• Title/Summary/Keyword: Ventilation capacity

Search Result 175, Processing Time 0.023 seconds

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

Experimental and Numerical Studies on Heat/Smoke Behavior due to a Fire on Underground Subway Platform (I) - Experimental Approach - (지하철 역사 승강장 화재발생시 열/연기 거동 분석을 위한 실험 및 수치 연구(I) - 실험적 접근 -)

  • Park, Won-Hee;Kim, Dong-Hyeon;Chang, Hee-Chul;Kim, Tae-Kuk
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.9-14
    • /
    • 2006
  • In this study boundary velocity which is one of the important boundary conditions for numerical simulation for subway station on fire are experimentally obtained. The tests were conducted according to its operating mode of the ventilation systems in the platform: smoke extraction ventilation mode in occurrence of fire and normal ventilation mode for air conditioning. Velocities are measured at various points on the platform. To examine smoke extraction and air supply capacity in the platform level, air velocities were checked on opening vents. Numerical analysis under normal ventilation mode without fire is conducted by using measured boundary conditions, and the numerical results are compared with the measured velocities on the platform.

The Smoke Propagating Distance in the Reduced-scale Model for a Subway Railroad Tunnel (축소 모형을 이용한 지하철터널에서의 연기전파거리 측정)

  • Kim, Myung-Bae;Choi, Byung-Il;Oh, Chang-Bo;Han, Yong-Shik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.4
    • /
    • pp.295-304
    • /
    • 2005
  • The smoke propagating distances are measured in case that a fire occurs within the subway railroad tunnel. The tunnel is 800m long and the dimension of the cross-section is. Three vertical shafts exist for smoke ventilation. The experiments are performed using the 1/50 reduced-scale model. The smoke propagating distances are measured by thermocouples and by visualization for the accuracy. In order to understand the effect of a fire size and ventilation capacity of the shafts on the smoke propagating distance, 9 test scenarios are chosen. Based on the results, the smoke propagating distance is shown to be important criteria for the ventilation design of the tunnel.

  • PDF

A Study on the Integrated Ventilation Control Algorithm for Road Tunnels (다중터널의 통합환기제어 알고리즘 연구)

  • Kim, Tae-Hyung;Hong, Dae-Hie;Chu, Baek-Suk;Kim, Dong-Nam;Keum, Jae-Sung;Kim, Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.405-409
    • /
    • 2008
  • Over 70% of the land is mountains in Korea, so that many roadways naturally includes tunnels. The air flow inside tunnel has complex characteristics, such that a new flow field is formed by following vehicles passing through the tunnel before previous flow field is stabilized. Due to these time delayed-transient characteristics, the ventilation facility requires the complex control algorithm that can handle adaptive and predictive controls. Also, it needs to be closely related to the disaster prevention system. The technology to integrate these system determines the success of TGMS. The pollutant levels exhausted from the vehicles passing through tunnel depend on vehicle years and passing velocity. They also depend on the slope and altitude of the tunnel. In order to solve this problem, an algorithm for estimating the compensating factors for calculating on design capacity of ventilation facilities was developed. Also, an integrated ventilation control algorithm with disaster prevention program to operate several tunnels was developed based on TGMS.

  • PDF

Pulmonary Function Following Open Heart Surgery -early and late postoperative changes- (개심술후 폐기능 -수술직후 및 장기간의 추이에 대하여-)

  • 이성행
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.364-374
    • /
    • 1980
  • Twenty-two patients were selected for evaluation of pre-and postoperative pulmonary function. These patients were performed open cardiac surgery with the extracorporeal circulation from March 1979 to July 1980 at the Department of Thoracic and Cardiovascular Surgery, Kyungbook National University Hospital. Patients were classified with ventricular septal defect 5 cases, atrial septal defect 5 cases, tetralogy of Fallot 5 cases, mitral stenosis 4 cases, rupture of aneurysm of sinus Valsalva 1 case, left atrial myxoma I case, and aortic insufficiency 1 case. The pulmonary function tests were performed and listed: [1] respiratory rate, tidal volume [TV], and minute volume[MV], [2] forced vital capacity [FVC] and forced expiratory volume[FEV 0.5 & FEV 1.0], [3] forced expiratory flow [FEF 200-1200 ml & FEF 25-75%]. [4] Maximal voluntary ventilation [MVV], [5] residual volume [RV] and functional residual capacity[FRC], measured by a helium dilution technique. Respiratory rate increased during the early postoperative days and tidal volume decreased significantly. These values returned to the preoperative levels after postoperative 5-6 days. Minute volume decreased slightly, but essentially unchanged. Preoperative mean values of the forced vital capacity, functional residual capacity and total lung capacity decreased [63.2%, 87.2% & 77.3% predicted, respectively], and early postoperatively these values decreased further [19.6%, 76.0% & 38.0% predicted], but later progressively increased to the preoperative levels. In residual volume, there was no decline in the preoperative mean values [100.9% predicted] and postoperatively the value rather increased [106.3-161.7% predicted]. Forced expiratory volume [FEV 0.5 & FEV 1.0] and forced expiratory flow [FEF 200-1200 ml & FEF 25-75%] also revealed significant declines in the early postoperative period. There was no significant difference in values of the spirometric pulmonary function tests, such as FEF 1.O and FEF 25-75% between successful weaning group [17 cases] extubated within 24 hrs post-operatively and unsuccessful weaning group [5 cases] extubated beyond 24 hrs. Static compliance and airway resistance measured for the two cases during assisted ventilation, however, any information was not obtained. Long term follow-up pulmonary function studies were carried out for 8 cases in 9 months post-operatively. All of the results returned to the pre-operative or to normal predicted levels except FVC, FEV 1.0, and FEF 25-75% those showed minimal declines compared to the pre-operative figures.

  • PDF

Effect of Rowing Ergometer Training on the Aerobic Capacity and Strength of Male High School Students (로잉 에르고미터 훈련이 남자고등학생의 유산소능력과 근력에 미치는 효과)

  • Kim, Dong-Hee;Yuk, Ji-Min;Park, Hyeok;Lim, Jae-Heon;Kim, Seok-Hwan
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.187-194
    • /
    • 2018
  • Purpose: This study aimed to assess the effect of rowing ergometer training on the aerobic capacity and strength of male high school students over a 12-week period. Methods: Fourteen high school students volunteered to participate in the study. The subjects were divided into two groups: seven subjects in the experimental group and seven in the control group. The subjects in the experimental group performed rowing ergometer training for 75 min per session at three days a week for 12 weeks. The exercise intensity set the maximum heart rate (HRmax) from 40% to 80%. Aerobic capacity was measured by ventilation, cardiac output, and oxygen intake per body weight. Strength was measured by grip strength and back strength before and after training. Results: A significantly increased ventilation (p=0.01), cardiac output (p=0.01), and oxygen intake per body weight (p=0.00) were found in the experimental group. A significantly increased grip strength in the right and left hands (p=0.00, 0.00) and back strength (p=0.04) were observed in the experimental group. Conclusion: Rowing ergometer training can be an effective combined exercise for aerobic capacity and strength of high school students.

Convergence Analysis of the betweenBone Mineral Density, Cardiorespiratory Functional Capacity and sports injury of youth Taekwondo Athletes (유소년 태권도 선수들의 골밀도 및 심폐기능과 스포츠 손상과의 융복합 연구)

  • Kim, June-Chul;Park, Ki-Jun
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.125-131
    • /
    • 2020
  • This study sought to reduce the risk of fractures in elite youth taekwondo athletes to find out the relationship between bone mineral density which are used as indicators of early diagnosis of osteoporosis and cardiorespiratory functional capacity which is an indicator of performance and sports injury the harmful to athletes. The Pearson product-moment correlation was performed to investigate the correlation between bone mineral density, cardiorespiratory functional capacity, and sports injury. The bone mineral density and cardiorespiratory functional capacity, sports injury were examined the relationship using the Simple Linear Regression. The bone mineral density were correlated with the ventilation (r=.388), and VO2max (r=.478). Bone mineral density was correlated with sports injury (r=-.292). When the bone mineral density increased by .002 and .006, the ventilation (p=.001) and VO2max (p=.006) increased by about 1. In addition, when the bone mineral density decline by .016, the sports injury increased by about 1. Improving athletes' bone mineral density can prevent sports injury, and it can be used as a sports injury prevention program in the future.

A Study on the development of a decision model on free flow and congested traffic conditions to determine the optimal ventilation capacity in highway tunnels (고속도로 터널의 적정 환기용량 계획을 위한 원활 및 지체조건 판별모델 개발에 대한 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.4
    • /
    • pp.375-395
    • /
    • 2012
  • According to the local highway tunnel ventilation guideline, ventilation capacity calculation should be performed at the speed ranging from 10 km/h to 80 km/h. This is so reasonable method considering uncongested and congested traffic conditions in urban tunnels. But recently due to low traffic volume and very low congestion frequency in rural highway tunnels, it seems to be an inadequate way to apply the guideline. Therefore the calculation should be performed separately for the free flow and congested traffic cases classified by the appropriate decision model. This paper aims at determining unnecessary running speed range for reasonable tunnel ventilation design, considering free flow and congested traffic conditions. Firstly, traffic volumes in highway tunnels were collected and if any, the causes of congestion were investigated. And with concept of 'margin speed'($u-u_m$), the decision model on traffic congestion was developed. Applicability of the decision model was also analyzed with case study. According to the results, when design speed is 100 km/h, with V/C less than 0.1, then the range of unnecessary speed in tunnel ventilation design is less than 40 km/h; for $V/C{\leqq}0.35$, $V/C{\leqq}0.6$ and $V/C{\leqq}0.75$, the unnecessary speed ranges are found to be ${\leqq}30$, ${\leqq}20$ and ${\leqq}10km/h$, respectively.

Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling - (겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 -)

  • Lee J. S.;Han C. S.;Ham T. M.;Yon K. S.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.