Effective and systematic sanitation management programs are necessary to prevent foodborne disease outbreaks in school foodservice operations. The purpose of this study was to identify the elements to improve in order to ensure the safety of school food service by evaluating sanitation management practices implemented under HACCP-based programs. The survey was designed to assess the level of hygiene practices of school food service by using an inspection checklist of food hygiene and safety. Fifty-four school foodservice establishments considered as poor sanitation practice groups from two year inspections by Seoul Metropolitan Office of Education were surveyed from September to December in 2005. Inspection checklists consisted of seven categories with 50 checkpoints; facilities and equipment management, personal hygiene, ingredient control, process control, environmental sanitation management, HACCP system and safety management. Surveyed schools scored $68.0{\pm}12.42$ points out of 100 on average. The average score (% of compliance) of each field was 10.7/20 (53.3%) for facilities and equipment management, 7.4/11 (67.2%) for personal hygiene, 7.4/11 (74.1%) for ingredient control, 22.4/32 (69.8%) for process control, 8.9/12 (73.8%) for environmental sanitation management, 4.2/7 (59.7%) for HACCP systems management, and 7.2/8 (89.7%) for safety management, respectively. The field to be improved first was the sanitation control of facilities and equipment. The elements to improve this category were unprofessional consultation for kitchen layout, improper compartment of the kitchen area, lacks of pest control, inadequate water supply, poor ventilation system, and insufficient hand-washing facilities. To elevate the overall performance level of sanitation management, prerequisite programs prior to HACCP plan implementation should be stressed on the school officials, specifically principals, for the integration of the system.
Three methods for VOCs emissions control in indoor air are reduction at the source, ventilation between indoor and outdoor, and removal. The best alternative should be to replace highly emitting sources with sources having low emissions, but the pertinent information on VOCs is not always available from manufactures. Other ways of improving indoor air quality are needed. It is to increase the outside fresh-air flow to dilute the pollutants, but this method would generally provide only a dilution effect without destruction in residence. An ideal alternative to existing technologies would be a chemical oxidation process able to treat large volumes of slightly contaminated air at normal temperature without additional oxidant such as ozone generator and ion generator. Photocatalytic oxidation(PCO) represents such a process. It is characterized by a surface reaction assisted by light radiation inducing the formation of superoxide, hydroperoxide anions, or hydroxyl radicals, which are powerful oxidants. In comparison with other VOCs removal methods, PCO offers several advantages. The purpose of this study was to explore the possibilities for photocatalytic purification of slightly contaminated indoor air by using visible light such as flurescent visible light(FVL). In this study, a PCO of relatively concentrated benzene using common FVL lamps was investigated as batch type and total volatile organic compounds(TVOCs) using a common FVL lamp and penetrated sun light over window. The results of this study shown the possibility of TiO$_2$ photocatalyst application in the area of indoor air quality control.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.29
no.2
/
pp.259-269
/
2019
Objective: This study was conducted to prepare fundamental data and assess the relationship between level of exposure to airborne respirable dust, chest radiation findings, and the results of pulmonary function tests among workers in a cloth manufacturing factory. Methods: The number of total subjects was 144 (124 female and 20 male) workers in a cloth manufacturing factory in the city of Busan. This study measured the concentration of airborne respirable dust by gravimetric analysis and performed pulmonary function testing, and got chest radiation findings from December 1, 2016 to March 31, 2017. Collected data was analyzed using the IBM SPSS statistical package program (ver. 24.0). Results: The mean concentration of respirable dust was the highest in the cutting process. The effecting factors on $FEV_1/FVC$ were age, sex, and working process. The effecting factors on chest radiation findings were doing no exercise and concentration of respirable dust. Conclusions: Based on the above results, the authors consider there to be a need to secure sufficient working space and improve the engineering systems, for example the overall or local ventilation, in order to minimize the exposure to respirable dust. Health education and health promotion activities should also be improved in order to maintain optimal health status. The authors expect further studies to be performed on pulmonary function testing, chest radiation findings, and symptoms related to pulmonary function, including continuous observation, among workers in a cloth manufacturing factory.
This study identified the characteristics of fashion rental service users as well as analyzed their purchase decision-making processes. A qualitative investigation was conducted through in-depth interviews with 13 women in their 20s-30s who have experienced renting fashion items due to a high interest in fashion. The results of the study are summarized as follows. The need recognition stage analyzed ventilation by mass media, SNS impact, curiosity, saving shopping time and money, awareness of situational necessity, and creation of various styles. The information search stage analyzed how users obtained information from 2 different sources of nonmarketer-dominated sources and marketer-dominated sources. The pre-purchase stage analyzed the evaluation of alternatives in which study participants used 2 evaluation criteria for fashion rental services and fashion rental items. The purchase stage analyzed how participants wait and select desired items (when receiving the notification of rentable items) or select alternative products. The consumption stage examined the usage frequency and usage method. The study divided the post-consumption evaluation stage into 2 categories for evaluation: personal feelings and service. The post-consumption behavior stage analyzed how participants displayed WOM, eWOM and purchase rental product behavior. Clothing shopping orientation of study participants is displayed in 5 dimensions of brand-seeking propensity, individuality-seeking propensity, economic efficiency-seeking propensity, rationality-seeking propensity, and pleasure-seeking propensity. This study identified three main characteristics in the study participants: interest in the fashion, favorable attitude toward used fashion items, consciousness of others.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.33
no.3
/
pp.291-297
/
2023
Objectives: An epidemiological investigation was requested for a worker who developed COPD and IPF after long-term molding and firing at a domestic tile manufacturing site. We would like to share the results of the exposure assessment and the estimation of past work. Methods: The content of crystalline silica in four raw materials was analyzed, and the respirable fraction of crystalline silica and dust generated in the air from molding and firing workers and other processes were measured. The measurement and analysis method referred to the NIOSH method. Results: The crystalline silica content of the raw material was 24~47%. The concentration of crystalline silica in the molding and firing process workers and the surrounding area was at the level of the exposure standards set by the Ministry of Employment and Labor and ACGIH, and the respirable and total dust exposure levels were generally low. The crystalline silica concentration of the area samples measured to estimate past work was about twice as high as the exposure standard of the Ministry of Employment and Labor (0.05 mg/m3), and the exposure levels of respirable dust were also quite high at 0.903 and 1.332 mg/m3. Conclusions: It was confirmed that tile molding and firing workers are currently exposed to a fairly high level of crystalline silica, and a high level is also confirmed in area samples to estimate past work. In the past, it is judged that the level of exposure would have been much higher due to differences in production volume, working method, presence/absence of local ventilation facilities, and process layout. When working in such a working environment for a long time, respiratory diseases such as lung cancer, COPD, and IPF can occur.
The Journal of Sustainable Design and Educational Environment Research
/
v.6
no.2
/
pp.66-90
/
2007
The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.
Park, Ji-Young;Lee, Jung-A;Yun, Sung-Hun;Park, Min-Kyou;Kim, Chang-Hyun;Park, Je-Uk
Maxillofacial Plastic and Reconstructive Surgery
/
v.29
no.1
/
pp.79-84
/
2007
Acute respiratory distress syndrome(ARDS) is severe acute hypoxic respiratory failure state with dynamic impairment in oxygen and carbon dioxide transfer with the need for high levels of supplementary oxygen and a high minute ventilation. This syndrome is caused by pulmonary edema due to increased permeability of the alveolar capillary barrier by various factors. ARDS is an uncommon, but a potentially life-threatening complication. Therefore, immediate diagnosis and appropriate therapy must be performed. The present case is post-extubation ARDS immediately occurred in an orthognathic surgery patient who are healthy 19-year-old man. He rapidly recovered from ARDS without complication by early diagnosis and proper treatment. This case report was aimed to describe the process of the development, possible causes and the management of ARDS occurred in an orthognathic surgery patient
In this paper, we propose the real time indoor air quality monitoring and controlling platform on cloud using IoT sensor data such as PM10, PM2.5, CO2, VOCs, temperature, and humidity which has direct or indirect impact to indoor air quality. The system is connected to air ventilator to manage and optimize the indoor air quality. The proposed system has three main parts; First, IoT data collection service to measure, and collect indoor air quality in real time from IoT sensor network, Second, Big data processing pipeline to process and store the collected data on cloud platform and Finally, Big data analysis and visualization service to give real time insight of indoor air quality on mobile and web application. For the implication of the proposed system, IoT sensor kits are installed on three different public day care center where the indoor pollution can cause serious impact to the health and education of growing kids. Analyzed results are visualized on mobile and web application. The impact of ventilation system to indoor air quality is tested statistically and the result shows the proper optimization of indoor air quality.
Dae Joon Lee;Sang Ryung Kim;Sang Gil Kim;Chung Sang Kang;Joon Won Lee
Journal of the Korean Institute of Gas
/
v.27
no.2
/
pp.79-85
/
2023
Recently, in the semiconductor process, large companies are seeking process changes from memory semiconductors to the foundry due to the increase in demand due to the 4th industry. industry is expanding. The characteristics of special gases and precursors, which are raw materials used to produce these semiconductor chips, are toxic, pyrophoric, inflammable, and corrosive. These semiconductor raw materials are operated in a closed system and do not leak to the outside during normal times, but when leaked, they spread to the inside of the gas box, and when proper ventilation is not provided inside the gas box, they spread to the outside, causing fires, explosions, or toxic substances. It can lead to major accidents such as leakage. Recently, there have been cases of accidents in which hazardous materials leaked from the closed system of the semi conductor process and spread to the inside and outside of the gas box. . In this study, we propose preventive measures based on the case of an accident in which raw material leaked from the VCR fitting, which is the connection part of the semiconductor raw material transfer pipe, and spread to the outside of the gas box.
Journal of Korean Tunnelling and Underground Space Association
/
v.24
no.6
/
pp.637-658
/
2022
TBM tunnel is simple with the iterative process of excavating the ground, building a segment ring-build, and backfilling. Drill & Blast, a conventional tunnel construction method, is more complicated than the TBM tunnel and has some restrictions because it repeats the inspection, drilling, charging, blasting, ventilation, muck treatment, and installation of support materials. However, the preparation work for excavation requires time and cost based on a very detailed plan compared to Drill & Blasting, which reinforces the ground and forms a tunnel after the formation of tunnel portal. This is because the TBM equipment for excavating the target ground determines the success or failure of the construction. If the TBM, an expensive order-made equipment, is incorrectly configured at the assembly stage, it becomes difficult to excavate from the initial stage as well as the main excavation stage. When the assembled shield TBM equipment is dismantled again, and a situation of re-assembly occurs, it is difficult throughout the construction period due to economic loss as well as time. Therefore, in this study, the layout and plan of the site and the assembly process for each major part of the TBM equipment were reviewed for the assembly of slurry shield TBM to construct the largest diameter road tunnel in domestic passing through the Han River and minimized interference with other processes and the efficiency of cutter head assembly and transport were analyzed and improved to suit the site conditions.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.