A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types  

노광철 (서울시립대학교 대학원 기계공학과)
이승철 (동해대학교 자동차공학과)
오명도 (서울시립대학교 기계정보공학과)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.15, no.9, 2003 , pp. 751-761 More about this Journal
Abstract
We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.
Keywords
Cleanroom; Axial fan type system; Fan filter unit system; Deflection angle; Nonuniformity; Ventilation effectiveness;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Cleanroom and contamination control /
[ Cho,S.J ] / Society of Air-Conditioning and Refrigeration-Lecture on the Refrigeration
2 Study on the characteristic of the air flow and particle diffusion in the cleanroom /
[ Yang,H.C.;Oh,M.D.;Lee,C.S. ] / Preceedings of the SAREK 1987 Winter Annual Conference
3 High isolation minienvironment for process involving toxic substances /
[ Jancoski,C.A.;Sinclair,J.D. ] / Proceedings Institute of Environmental Sciences
4 /
[ Computational Dynamics Ltd. ] / STAR-CD Version 3.15 User Manual
5 Comparison of different K-ε models for indoor airflow computations /
[ Chen,Q. ] / Numerical Heat Transfer
6 Filter pleating designs /
[ Pui,Y.H. ] / International Symposium on Air Cleaning Technology
7 A trend of GIGA level cleanroom technology /
[ Oh,M.D. ] / International Symposium on Clean Technology and Management for Indoor Air
8 Airflow characteristic experiments for the upper plenum design of clean room /
[ Oh,M.D.;Bae,G.N.;Kim,S.C.;Lee,S.C. ] / Korean Journal of Air-Conditioning and Refrigeration
9 Cleanrooms and associated controlled environments-Part 1:Classification of air cleanliness /
[] / ISO 14644-1
10 Ventilation efficiency as a guide to design /
[ Sandberg,M. ] / ASHRAE trans.
11 Design and evaluation of a minienvironment for semiconductor manufacture process /
[ Hu,S.C.;Chuah,Y.K.;Yen,M.C. ] / Building and Environment   ScienceOn
12 A experimental study on the airflow characteristics for clean tunnel type cleanroom design /
[ Bae,G.N.;Lim,H.K.;Oh,M.D. ] / Korean Jounal of Air-Conditioning and Refrigeration
13 Deterministic simulation and assessment of air-recirculation performance of unidirectional-flow cleanrooms that incorporate age of air concept /
[ Hu,S.C.;Chuah,Y.K ] / Building and Environment   ScienceOn
14 Study on the laminar and turbulent flow sharing for the particle control in the cleanroom /
[ Oh,M.D.;Lee,C.S. ] / Preceedings of the SAREK1987 Summer Annual Conference
15 Study on the thermal and fluid characteristic in the cleanroom /
[ Chang,Y.C. ] / Society of Air-Conditioning and Refrigeration Lecture on the Industrial equipments
16 Next generation cleanroom technology and air quality control /
[ Kim,K.Y. ] / Magazine of the Society of Air-Conditioning and Refrigeration
17 /
[ Patankar,S.V. ] / Numerical Heat Transfer and Fluid Flow
18 Effects of the floor panel on flows in a vertical laminar flow type clean room /
[ Kang,S.H.;Jeon,W.P.;Oh,M.D. ] / Korean Journal of Air-Conditioning and Refrigeration