• 제목/요약/키워드: Vent control

검색결과 84건 처리시간 0.022초

잔류공기조건에 따른 관 내 유동의 압력변화에 관한 실험적 연구 (An Experimental Study of Pressure Variation in Pipe Flow according to Residual Air Condition)

  • 박재곤;이경수;고주석;류시완
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.113-119
    • /
    • 2022
  • Sudden intrusion of a large amount of surface water into a flood defensive tunnel or pipeline system can compress the residual air. The compressed air may explode along with water through the inlet or air vent, resulting in hydraulic capacity degradation or safety hazards. This study aims to investigate the behavior of compressed air body in pipelines according to the residual air condition with a series of laboratory experiments measuring pressure variation. It has been found that flow characteristics and residual air conditions have a dominant influence on the magnitude and periodicity of the pressure variation. A proper measure to effectively control the residual air is required for securing the design capacity of flood defensive pipeline systems, since the peak pressure is predominantly affected by residual air conditions.

심해무인잠수정 해미래를 이용한 남마리아나 아크 해저화산 열수분출공 탐사 (Explorations of Hydrothermal Vents in Southern Mariana Arc Submarine Volcanoes using ROV Hemire)

  • 이판묵;전봉환;백혁;김방현;심형원;박진영;유승열;정우영;백세훈;김웅서
    • 한국해양공학회지
    • /
    • 제30권5호
    • /
    • pp.389-399
    • /
    • 2016
  • This paper presents the explorations of hydrothermal vents located in the Marina Arc and Back Arc Basin using the deep-sea ROV Hemire. These explorations were conducted by KRISO and KIOST to demonstrate the capability of Hemire in various applications for deep-sea scientific research. The missions included the following: (1) to search the reported vents, (2) conduct visual inspections, (3) deploy/recover a sediment trap and bait traps, (4) sample sediment/water/rock, (5) measure the magnetic field at the vent site, and (6) acquire a detailed map using multi-beam sonar near the bottom. We installed three HD cameras for precise visual inspection, a high-temperature thermometer, a three-component magnetometer, and a multi-beam sonar to acquire details of the bottom contour or identify vents in the survey area. The explorations were performed in an expedition from March 23 to April 5, 2016, and the missions were successfully completed. This paper discusses the operational process, navigation, and control of Hemire, as well as the exploration results.

3-DCS를 이용한 자동차 공기 분배장치의 도아 구동 기구의 공차 적합성 분석에 대한 연구 (Study of Tolerance Suitability of Door Operation Mechanism on Mobile Air Handing Unit Using 3-DCS Analysis)

  • 김종수;이대웅
    • 한국자동차공학회논문집
    • /
    • 제24권5호
    • /
    • pp.527-537
    • /
    • 2016
  • Recent automakers are trying to be more precise with the dimension check and moving parts to guarantee high quality and satisfy customer requirements. The aim of this paper is to investigate the design tolerance suitability of door operating mechanism linked arms, lever, and cam-shaft in a mobile air handling unit. These parts are complicated because doors, arms, lever and cam-shaft are connected nonlinearly in 3D. The current tolerance analysis method poses problems in design analysis because the moving doors are reasonably suitable for the AHU function. The 3-DCS analysis method provided useful results not only in establishing the inspection criteria for the quality control of products but also in enabling economical production. As a result, the vent door had $1.62^{\circ}{\sim}1.72^{\circ}$ and the defrost door had $0.84^{\circ}{\sim}0.9^{\circ}$ for the directly connected arms operating-type. For the lever connected arm operating-type, the foot door had $2.0^{\circ}{\sim}2.24^{\circ}$ tolerance, while the tolerance values satisfied the air flow volume distribution rate criteria in the AHU. Finally, the results have confirmed the design's tolerance suitability by using 3-DCS analysis at the early design stages. Reliability can be achieved by analyzing accumulated tolerance during the sub-parts assembly process and the moving mechanism linked especially by arms, lever, and cam-shaft.

음악치료(音樂治療)의 원리(原理)와 체질의학적(體質醫學的) 접근을 위한 검토 (A Review on Principles and Access Methods to Sasang Constitutional Medicine of Music Therapy)

  • 이지영;박성식
    • 사상체질의학회지
    • /
    • 제18권1호
    • /
    • pp.30-40
    • /
    • 2006
  • 1. Objectives The present study purposed to examine the contents and the principles of music therapy according to Oriental medicine theories in order to prove that music therapy is not a new research area but its principle is found in the long tradition of Oriental medicine. 2. Methods We investigate the possibility of music therapy based on Oriental medicine theories and examine the meanings of music therapy from the viewpoint of Oriental medicine. 3. Conclusions and discussions (1) The principles of music therapy are the principle of homogeneity, catharsis and balance. (2) When one’s mind changes, there are naturally occurred sounds, which are called Oseong (五聲: the oriental five voices exhalation, laughing, singing, wailing and groaning), and the notes defined by arranging the Oseong according to the principle of Ohaeng (五行: the oriental five phases wood, fire, earth, metal, water) are Oheum (五音: the oriental five musical notes Gakeum, Chieum, Gungeum, Sangeum and Wooeum.). If Eum (musical notes) is classified into Ohaeng, it can be divided into Gakeum, Chieum, Gungeum, Sangeum and Wooeum. (3) Change of Sinji (神志: consciousness) induces change of Gigi (氣機: function of Gi), which can change the character of voices. Oseong controls the functions of Ojang (五臟: the oriental five viscera) by ruling one’s Jeongji (情志: emotion). It can reduce the damage of the viscera caused by excessive vent of emotion resulted from unconscious expression of Oseong - Hoseong (呼聲: exhalation), Soseong (笑聲: laughing), Gaseong (歌聲: singing), Gokseong (哭聲: wailing) and Sinseong (呻聲: groaning). (4) Yijeongseungjeong (以情勝情: Control emotion with emotion) therapies, which suppresses an emotion by stimulating another, include Noseungsabeop (怒勝思法: Control anxiety with anger), Heeseungbibeop (喜勝悲法: Control sorrow with joyfulness), (思勝恐法: Control fear with anxiety), Biseungnobeop (悲勝愁法: Control anger with sorrow) and Gongseungheebeop (恐勝喜法: Control joyfulness with fear). (5) Seongeum (聲音: voices and musical notes) can be applied to a stimulation method that not only harmonizes the rhythm of living organs but also controls the occurrence of diseases caused by mutual Pyeonseongpyeonsoi (偏盛偏衰: relative preponderance and weakness) through direct induction of the strength and weakness of Gi function of the oriental five viscera in a human body according to the individual character. Sounds preferred by the patient, the material of an instrument selected by the patient, the character of rhythm and music expressed by the patient and the sound or voice uttered frequently by the patient can be considered in diagnosis and treatments for the patient’s body and mind.

  • PDF

Control Indian meal moth Plodia interpunctella by gas treatment

  • Han, Gyung Deok;Kwon, Hyeok;Jin, Hyun Jung;Kum, Ho Jung;Kim, Bo Hwan;Kim, Wook
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.45-45
    • /
    • 2017
  • The Indian meal moth, Plodia interpunctella, is one of the most important pests of stored food in the food processing industry worldwide. To control the Indian meal moth, methyl bromide, phosphine, high carbon dioxide, sulfuryl fluoride and plant essential oil fumigation have been considered. However, these treatments have disadvantages. For example, depleting the ozone layer, showing resistance in insect, low control efficacy or need high cost for treatment. Chlorine dioxide ($ClO_2$) is strong disinfectant and insecticide. The gas caused a malfunction in enzymes. The oxidative stress induced by $ClO_2$ gas treatment damaged to a physiological system and all life stages of P. interpunctella. The gaseous $ClO_2$ is a convincing alternative to methyl bromide for controlling P. interpunctella. The gaseous $ClO_2$ was generated by a chlorine dioxide generator (PurgoFarm Co., Ltd., Hwasung, Korea). It generated highly pure $ClO_2$ gas and the gas blown out through a vent into a test chamber. Gas entry to the chamber was automatically controlled and monitored by a PortaSene II gas leak detector (Analytical Technology, Collegeville, PA, USA). The properly prepared eggs, larvae, pupae, and adults of P. interpunctella were used in this experiment. Data were analyzed using SAS 9.4. Percentage data were statistically analyzed after arcsine-root transformation. Analysis of variance was performed using general linear model, and means were separated by the least significant difference test at P < 0.05. Fumigation is an effective management technique for controlling all stages of P. interpunctella. We found that $ClO_2$ gas treatment directly effects on egg, larvae, pupae and adults of P. interpunctella. The gas treatment with proper concentration for over a day achieved 100 % mortality in all stages of P. interpunctella and short time treatment or low concentration gas treatment results showed that the egg hatchability, pupation rate, and adult emergency rate were lowered compare with untreated control. Also, abnormal pupae or adult rate were increased. Gaseous $ClO_2$ treatment induced insecticidal reactive oxygen species (ROS), and it resulted in fatal oxidative stress in P. interpunctella. Taken together, these results showed that exposure proper concentration and time of the gas control all stages of P. interpunctella by inducing fatal oxidative stress. Further studies will be required to apply the gas treatment under real-world condition and to understanding physiological reaction in P. interpunctella caused by oxidative stress.

  • PDF

스크린도어가 설치된 대심도 지하역사의 제연 실험 - 터널 송풍기에 의한 제연의 효과 분석 (Smoke Control Experiment of a Very Deep Underground Station Where Platform Screens Doors are Installed - Analysis on Smoke Control Performance by Fans equipped in Tunnel)

  • 박원희;김창용;조영민
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제9권9호
    • /
    • pp.721-736
    • /
    • 2019
  • 본 논문에서는 대심도에 위치한 지하역사(지하 6층) 및 터널에서 화재가 발생했을 경우 제연설비 작동에 따른 연기의 거동을 측정하였다. 열풍기를 이용하여 열부력 효과를 구현한 연기발생장치를 이용하여 화재연기를 생성하였다. 화재발생 위치는 승강장 위 및 스크린도어 외부에 위치한 터널부의 승강장 위의 2가지 위치를 선정하였다. 승강장 화재발생시 승강장에 설치된 환기구를 통하여 연기가 배출되도록 하는 제연모드가 일반적인데 본 연구에서는 승강장 양단에 위치한 터널부의 환기구를 통한 배기도 같이 동작되도록 설정하여 실험을 수행하였다. 다양한 위치에서 연기농도 및 풍향풍속을 측정하였고 화면을 취득하여 연기의 이동 및 제연을 분석하였다. 승강장 내부에서 화재가 발생하였을 경우와 선로부에서 화재가 발생하였을 경우 승강장의 송풍기의 제연모드 동작과 터널의 송풍기의 배연 동작으로 인하여 연기배출이 원활하였고 화재 발생 인근 구역으로의 연기전파가 억제되었다. 본 연구에서 제시한 승강장 및 승강장 양단부의 터널에 적용되는 송풍기를 같이 운전하는 제연모드를 통하여 승강장 화재 및 화재열차 정차시 화재 연기로부터 승객들에게 보다 안전한 대피환경을 제공할 수 있을 것이다.

냉매 내 공기혼입에 따른 에어컨 시스템의 냉각성능 저하 (Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제34권6호
    • /
    • pp.470-475
    • /
    • 2009
  • This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.

A Bio-fluidic Device for Adaptive Sample Pretreatment and Its Application to Measurements of Escherichia coli Concentrations

  • Choi Won-Jae;Park Je-Kyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권1호
    • /
    • pp.54-60
    • /
    • 2006
  • In this paper, we describe a bio-fluidic device for adaptive sample pretreatment, in order to optimize the conditions under which absorbance assays can be conducted. This device can be successfully applied to the measurement of Escherichia coli (E. coli) concentrations using adaptive dilution, with which the dilution ratio can be adjusted during the dilution. Although many attempts have been previously made to miniaturize complex biochemical analyses at the chip scale, very few sample pretreatment processes have actually been miniaturized or automated at this point. Due to the lack of currently available on-chip pretreatments, analytical instruments tend to suffer from a limited range of analysis. This occasionally hinders the direct and quantitative analysis of specific analyses obtained from real samples. In order to overcome these issues, we exploit two novel strategies: dilution with a programmable ratio, and to-and-fro mixing. The bio-fluidic device consists of a rectangular chamber constructed of poly(dimethylsiloxane) (PDMS). This chamber has four openings, an inlet, an outlet, an air control, and an air vent. Each of the dilution cycles is comprised of four steps: detection, liquid drain, buffer injection, and to-and-fro mixing. When using adaptive sample pretreatment, the range in which E. coli concentrations can be measured is broadened, to an optical density (O.D.) range of $0.3{\sim}30$. This device may prove useful in the on-line monitoring of cell concentrations, in both fermenter and aqueous environments.

발전소의 스팀제어용 유압서보 액추에이터의 공기배출 밸브에 관한 연구 (A Study on the Air Vent Valve of the Hydraulic Servo Actuator for Steam Control of Power Plants)

  • 이용범;이종직
    • 대한기계학회논문집B
    • /
    • 제40권6호
    • /
    • pp.397-402
    • /
    • 2016
  • 원자력 발전소와 화력 발전소에서는 양질의 전기를 생산하기 위해서는 발전기에 연결된 고압 및 저압 증기터빈에 최적량의 증기를 공급하여야 한다. 터빈에 증기를 공급하거나 차단하는 특수한 밸브인 터빈출력제어장치를 사용하고 있으며, 이 터빈출력제어장치는 유압서보 액추에이터로 구동 된다. 발전소에서는 유압시스템에서 생성되는 기체로 인하여 유압서보 액추에이터의 성능이 저하되거나, 생성된 기체가 압축되면서 발생하는 열로서 씰을 태우고 마모를 증가시켜서 빈번한 고장이 유발된다. 일부 발전소에서는 고정형 오리피스를 사용하여 공기를 배출하고 있지만 많은 유량배출에 따른 동력 손실과 빈번하게 작동되는 펌프, 전기모터 및 밸브 등의 고장을 발생시킨다. 본 연구에서는 기존의 고정형 오리피스와 같이 초기에 많은 량의 공기를 배출하고 정상운전에서는 매우 미세한 유량만 통과 시킬 수 있는 부하 감응형 공기 배출밸브를 모델링하고 해석하여 장착함으로서 유압서보 액추에이터의 제어 정밀성 확보와 기체 압축으로 인한 고장을 방지할 수 있게 하였다.

스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석 (Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform)

  • 박원희;김창용;조영민;권태순;이덕희
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권7호
    • /
    • pp.485-496
    • /
    • 2018
  • 본 논문에서는 스크린도어가 설치되어 있는 지하역사 승강장에서 화재가 발생시 승강장 환기실에 설치된 송풍기의 작동에 따른 연기거동을 실험적인 방법으로 측정하였다. 스크린도어가 닫힌 승강장에서 모의화재 발생시 승강장의 제연설비가 작동하지 않은 경우와 작동하는 경우에 제연 특성을 비교하였다. 화재연기를 모사하기 위하여 연기발생기에서 발생한 연기를 열풍기를 이용하여 가열하였다. 화재연기를 정량적으로 측정하기 위하여 연기농도계를 이용한 광투과도를 측정하였다. 스크린도어가 닫혀져있고 지하역사의 제연설비가 작동되지 않는 경우 승강장에 화재가 발생하면 연기가 승강장 내부에 축적되어 승객의 피난이 매우 어려우며, 매우 위험한 상황으로 연결될 수 있음을 확인할 수 있었다. 반면에 역사의 제연설비를 가동한 조건에서는 승강장 화재에 의해 발생한 연기가 역사의 제연설비를 통하여 외부로 빠져나가며, 대합실에서 승강장 방향으로 기류가 형성되어 승강장 승객이 대합실 방향으로 대피하는 것이 가능함을 확인할 수 있었다. 후속 논문에서는 승강장 인접부에 위치한 터널환기구를 통한 터널 제연의 병행효과에 대하여 다룰 예정이다.