• Title/Summary/Keyword: Ventilating

Search Result 226, Processing Time 0.028 seconds

A Study on Improvement of Controller Performance using Intelligent Control Method

  • Yoo, Seung-Sun;Kim, Moon-Seong;In, Chi-Ho;Kwak, Hoon-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.2031-2034
    • /
    • 2002
  • In this paper, by comparing the performance of HVAC(Heating Ventilating and Air Conditioning) by the typical PI(Proportional Integral) control and the HVAC by the new neural network control, it will show the applicability of neural network control algorithm to HVAC of buildings. These show that neural network system that can respond to changes in temperature and system can replace PI control that has been conventionally used in buildings.

  • PDF

The Comparison of the Clinical Results Between Vinyl House Workers and Land Farmers (하우스재배 종사자와 노지재배 종사자의 임상검사 비교)

  • Kim, Byung-Sung
    • Journal of agricultural medicine and community health
    • /
    • v.19 no.1
    • /
    • pp.25-29
    • /
    • 1994
  • In order to find out the effects of vinyl house body, the author compared the physical and laboratory examinations between 96 cases of vinyl house farmers and 96 cases of land farmers who lived in 3 Gun's in Kyoungnam Province from July, 1st through September, 30, 1993. The examination included blood pressure, CBC, urinalysis, and blood chemistry. Systolic blood pressure and alkaline phosphates levels were lower in vinyl house farmers than in land farmers. But white blood cell counts were higher in vinyl house farmers and the other results were not different between two groups. It suggests that the environment of vinyl house - small, poorly ventilating, hot and humid environment - affected human body, then those facts should be considered during construction of vinyl houses.

  • PDF

The Analysis of Ventilation of Road Tunnel in Fire (도로터널 화재시의 환기분석)

  • Kom, Sung-Joon;Ryu, Jin-Woong
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.9-13
    • /
    • 2003
  • Numerical experiments are done by a commercial code, PHOENICS to evaluate the backlayer phenomenon of smoke in case of the road tunnel fire. The independent and dependent variables are ventilation air velocity and the length of backlayer of smoke respectively. Hybrid scheme and ${\kappa}-{\varepsilon}$ turbulence model are adopted in the simulation process and mass residual is used as a convergence criterion. The experimental results say that the length of backlayer is reduced with the increase of ventilating air velocity and that there is a critical air velocity which prevents from the onset of backlayering phenomena. One finds that there is a fresh air region near the bottom of tunnel which could make the passenger escape safely from the polluted region by smoke. These phenomena come from the vertical stratification of the smoke air mixture in the tunnel.

  • PDF

Design of Optimized Multi-Fuzzy Controller by Means of Particle Swarm Optimization Algorithm for HVAC System (HVAC 시스템에 대한 PSO 알고리즘을 이용한 최적화된 Multi-Fuzzy 제어기 설계)

  • Jung, Seung-Hyun;Choi, Jeoung-Nae;Oh, Sung-Kwan;Choi, Han-Jong;Ryu, Byoung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.277-278
    • /
    • 2007
  • 본 논문은 HVAC(heating, ventilating, and air conditioning) 시스템에 대해 Particle Swarm Optimization(PSO) 알고리즘을 이용하여 최적화된 Multi-Fuzzy 제어기 설계를 제안한다. HVAC 시스템의 효율과 안정도에 결정적인 영향을 미치는 과열도와 저압(증발기의 압력)을 제어하기 위해, 3대의 Expansion Valve 와 1대의 Compressor 에서 동시에 제어하는 Multi-Fuzzy 제어기를 설계한다. 그리고 최적화 알고리즘 중 하나인 사회적인 행동양식을 기반한 PSO 알고리즘을 이용하여 설계된 Multi-Fuzzy 제어기를 최적화한다. 시뮬레이션의 결과 비교를 통해, 대표적인 최적화 알고리즘인 유전자 알고리즘을 사용한 최적화된 제어기와 제안한 PSO 알고리즘을 이용한 최적화된 제어기의 성능을 평가한다.

  • PDF

A Diagnostic Technique for the Air Flow Characteristics in Refrigerators using PIV (PIV에 의한 냉장고 기류특성 평가방법)

  • Kim, Seok-Ro;Doh, Deog-Hee;Lee, Jae-Keun;Kim, Kyung-Chun
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.576-584
    • /
    • 2007
  • A PIV(Particle Imaging Velocimetry) diagnostic technique for the evaluation of the flow characteristics in refrigerator is introduced. Smoke particles of which density is small enough to follow up the air flow are used for visualization of the air flows in the refrigerators. A rectangular room model is tested for the verifications of the dignostic technique. By evaluating the turbulent intensity and the deviation value of the turbulent intensity distribution that were obtained from PIV results, an optimal ventilating condition is suggested. The constructed technique is used for the diagnostics on the flow of an actual refrigerator. It has experimentally proved that the present technique is able to evaluate the ventilation conditions of refrigerators.

  • PDF

Numerical Analysis on the HVAC Characteristics of Double-deck Train (2층 객차의 HVAC특성 전산해석)

  • Nam Seong-Won;Kim Hyeong-Jin
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.358-362
    • /
    • 2003
  • Numerical simulation is conducted to clarify the heat transfer and fluid flow characteristics of HVAC(Heating, Ventilating and Air-Conditioning} for double-deck train. The HVAC system is installed under the roof of carbody. In the lay-out of HVAC system, air duct must be installed to supply air to 1st and 2nd floor respectively. The standard k-epsilon turbulent models and SIMPLEC algorithm based on finite volume method are used to solve the physical HVAC model. To assure convergence, QUICK scheme for momentum equation and the first order upwind scheme for turbulent equations are used. From the results of simulation, the temperature and velocity magnitude are also distributed uniformly in the interior of passenger car.

  • PDF

공조 시스템용 DDC의 온라인 최적제어에 관한 연구

  • 안병천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1072-1078
    • /
    • 2001
  • The real time optimal control algorithm of the DDC controller for chilled water and supply air temperature set-point of heating, ventilating, air-conditioning and refrigeration systems has been researched for minimization of the total power which is consumed by the chiller, chilled water pump and air handing unit fan. The study has been done by using TRNSYS program in order to analyze the central cooling system in terms of the environmental variables such as indoor cooling lead and wet-bulb temperature. This optimal control alogorithm saves more energy and is suitable for real time on-line control in comparison with conventional method.

  • PDF

Caring Types in Mothers of Children with Athma : Q Methodology (천식 환아 어머니의 돌봄 유형: Q 방법론 적용)

  • Oh Won Oak
    • Child Health Nursing Research
    • /
    • v.6 no.1
    • /
    • pp.89-102
    • /
    • 2000
  • Asthma is one of the most common chronic disease of childhood. Although an improved understanding of the pathophysiology of asthma has had a positive impact on the treatment and management of the disease, there has been a gradual but significant increase in asthma mortality. Also, mother's caring type is the essential factor in management of the child with asthma. The purpose of this study is to identify and understand the caring patterns of mathers of children with Athma by Q methodology. As a research method, 35 Q-statements were collected through individual interviews and review of related literatures. 37 subjects were interviewed and the data were analyzed by the PC QUANL program with principal component analysis. The were 3 different caring types classified as follows : Type I was the therapeutic compliance obeying type, compliancing medication and preventing cold etc. Type II was the physical strengthening type, taking Chinese medicine and folk remedy etc. Type III was the environment control type, managing house and environment clearly and ventilating room air etc. Therefore, it needs considering above each type in nursing care of the family and children with asthma.

  • PDF

A Numerical Analysis on the Effect of Parameters for the Flow Rate through the Tunnel with Jet Fan Ventilating System (제트 홴 방식 환기시스템을 사용하는 터널의 환기량에 영향을 주는 인자에 대한 수치해석 검토)

  • 김사량;김기정;허남건;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.567-574
    • /
    • 2002
  • In the present study, ventilation flow rates and pressure rises through a road tunnel are simulated numerically using CFD with the various conditions such as roughness height, swirl angle of jet fan, entrance and exit effect and hub to tip ratio. By using a modified wall function, friction factor can be predicted under 10% of error with respect to the Moody chart for the circular pipe flow and 15%, for the present tunnel. For more precise design, the effects of the swirl angle and hub to tip ratio of jet fan, which is not included in the theoretical equation of pressure rise by jet fan are necessary to be considered.

The Measurement of the Indoor Air Quality in KTX Train (KTX 객실내 공기청정도 측정)

  • So, Jin-Sub;Lee, Sung-Uk;Park, Duck-Shin;Yoo, Seong-Yeon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1210-1213
    • /
    • 2006
  • Indoor air quality is an important determinant of human health and comfort. However, the complexity of pollution sources and the multitude of parties responsible for creating indoor exposures makes the improvement of air quality difficult. The KTX HVAC(Heating, Ventilating and Air-Conditioning) system is important facility to provide comfortable environment passenger service. The Ministry of Environment is planning to enforce$\square\square$Indoor Air Quality Management law in Public Facilities$\square\square$in year 2008. Hereupon, the train and the subway are included. In this research air quality in the KTX Train compartment has measured. As a result, The average amounts of PM10(particulate matters), $CO_2$(carbon dioxide)measured $20{\mu}g/m^3$, 1,097ppm in KTX respectively. There are compare to regulation the value is 10% for PM10 and 43% for $CO_2$. Thus, the indoor air quality of KTX train have been proved satisfy the recommendation the Ministry of Environment guidelines.

  • PDF