• 제목/요약/키워드: Ventilation Axial-flow Fan

검색결과 11건 처리시간 0.024초

환기용 축류송풍기의 유동해석 및 모터 위치에 따른 성능 특성 연구 (Flow Analysis and Performance Evaluation of a Ventilation Axial-Flow Fan Depending on the Position of Motor)

  • 김재우;김진혁;김광용
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.25-30
    • /
    • 2010
  • Flow analysis and performa nce evaluation have been performed for a ventilation axial-flow fan with different positions of the motor. Two different positions of motor have been tested; one is in front of the impeller and the other is behind the impeller. Flow analyses are performed by solving three-dimensional Reynolds-averaged Navier-Stokes equations through a finite-volume solver. Preliminary numerical calculations are carried out to test the performances of different turbulence models, i.e., SST model, k-$\omega$ model, and k-$\varepsilon$ model with and without using empirical wall function in the flow analysis. The validation of numerical analyses has been performed in comparison with the experimental data. The numerical results for the performance characteristics of the ventilation axial-flow fan with two different positions of the motor have been presented.

대단면 석회석 광산 갱도 내 국부선풍기 승압력 및 통기효과 비교 연구 (A Comparative Study on the Auxiliary Fan Pressure and the Ventilation Efficiency in Large-opening Limestone Mine Airways)

  • 박동준;강현호;이창우
    • 터널과지하공간
    • /
    • 제27권1호
    • /
    • pp.1-11
    • /
    • 2017
  • 국내 지하 석회석 광산은 대부분 대단면 갱도로 개발되고 있으며 갱내통기는 주요 선풍기에 의한 통기방식보다는 자연통기 및 국부통기에 의존하고 있다. 국부통기는 국부선풍기와 풍관을 이용한 급배기 통기방식을 적용하고 있으나 대단면 갱도 특성과 갱내 굴진 운반장비의 디젤화에 따라 소요통기량이 대폭 증대하여 통기의 효율 및 경제성 확보가 주요과제로 대두되고 있다. 본 연구에서는 대단면 갱내 작업장 국부통기를 위한 선풍기 용량 최적화를 위하여 축류식 및 프로펠러 선풍기를 개발하여 갱내 승압력 및 통기효과를 비교 분석함을 목적으로 한다.

ANSI/AMCA 210 기준에 의한 대형 축류 송풍기의 성능시험 및 측정 불확도 평가 (An Estimation of Performance Test and Uncertainty of Measurement for a Large Axial-flow Fan Based on ANSI/AMCA 210 Standard)

  • 고희환;정철영;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.24-29
    • /
    • 2014
  • In general, a large-capacity axial flow fan is used for industrial processes or ventilation in a social overhead capital infrastructure. The main characteristics of the large axial-flow fan need a lot of electrical power consumption and operate 24 hours a day, 365 days a year. Since the large axial flow fan consumes several hundreds to thousands kW per hour, both manufacturer and consumer are struggling to select high efficiency products for saving energy and reducing operation cost. Therefore, the performance testing should be accurately conducted in experimental equipments. The performance estimation and uncertainty of measurement of the axial-flow fan gathered from the result from nozzle shaped testing equipments certified with ANSI/AMCA standard and duct shaped testing equipment under the same experimental condition. The experimental results from both facilities have maximum 17% differences in performance evaluation and uncertainty of measurement. As considering that the differences, it is doubt about the reliability of testing result. The test was repeated with the specific term during 12 months because it is important to fully reflect the real conditions and to decide the repeatability of data. The evaluation of duct type testing facilities was failed to get an uncertainty measure. Testing results were previously published. As a series of previous paper, axial fan (∅1690 mm) and duct type testing facilities were fabricated. The purpose of fabricating testing equipment was testing an uncertainty measurement under the controlled environments.

가중평균대리모델을 이용한 환기용 축류송풍기의 고효율 최적설계 (High-Efficiency Design of a Ventilation Axial-Flow Fan by Using Weighted Average Surrogate Models)

  • 김재우;김진혁;이찬;김광용
    • 대한기계학회논문집B
    • /
    • 제35권8호
    • /
    • pp.763-771
    • /
    • 2011
  • 본 연구에서는 환기용 축류송풍기에 대하여 효율을 목적함수로 하는 수치최적설계를 수행하였다. 유동해석은 삼차원 Reynolds-averaged Navier-Stokes(RANS) 방정식을 통하여 이뤄졌으며, 난류모델로는 Shear Stress Transport 모델을 사용하였다. 최적설계를 위한 설계변수로는 허브비, 날개의 중간 및 팁 스팬에서의 엇갈림각을 사용하였다. 실험계획법으로 라틴하이퍼큐브 샘플링 방법을 사용하여 설계영역 내에서 25개의 실험점을 추출하였다. 최적설계기법인 가중평균대리모델과 삼차원 RANS 해석을 결합하여 수치최적설계를 수행하였으며, 가중평균대리모델로는 WTA1, WTA2 및 WTA3 모델을 사용하였다. 수치 최적설계에 의해 얻어진 최적형상들의 성능을 기준형상과 비교하였으며, 성능이 가장 좋은 모델에 대하여 기준형상과의 내부유동장 비교 및 분석을 통해 성능이 향상된 원인을 규명하였다.

초청정 클린룸 공조방식에 따른 기류특성에 관한 수치해석 (A Numerical Analysis on the Airflow Characteristics in Super Cleanrooms with Different Design Types)

  • 노광철;이승철;오명도
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.751-761
    • /
    • 2003
  • We performed the numerical analysis on the airflow characteristics in the two type of cleanroom systems, which are the axial fan type (AFT) and the fan filter unit (FFU). A computational fluid dynamic model was applied to investigate and compare the nonuniformity, the deflection angle and the air ventilation effectiveness of the two designs of cleanrooms when dampers are adjusted and not adjusted. And the flow-resistance models of the various components were used in this simulation. We know that the airflow characteristics of the cleanrooms are largely affected by damper adjusting And we also find out that the FFU system is superior to the AFT system through the comparison of the cleanroom performance indices.

A New Blade Profile for Bidirectional Flow Properly Applicable to a Two-stage Jet Fan

  • Nishi, Michihiro;Liu, Shuhong;Yoshida, Kouichi;Okamoto, Minoru;Nakayama, Hiroyasu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.449-455
    • /
    • 2009
  • A reversible axial flow fan called jet fan has been widely used for longitudinal ventilation in road tunnels to secure a safe and comfortable environment cost-effectively. As shifting the flow direction is usually made by only switching the rotational direction of an electric motor due to heavy duty, rotor blades having identical aerodynamic performance for bidirectional flow should be necessary. However, such aerodynamically desirable blades haven't been developed sufficiently, since most of the related studies have been done from the viewpoint of unidirectional flow. In the present paper, we demonstrate a method to profile the blade section suitable for bidirectional flow, which is validated by studying the aerodynamic performances of rotor blades of a two-stage jet fan experimentally and numerically.

에어컨 실외기 풍량증가를 통한 성능 향상 및 상대적 원가절감 (Improved Performance Through Air Conditioner Outdoor Fan Airflow Increase and Relative Cost Reduction)

  • 김재열;최승현;김성현;기석호;윤성운
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.570-574
    • /
    • 2012
  • Spread of household air conditioning system is continued to be increased. Axial fan in the external unit of air conditioning system is for ventilation and air supplying unit, and the related products have been widely adopted as household electronics, automobile engine, big sized blower in factory, tunnel, and subway. In this study, commercial 3-winged propeller fan is modified to shape and modified to 2-winged fan for the airflow increase and cost reduction. Using 3D modelling, the fan shape is modified, and analysis flow is adopted to provide the way to airflow increase and reduce cost while maintaining the same wind capacity.

직교류 홴의 유동 해석: 깃 형상 변화가 성능에 미치는 영향 (A Numerical Study on Flow through a Cross Flow Fan: Effect of Blade Shapes on Fan Performance)

  • 허남건;김욱;강신형
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.96-102
    • /
    • 1999
  • Cross flow fans are used in various applications, especially in industrial ventilation applications and in room air conditioners, due to their superior performance characteristics. Unlike radial and/or axial fans, the design of cross flow fans have been mostly based on earlier experiences and experiments. In the present study, numerical computations of flow fields through a cross flow fan used in room air conditioner are performed to investigate the detailed flow fields and to study the effect of the blade shape on performance curves to aid better design of the fan. Despite some discrepancies between the two results, it is seen from the present study that the computational results agree quite well with the qualitative experimental results. It is also shown from the present study that by having a different shape of blade, it is possible to achieve about $15\%$ increase in flow rates. The stimulating results of the present study can be used in the design of high performance cross flow fans with the use of optimal design algorithm and experimental verifications.

  • PDF

돈사용 환기팬을 위한 돈사 내 온도 분포 특성 (Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System)

  • 김현태;김웅
    • 한국축산시설환경학회지
    • /
    • 제20권4호
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

Vortex Features in a Half-ducted Axial Fan with Large Bellmouth (Effect of Tip Clearance)

  • Shiomi, Norimasa;Kinoue, Yoichi;Setoguchi, Toshiaki;Kaneko, Kenji
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권3호
    • /
    • pp.307-316
    • /
    • 2011
  • In order to clarify the features of tip leakage vortex near blade tip region in a half-ducted axial fan with large bellmouth, the experimental investigation was carried out using a 2-dimensional LDV system. Three sizes of tip clearance (TC) were tested: those sizes were 1mm (0.55% of blade chord length at blade tip), 2mm (1.11% of blade chord length at blade tip) and 4mm (2.22% of blade chord length at blade tip), and those were shown as TC=1mm, TC=2mm and TC=4mm, respectively. Fan characteristic tests and the velocity field measurements were done for each TC. Pressure - flow-rate characteristics and two-dimensional velocity vector maps were shown. The vortex trace and the vortex intensity distribution were also illustrated. As a result, a large difference on the pressure - flow-rate characteristics did not exist for three tip clearance sizes. In case of TC=4mm, the tip leakage vortex was outflow to downstream of rotor was not confirmed at the small and reference flow-rate conditions. Only at the large flow-rate condition, its outflow to downstream of rotor existed. In case of TC=2mm, overall vortex behaviors were almost the same ones in case of TC=4mm. However, the vortex trace inclined toward more tangential direction. In case of TC=1mm, the clear vortex was not observed for all flow-rate conditions.