• Title/Summary/Keyword: Ventilated Space

Search Result 30, Processing Time 0.029 seconds

Formaldehyde Concentration Characteristics according to Type of Books and Furniture Arrangement in Bookstores (대형 서점 내 서적 종류 및 가구배치에 따른 포름알데히드 발생 특성)

  • Kang, Donghee;Jung, Chan Gwon;Kim, Sughwan;Lee, Sang-Jin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.23 no.4
    • /
    • pp.381-387
    • /
    • 2012
  • Utilization of underground floor is becoming the main issue of our society to maximize and diversify the potential of recent urban space. It has brought about the changes of underground floor. Recently there are lots of huge bookstores in these underground floor. Bleach, adhesive and ink used for manufacturing books pollute indoor air in bookstore. Therefore, the purpose of this study is to analyze indoor air quality in these large bookstores. Concentrations of carbon dioxide and formaldehyde in three large bookstores in Seoul were measured by presence and type of books and distance of main entrance which is well-ventilated. According to the data, space that places lots of volumes measured higher concentration of formaldehyde than that of non-existence books. Children's book section was measured more concentration of formaldehyde than other book section. Closer main entrance near outside, lower concentration of formaldehyde was measured. Concentration of carbon dioxide was affected by the number of people in bookstore.

  • PDF

Numerical Study of Particle Collection Performance of Electrostatic Precipitator Integrated with Double Skin Façade in Residential Buildings (주거건물용 이중외피 통합형 전기집진기의 미세먼지 집진성능 수치해석 평가)

  • Eom, Ye Seul;Choi, Dong Hee;Kang, Dong Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.73-82
    • /
    • 2018
  • The objective of this study was to evaluate particle collection performance of electrostatic precipitator (ESP) integrated with double skin façade in naturally ventilated residential buildings using numerical method. To evaluate the efficiency, computational fluid dynamics (CFD) simulation based on electric potential and Lagrangian method was applied. The CFD model was validated by comparing the simulated results with the experimental data including thermal characteristic of double skin façade (DSF) and particle removal characteristic of electrostatic precipitator. The validation results showed that the root mean square error (RMSE) between predicted values and measured values of velocity and temperature in intermediate space of DSF was 1.2%. The adequacy of ion space charge density and turbulent model were determined. The RMSE between predicted values and measured values of collection efficiency of ESP was 9.2%. In addition, the case study was performed to present the application of the numerical method based on validation results of ESP integrated with façade.

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

Natural Ventilation in High-Rise Building with Double Facades, saving or waste of Energy

  • Lee, Eung-Jik;Pasquay, Till
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.39-45
    • /
    • 2002
  • Double facades are built to allow natural ventilation in high rise buildings and buildings with high outside noise level. In high rise Buildings the gains in summer can be reduced by sufficient sun protection devices placed outside the rooms in the ventilated space between the inner and outer facade. To evaluate the energetic performance, three buildings with double facade were monitored for at least one year (Siemens Building in Dortmund/Germany, Victoria Insurance Company in Duesseldorf/Germany and RWE Tower in Essen/Germany). The results document the indoor climate, the boundary conditions for further planning and the possibilities for high rise buildings without or with little cooling facilities.

Design and Implementation of Space Adaptive Autonomous Driving Air Purifying Robot for Green Smart Schools (그린 스마트 스쿨을 위한 공간 적응형 자율주행 공기청정 로봇 설계 및 구현)

  • Oh, Seokju;Lee, Jaehyeong;Lee, Chaegyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.77-82
    • /
    • 2022
  • The effect of indoor air pollution on the human body is greater and more dangerous than outdoor air pollution. In general, a person stays indoors for a long time, and in a closed room, pollutants are continuously accumulated and the polluted air is better delivered to the lungs. Especially in the case of young children, it is very sensitive to indoor air and it is fatal. In addition, methods to reduce indoor air pollution, which cannot be ventilated with more frequent indoor activities and continuously increasing external fine dust due to Covid 19, are becoming more important. In order to improve the problems of the existing autonomous driving air purifying robot, this paper divided the map and Upper Confidence bounds applied to Trees(UCT) based algorithm to solve the problem of the autonomous driving robot not sterilizing a specific area or staying in one space continuously, and the problem of children who are vulnerable to indoor air pollution. We propose a space-adaptive autonomous driving air purifying robot for a green smart school that can be improved.

Extinguishment of Liquid Fuel Fire by Water Mist Containing Additives

  • Park, Jae-Man;Won, Jung-Il;Shin, Chang-Sub
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.24-29
    • /
    • 2005
  • An experimental study was presented for extinguishing characteristics of liquid fuel fire by water mist($Dv_{0.99}{\leq}200{\mu}m$) containing potassium acetate and sodium acetate trihydrate. To evaluate the extinguishing performance of water mist containing additives, the evaporation characteristics of a water droplet on a heated surface was examined. The evaporation process was recorded by a charge-coupled-device camera. Also, small-scale extinguishing tests were conducted for n-heptane pool fire in ventilated space. During the experiments, flame temperatures were measured, and concentrations of oxygen and carbon monoxide were analyzed by a combustion gas analyzer. The average evaporation rate of water droplet containing additives was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid-film and change of surface tension. In case of using additives, the fire extinguishing times was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium or sodium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4 MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

Estimation of Local Mean Ages of Air in a Room with Multiple Inlets (다중 급기구를 갖는 실내공간에서의 공기연령 산정방법에 관한 연구)

  • Han, Hwa-Taik;Shin, Cheol-Yong;Lee, In-Bok;Kwon, Kyeong-Seok;Kwon, Yong-Il
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.148-153
    • /
    • 2009
  • This paper considers the age of air in a ventilated space with multiple supply inlets. The local mean age of air at a point from one supply inlet is different from those from the other supply inlets. It is the purpose of the present paper to investigate theoretically the relations between the LMA's from each supply and overall combined LMA whether or not to trace the origins of supply air. Transient concentration distributions are calculated with a step-up injection of tracer gas at each supply inlet, and at both inlets simultaneously. The steady state concentration with a continuous tracer injection at a supply inlet works as a weighting factor for the corresponding LMA in calculating the average overall LMA from multiple inlets.

  • PDF

Survey on the Uses of Heating-Cooling Facilitis.Accessory Devices and Residents' Evaluation in Cheju Province (제주도 지역 냉난방 설비.보조기구 사용실태와 거주자의 평가)

  • 김봉애
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.5
    • /
    • pp.239-248
    • /
    • 1997
  • to design nature-affinitive, reasonable and effcient thermal environment plannings and facilities, the holding patterns of heating-cooling facilities·accessory devices and residents' evaluation in Cheju Province were surveyed as well as residents' understanding for them. Major findings of this study are summarized as follows: 1) In the cooling system, the percentage of air-conditioner possessor was 19.4%, which was lower possessive rate than mainland's. The location of air-conditioner was mainly public area. That is, 55.3% of the location is livingroom, and the rest was Anbang. the general cooling accessory device was a fan. It was frequently used at the children's room and the dining room. The possessive patterns of air-conditioner depend on the characteristics of residents, such as the academic carrier and the average monthly income. Characteristics of house for air-conditioner possess depend on the location, house type, the size of floor space. 2) In the heating system, individual heating system reached to 57.3%. Heating accessory devices were oil stove and electric heating blanket. Only 32.2% of survey population were holders. 3) Residents preferred better ventilated room arrangement, which was characteristic of subtropical areas. 4) The preferred condition for heating-cooling facilities and accessory devices were strong solidity, less air pollution, and less noise.

  • PDF

Effects of temperature and solution composition on evaporation of iodine as a part of estimating volatility of iodine under gamma irradiation

  • Yeon, Jei-Won;Jung, Sang-Hyuk
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1689-1695
    • /
    • 2017
  • As a part of evaluating the volatility of iodide ions subjected to gamma irradiation, $I_2$ evaporation experiments were performed with $I_2$ and $I^-$ mixed solutions in the temperature range $26-80^{\circ}C$ in an open, well-ventilated space. The evaporation of $I_2$ was observed to follow primarily first order kinetics, depending on the $I_2$ concentration. The evaporation rate constant increased rapidly with increase in temperature. The presence of $I^-$ slightly reduced the evaporation rate of $I_2$ by forming relatively stable $I_3^-$. The effect of $Cl^-$ at <1.0 wt% on $I_2$ evaporation was insignificant. The evaporation rate constants of $I_2$ were $1.3{\times}10^{-3}min^{-1}\;cm^{-2}$, $2.4{\times}10^{-2}min^{-1}\;cm^{-2}$, and $8.6{\times}10^{-2}min^{-1}\;cm^{-2}$, at $26^{\circ}C$, $50^{\circ}C$, and $80^{\circ}C$, respectively.

A Study on Job Satisfaction, Working Environment and Turnover Intention of Dental Technicians in Daegu Area (대구지역 치과기공사의 직무만족 및 작업환경과 이직의도에 관한 연구)

  • Park, Hong-Ryurn;Moon, Seon-Jeong
    • The Korean Journal of Health Service Management
    • /
    • v.6 no.4
    • /
    • pp.191-204
    • /
    • 2012
  • The purpose of this study was to provide basic data necessary for improvement by closely examining factors of having influence upon dental technicians' turnover. Questionnaire survey was conducted of 204 dental technicians who work at dental hospitals, clinics and dental laboratory rooms in Daegu area. The following conclusions were obtained. The satisfaction with job was high in job position in more than co-representative, in the whole and other task, and in less than 9 hours as for working hours. In the satisfaction with working environment, dissatisfaction was high in women, in the working career with 7~9 years, in chief level as for the job position in charge, in being responsible for porcelain in case of the duty field, and in more than 10 people as for the number of employees. The higher satisfaction with job satisfaction and working environment led to the lower turnover intention. Turnover intention was low in case of having ventilation fan & dust collector desk and in case of being well ventilated inside the workshop. As the above results, it is considered to be necessary for arranging institutional device of protecting dental technicians' health and reducing turnover through improving working environment such as forming comfortable environment of using the dust-collecting facilities and the ventilation facilities, wearing suitable individual protective gear and arranging the rest space.