• Title/Summary/Keyword: Ventilation Fan

Search Result 279, Processing Time 0.02 seconds

Thermal Environment Analysis of a Room in Accordance with Ventilation Condition with Multi-Heat Sources (다수의 열원을 가지는 공간에서의 환기 조건에 따른 열환경 해석)

  • Kim, Jae-Jung;Son, Young-Gap;Chang, Seog-Weon;Ryu, Dong-Su
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.199-204
    • /
    • 2000
  • This paper reports a thermal environmental analysis of a room in accommodated with multi-heat sources according to ventilation condition. Two case modification have been investigated to obtain the lower temperature distribution in the room. The temperature distribution of the original room were found about $25{\sim}35^{\circ}C$. As a result, the use of, three ventilating fans and two electric fans are useful for room ventilation respectively, and using two electric fan is more recommendable in side of economical efficiency.

  • PDF

Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System (돈사용 환기팬을 위한 돈사 내 온도 분포 특성)

  • Kim, Hyeon-Tae;Kim, Woong
    • Journal of Animal Environmental Science
    • /
    • v.20 no.4
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

CFD-based Design and Analysis of the Ventilation of an Electric Generator Model, Validated with Experiments

  • Jamshidi, Hamed;Nilsson, Hakan;Chernoray, Valery
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.113-123
    • /
    • 2015
  • The efficiency of the ventilation system is a key point for durable and reliable electric generators. The design of such system requires a detailed understanding of the air flow in the generator. Computational fluid dynamics (CFD) has the potential to resolve the lack of information in this field. The present work analyses the air flow inside a generator model. The model is designed using a CFD-based approach, and manufactured by taking into consideration the experimental and numerical requirements and limitations. The emphasis is on the possibility to accurately predict and experimentally measure the flow distribution inside the stator channels. A major part of the work is focused on the design of an intake and a fan that gives an evenly distributed flow with a high flow rate. The intake also serves as an accurate flowmeter. Experimental results are presented, of the total volume flow rate, the total pressure and velocity distributions. Steady-state CFD simulations are performed using the FOAM-extend CFD toolbox. The simulations are based on the multiple rotating reference frames method. The results from the frozen rotor and mixing plane rotor-stator coupling approaches are compared. It is shown that the fan design provides a sufficient flow rate for the stator channels, which is not the case without the fan or with a previous fan design. The detailed experimental and numerical results show an excellent agreement, proving that the results reliable.

A Valuation and Improvement of Industrial Ventilation System of Printing Process in Synthetic Leather Factory using Dimethylformamide (DMF를 사용하는 합성피혁 공장 인쇄공정의 산업환기시스템 평가 및 개선)

  • Lee, Sun Woo;Kim, Tae Hyeung;Kim, Jung Man;Kim, Jong Cheul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.113-126
    • /
    • 2009
  • In the recent years, health effect of dimethylformamide(DMF) has been one of critical industrial hygiene issues. There might be many factors to increase the exposure level of DMF. Among those factors, industrial ventilation would be one of the main factors. In this study, industrial ventilation systems of printing processes in synthetic leather factories were thoroughly surveyed and the improved ventilation systems were proposed. 7 synthetic leather factories were selected for this study. After the ventilation systems were visually inspected, each component of the system was tested by using the appropriate instruments. Hood face velocities, fan exhaust flow rates, fan static pressures, fan rotation rates, etc were measured. In addition, flow visualization techniques were used to observe flow patten around hoods and inside the factory buildings. After gathering all qualitative and quantitative information, the test results were analysed to see if any improvement might be necessary. For the system to be improved, the re-design plans were made by using computational fluid dynamics softwares. The softwares used in this study were AIRPAK and STAR-CD. The effectiveness of the several improvement options were tested, then the best cost effective option was selected. Finally, the standard ventilation systems were proposed to minimize the exposure levels of DMF.

Venturi Effects Induced by the Local Ventilation Fan in Large-Opening Room-and-Pillar Mining Sites (대단면 갱내 국부 선풍기의 벤츄리(Venturi) 효과 연구)

  • Lee, Chang Woo;Nguyen, Van Duc
    • Tunnel and Underground Space
    • /
    • v.24 no.6
    • /
    • pp.464-472
    • /
    • 2014
  • In large-opening room-and-pillar mining sites, particularly without the devices for the ventilation control, the airflow pattern created by the local fan operation is too complicated to quantify and also shows low ventilation efficiency. This study aims at performing a series of CFD analysis for the so-called venturi effects of the local fans; the effects of increasing airflow rate along the axis downstream of fan resulting from increased kinetic energy and subsequently decreased static pressure in the downstream. Effects of the fan type and installation height are compared. 1 vane-axial fan and 2 propeller fans are analyzed for their venturi effects, while the vane-axial fan was installed at the height of 1.0, 1.5 and 2.0m for comparison. The results can be applied to improve the economy and efficiency of local fans for securing better air quality and work environment management.

A Study on the Mechanical Ventilation System of Bathroom in Apartment House (공동주택 화장실의 기계 환기시스템에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.12 no.3
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

A STUDY ON AERODYNAMIC CHARACTERISTICS DEPENDING ON SHAPE OF AN INTERNAL MOTOR IN A SIROCCO FAN FOR RESIDENTIAL VENTILATION (주거환기용 시로코홴의 내부모터 형상에 따른 공력특성 연구)

  • Cha, K.H.;Kim, J.H.;Kim, K.Y.
    • Journal of computational fluids engineering
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2011
  • Aerodynamic characteristics depending on the shape of an internal motor in a small-size sirocco fan for residential ventilation have been investigated. For the aerodynamic analyses of the sirocco fan, three-dimensional Reynolds-averaged Navier-Stokes equations are solved with the shear stress transport model for turbulence closure. The flow analyses are performed on hexahedral grids using a finite-volume solver. The validation of the numerical results at steady-state is performed by comparing with experimental data for the pressure and efficiency. In order to investigate the aerodynamic characteristics depending on shape of an internal motor in a sirocco fan, the reference shape is analyzed compared to the case without internal motor. Additionally, two shape parameters, height and width of the internal motor in a sirocco fan, are tested to investigate their effects on the aerodynamic characteristics. The results show that the shape of the internal motor in a sirocco fan is an important factor to improve the aerodynamic performances.

A STUDY ON AERODYNAMIC CHARACTERISTICS DEPENDING ON SHAPE OF AN INTERNAL MOTOR IN A SIROCCO FAN FOR RESIDENTIAL VENTILATION (주거환기용 시로코홴의 내부모터 형상에 따른 공력특성 연구)

  • Cha, K.H.;Kim, J.H.;Kim, K.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.321-326
    • /
    • 2011
  • Aerodynamic characteristics depending on the shape of an internal motor in a small-size sirocco fan for residential ventilation have been investigated For the aerodynamic analyses of the sirocco fan, three-dimensional Reynolds-averaged Navier-Stokes equations are solved with the shear stress transport model for turbulence closure. The flaw analyses are performed on hexahedral grids using a finite-volume solver. The validation of the numerical results at steady-state is performed by comparing with experimental data for the pressure and efficiency. In order to investigate the aerodynamic characteristics depending on shape of an internal motor in a sirocco fan, the reference shape is analyzed compared to the case without internal motor. Additionally, two shape parameters, height and width of the internal motor in a sirocco fan, are tested to investigate their effects on the aerodynamic characteristics. The results show that the shape of the internal motor in a sirocco fan is an important factor to improve the aerodynamic performances.

  • PDF

A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types (초청정 클린룸 공조방식에 따른 기류특성에 관한 수치해석)

  • 노광철;이승철;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.751-761
    • /
    • 2003
  • We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.

A Study on the Airflow Distribution in the Diagonal Ventilation Circuit for the Design of a High Level Radioactive Waste Repository (고준위 방사성 폐기물 처분장 설계를 위한 Diagonal 환기 회로 내 공기량 분배에 관한 연구)

  • Hwang, In-Phil;Choi, Heui-Joo;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.173-180
    • /
    • 2012
  • In this study, diagonal ventilation circuits that are advantageous in air flow direction control were studied. Based on the results of the study, it could be seen that air volumes in diagonal ventilation circuits could also be calculated using numerical formulas or programs if the air volumes and air flow directions to be infused into diagonal branches are determined in advance as with other serial/parallel circuits. To apply the results, design plans for high level radioactive waste repositories applied with diagonal ventilation circuits and parallel ventilation circuits. To compared the each design plans and obtain expected operation results, ventilation network simulations were conducted through the Ventsim program which is a ventilation networking program. Based on the results, in the case of diagonal repositories that was expected to cause great increases in resistance, fan pressure was 1570 pa, total flux was 84 $m^3/s$, fan efficiency was 76.4%, fan power consumption was 181.2 kW and annual fan operating costs were 178,710,838 and thus maximum around 8% differences were shown in pressure and flux values and a difference of around 1.5% was shown in terms of operating costs.