• Title/Summary/Keyword: Ventilation conditions

Search Result 505, Processing Time 0.03 seconds

A Study on Ventilation Effectiveness in the Non-isothermal Supply using Mixing and Displacement Ventilation Systems (비등온 급기조건에서 환기방식에 따른 환기효율 특성에 관한 연구)

  • 이재근;강태욱;윤석구;구재현;한정균;조민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.739-745
    • /
    • 2001
  • The objective of this research is to analyze the ventilation effectiveness in the non-isothermal air supply using mixing and displacement ventilation systems for indoor air quality control and management. In this study, a ventilation effectiveness is evaluated in a simplified model chamber using a tracer gas technique of $CO^2$ gas injected into a supply duct as a function of ventilation rates, supply/extract sites and cooling/heating air supply. The ventilation effectiveness decreased with increasing ventilation rate on the cooling and heating conditions. And the ventilation effectiveness of case 3 (down supply and upper extract) was better thant that of case 1(upper supply and upper extract) and case 2(upper supply and down extract) with the cooling supply conditions. but for the heating supply air conditions, the ventilation effectiveness of case 2 was better than that of case 3 and case 1.

  • PDF

Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space (바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향)

  • 정광섭;한화택;홍승재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

An Experimental Study for the Improvement of Ventilation Conditions and Effectiveness in the Manufacturing Industry by Increasing the Mixing Factor (K-Factor) (혼합계수(K-Factor) 증가에 따른 사업장의 환기 조건 및 효율 개선에 관한 연구)

  • Lee, Yun-ho;Lee, Seokwon;Lee, Kyoungho;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: This study aims to identify whether ventilation conditions and their effectiveness can be significantly improved in an experimental chamber by increasing the mixing factor (K-Factor). Methods: In a chamber with a volume of $1m^3$, air velocity was measured at six different points with four roof fans in the upper part of the chamber being operated in order. The impact of the ventilation conditions was analyzed when the flow rates were increasing and the first inlet of the chamber was either open or closed. Smoke patterns were also observed at four corner points where ventilation was limited. Kruskal Wallis and Mann-Whitney tests were performed to compare air velocities measured in the chamber. Results: The air velocities measured at only the third point increased significantly from $0.03{\pm}0.03m/s$ (door open) and $0.05{\pm}0.06m/s$ (door closed) with two fans, $0.08{\pm}0.08m/s$ with three fans, and $0.09{\pm}0.09m/s$ with four fans operating (p<0.05). However, air velocities at the four corner points did not significantly increase. Smoke patters also showed that the open inlet of the chamber had no effect on improvement of ventilation conditions and effectiveness. Conclusions: In this study, the air velocities at six points in the chamber did not significantly increase despite the increase in the mixing factor and flow rates of ventilation in the controlled environment. Therefore, the inflow of outdoor air throughout an open inlet and installation of a forced ventilation system can potentially increase the indoor air velocity and improve ventilation condition without an increase in the mixing factor.

Computational study of road tunnel exposure to severe wind conditions

  • Muhic, Simon;Mazej, Mitja
    • Wind and Structures
    • /
    • v.19 no.2
    • /
    • pp.185-197
    • /
    • 2014
  • Ventilation and fire safety design in road tunnels are one of the most complex issues that need to be carefully considered and analysed in the designing stage of any potential upgrade of ventilation and other fire safety systems in tunnels. Placement road tunnels space has an important influence on fire safety, especially when considering the effect of adverse wind conditions that significantly influence ventilation characteristics. The appropriate analysis of fire and smoke control is almost impossible without the use of modern simulation tools (e.g., CFD) due to a large number of influential parameters and consequently extensive data. The impact of the strong wind is briefly presented in this paper in the case of a longitudinally ventilated road tunnel Kastelec, which is exposed to various severe wind conditions that significantly influence its fire safety. The possibility of using CFD simulations in the analysis of the tunnel placement in space terms negative effect of wind influence on the tunnel ventilation is clearly indicated.

A Study on the Ventilation Conditions for the Prevention of Spontaneous Combustion of Small Ship Engine Room (소형선박 기관실의 자연발화 방지를 위한 환기조건에 관한 연구)

  • Park, Chan-Su
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.11-19
    • /
    • 2008
  • In order to show the most suitable ventilation conditions for the prevention of spontaneous combustion of small ship engine room, We have performed CFD simulation and analyzed flow and temperature fields. The flow patterns indicated differently according to the number and location of supply and exhaust opening. The case of locating the exhaust openings at the center of left and right side ceiling to the longitudinal symmetric line were more effective to eliminate the generated heat. When the number of supply and exhaust openings were increased, the case of increasing the number of exhaust opening showed more suitable ventilation conditions. The most suitable ventilation conditions in order to prevent the spontaneous combustion of small ship engine room was predicted that the supply opening located at the center of front and after side ceiling to across symmetric line, and the exhaust opening located at the center of both side walls.

Analysis of Ventilation Rates in Residential Buildings using a Multizone Network Model (멀티존 네트워크 모델을 이용한 주거용 건물의 환기량 분석)

  • Cha, Ji-Hyoung;Park, Cheol-Hun;Kim, Yeong-Ha;Baek, Chang-In;Han, Hwa-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.45-50
    • /
    • 2005
  • The supply outdoor airflow rates are calculated and analyzed using a multizone network model in a high-rise residential apartment. The system parameters include parameters related to weather conditions, building conditions, operation conditions, and facility conditions. Simulations are conducted according to the method of design of experiments and analysis of variance is conducted to investigate the effects of parameters on ventilation rate. A correlation equation is derived to predict ventilation rates of the building depending on the various parameters.

  • PDF

Changes in Unprotonated Nicotine Concentration in Cigarette Mainstream Smoke with Three Machine-Smoking Conditions

  • Lee, Jeong-Min;Jang, Gi-Chul;Lee, John-Tae;Park, Jin-Won;Kim, Do-Yeon;Kim, Hyo-Keun;Hwang, Keon-Joong;Min, Young-Keun
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.28 no.2
    • /
    • pp.136-143
    • /
    • 2006
  • This study was conducted to determine the amount of unprotonated nicotine in cigarette mainstream smoke and to investigate its relationship to level of filter ventilation and machine smoking conditions. Unprotonated nicotine from TPM trapped on a Cambridge filter pad(CFP) was adsorbed by Carboxen/PDMS SPME fiber, thermally desorbed and determined by GC/MS. 2R4F reference cigarette, twelve commercial brands from the Korean market and five test cigarette samples, which had the same tobacco blend with different levels of filter ventilation, were analyzed for unprotonated nicotine. In commercial brands, the amount of unprotonated nicotine changed slightly depending on the pH values of smoke, and decreased as the tar level increased. filter ventilation in these commercial cigarettes was $28{\sim}80%$ and the higher filter ventilation increased relative unprotonated nicotine levels, but not significantly. However, in five test cigarettes with different filter ventilation$(0{\sim}70%)$, unprotonated nicotine levels increased almost linearly with the level of filter ventilation. Concentrations of unprotonated nicotine in mainstream smoke generally increased in order $HC\;<\;ISO\;{\leq}\;MDPH$ machine smoking conditions. The ratio of unprotonated nicotine to total nicotine among $cigarettes({\alpha}_{fb})$ increased in order RC < MDPB < ISO conditions. Concentrations of unprotonated nicotine varied with three machine smoking conditions.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

Regulating Natural Lighting and Ventilation of Residential Buildings in Hong Kong Policy Implications for High-rise, High-density Housing Environments in South Korea

  • Seo, Bokyong;Kim, Sung-Hwa;Lee, Jae-Hoon
    • Architectural research
    • /
    • v.16 no.3
    • /
    • pp.81-92
    • /
    • 2014
  • This study discusses the features of the lighting and ventilation regulations for residential buildings in Hong Kong. Given the compact built environment and public concerns about the environmental quality of housing, various lighting and ventilation regulations have been enacted in Hong Kong. The application of building regulations on the micro scale and incentive systems on the macro scale are present, and the governments' calls for more active participation of the private sector and use of the building environmental assessment tools were also noted. Unlike South Korea, however, Hong Kong was found to adopt more performance-based standards, consider the external factors of the lighting and ventilation conditions together with the indoor elements, and provide specific design guidelines. Notwithstanding the different climatic conditions and socio-political contexts of Hong Kong and South Korea, these findings provide some policy implications for the South Korean government in its efforts to achieve a healthy environment for high-rise, high-density housing. It is suggested that the South Korean government adopt more on-site measurement methods to reflect the environmental conditions accurately and broaden the scope and scale of the implementation of the lighting and ventilation regulations with more specific, practical planning and design guidelines.

Effect of Ventilation Type on the Trajectory of Coughed Particles in a Hospital Ward (실내환기 방식이 재채기 토출입자의 거동특성에 미치는 영향)

  • Kwon, Soon-Bark;Song, Ji-Han;Cho, Young-Min;Jeong, Woo-Tae;Park, Duck-Shin
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.59-67
    • /
    • 2013
  • One of purposes in this study was to confirm the behavior of coughed particles under different ventilation conditions. Three types of ventilation systems were applied for this experiment and the properties of coughed particles were measured using computational fluid dynamics (CFD) in an intensive care unit. The changes of total airborne particles for each case showed different trends according to the ventilation type and time, but the deposited particles were similar in all conditions. Although the time taken for 50% of the particles to be deposited was the fastest in case 2, the portion of deposited particles after 300 seconds was only 5% in all conditions. In case 1, a relatively small number of particles were deposited on the wall, but the particle exhaust and deposition on the occupants were the highest. In case 3, the downward ventilation was applied as that recommended by the US Center for Disease Control and Prevention (CDC) and showed different exhaust efficiencies according to the particle size.