduce a compulsory ventilation system as well as natural ventilation mechanism. The natural ventilation mechanism is enough for short tunnels, meanwhile longer tunnels require a specific compulsory ventilation facility. Many foreign countries already have been devoting on development of effective tunnel ventilation system and especially, some European nations and Japan have already applied their developed tunnel ventilation system for longer road tunnels. More recently, as the quality of life improved, our concerns about safety of driving and better driving environment have been increased. In order to obtain clearer and longer driving view, we are more interested in EP tunnel ventilation system in order to remove floating contaminants and automobile exhaust gas. Evan though it's been a long time since many European countries and Japan applied more economical and environment-friendly tunnel ventilation system with their self-developed Electrostatic Precipitator, we are still dependant on imported system from foreign nations. Therefore, we need to develop our unique technical know-how for optimum design tools through validity investigation and continuous possibility examination, eventually in order to localize the tunnel ventilation system technology. In this project, we will manufacture test-run products to examine the performance of system in order to develop main parts of tunnel ventilation system such as electrostatic precipitator, high voltage power generator, water treatment system, etc.

  • PDF

지하 발전소 환기설비에 대한 안전성 평가 (The Safety Assessment for Ventilation Facilities of Underground Power Plant)

  • 고원경;강승규;정영대;김영구
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.331-332
    • /
    • 2014
  • Underground power plant is required the strict safety management and safety assessment. Because it is the high risk of explosion by characteristic of enclosed space. In case gas leak of enclosed space, the ventilation facilities is very important in order to prevent explosion by the maintain less than the LEL(lower explosive limit). Thus, Through a safety assessment of ventilation volume is to reduce the risk for ventilation facilities in Underground power plant.

  • PDF

휴대용 가스렌지 연소에 의한 공기오염물질의 발생량 및 실내환경의 필요 환기량 (Source Emission Rate on Air Pollutants from Portable Gas Range and Optimal Ventilation Rate in Indoor Environment)

  • 임성국;김영희;양원호
    • 한국환경보건학회지
    • /
    • 제33권2호
    • /
    • pp.92-97
    • /
    • 2007
  • A series of source tests were conducted to characterize emissions of nitrogen oxide(NOx, NO, $NO_2$), carbon mon oxide(CO), carbon dioxide$(CO_2)$ and total VOCs from portable combustion devices in steady-state using well-mixed chamber. Since use of portable gas range is widespread in houses and restaurants in Korea, it is important to characterize the emission of air pollutants and suggest optimum ventilation rate. Ranges of emission rates of air pollutants from portable gas ranges were $NO \;0.551\sim0.939mg/hr,\;NO_2\;0.354\sim1.080mg/hr,\;NO_x\;1.207\sim1.631mg/hr,\;CO\;1.389\sim4.21mg/hr,\;CO_2\;2426.823\sim2973.495mg/hr$, and VOCs $0\sim0.119mg/h$. Mean of personal exposure and indoor environment level of $NO_2$ by combustion of portable gas range were 74.7 ppb and 65.4 ppb, respectively, suggesting persons using portable gas range in houses and restaurants might be highly exposed. Required ventilation rate to control the air pollutants emitted from portable gas range was maximumly $3.131m^3/hr$ on the basis of $NO_2$ indoor air quality standard.

초고층 공동주택의 환기효율 개선에 관한 연구 (A Study on the Improvement of Ventilation Effectiveness in High-rise Apartment Buildings)

  • 박진철
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.87-94
    • /
    • 2006
  • The efficiency of ventilation system is one of the most important issues of designing ventilation in high-rise apartment buildings. The purpose of this study is to analyze the ventilation efficiency of ventilation system by experimental study using CO2 gas method. The results of this paper can be summarized as follows; (1) An appropriate ventilation including opening planning, mechanical and hybrid system are required. (2) The supply diffuser of ventilation system should be located near the contaminant source. (3) The return grill should be located along with supply diffuser for proper ventilation. and the return grill should be located near or right above the contaminant source. (4) However, the supply location right above the contaminant source has to be avoided. and the supply diffuser should be installed in module with return grill increase ventilation effectiveness.

공동주택의 환기방식별 다수실 환기 성능에 관한 연구 - 다수실의 환기경로 및 환기효율 - (Study on Ventilation Performance of Multi-room in Apartment - Airflow and Ventilation Effectiveness in Multi-room -)

  • 권경우;조시진;최의성;박준석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.399-404
    • /
    • 2006
  • Heating and cooling load of ventilation is a very important part of building energy saving. Improving ventilation effectiveness can save building energy consume and supply fresh air to indoor efficiently. So this study measured mulity-zone aiflow and ventilation effectiveness according to ventilation types. Result of measurement show that ventilation effectiveness is depends on ventilation system design rather than ventilation types.

  • PDF

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

미세 후두현미경술시 윤상갑상막천자를 통한 고빈도 제트환기법 (High Frequency Jet Ventilation via Cricothyroid Membrane Puncture under Microlaryngoscopic Surgery)

  • 양훈식;김용주;김춘길
    • 대한기관식도과학회지
    • /
    • 제1권1호
    • /
    • pp.109-115
    • /
    • 1995
  • High frequency Jet ventilation (HFJV) via cricothyroid membrane puncture contols frequency of ventilation as 20-200/min and persuits adequate gas exchange. HFJV was known to have advantages such as improvement of PaO$_2$, lesser barotrauma, stable hemodynamic effects, good operative field and lesser movement of head. The purpose of this study was to clarify the advantages of HFJV in cases of microlaryngeal surgery which operating time was expected even within 30 minutes. Twenty-eight patients were divided two groups : 1)control group : general endotracheal Intubation anesthesia. 2)experimental group : HFJV via cricothyroid membrane puncture with intravenous anesthesia, frequency 40/min, I/E ratio 40%, driving pressure 40 psi. We analyzed blood pressure, arterial blood gas, score of general condition and recovery time after operation. In conclusion, HFJV via cricothyroid membrane puncture had a good score of general condition and rapid recovery of consciousness, although some accumulation of P$CO_2$and elevation of blood pressure.

  • PDF

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

유해물질 제거를 위한 국소배기장치 후드의 흡입력 증가에 관한 연구 (A Study on Inhalation Force Improvements of Ventilation Hood For Removed a Pollution Source)

  • 양호동;김영선;오율권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2327-2332
    • /
    • 2007
  • This study investigates on the inhalation force improvements of hood consisted one of the local ventilation systems attached the new device named as gas-guidance-device for removed a pollution source. The numerical method applying finite element method is calculated the velocity and pressure distributions of a moving fluid at the beginning and the inside of a hood with and without the gas-guidance-device in hood. And, the experimental study is measured the wind velocity using the anemometer at the same condition of numerical study. Also, the optimum shape of gas-guidance-device which is suitable for hood shape derived from the numerical and experimental results. The results of this study is supplied the important data to an industrial field for control of a pollution source in the engineering aspect. Moreover, the introduced technique of hood attached the gas-guidance-device is very useful to remove the harmful materials such as dust and waste happened in the manufacturing factory.

  • PDF