• Title/Summary/Keyword: Vent Analysis

Search Result 158, Processing Time 0.037 seconds

Analysis of Dynamic Characteristics and Performances of Vent-Relief Valve (산화제 벤트/릴리프밸브의 동특성 해석 및 작동성능분석)

  • Jang, Je-Sun;Koh, Hyeon-Seok;Han, Sang-Yeop;Lee, Kyung-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.741-747
    • /
    • 2010
  • Vent-relief valve performed as a safety-valve combination for liquid propellant feeding system of space launch vehicle, which can vent the vaporized oxygen vapor during both filling cryogenic oxidizer into tank and flight. We have designed vent-relief model by using the AMESim code to predict dynamic characteristics and simulate pneumatic behavior of valve. To validate valve model we have compared by opening time in vent model, and opening/closing pressure by mathematical methods and improved the accuracy through numerical flow analysis by using FLUENT code. In this study, we had verified design parameters and analyzed operating performances. We can use these analysis results to precedent development study on propellant feeding system of Korea Space Launch Vehicle.

  • PDF

Design and Development of Vent Relief Valve for Oxidizer Tank (산화제 탱크용 벤트릴리프밸브 설계 및 개발)

  • Koh, Hyeon-Seok;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.854-856
    • /
    • 2011
  • A vent relief valve for oxidizer tank has been designed for liquid propellant feeding system of the space launch vehicle. The vent relief valve ensures oxidizer tank ventilation during filling and its protection from overpressure after filling. Tank ventilation during filling is ensured by vent valve and tank protection is ensured by combined operation of relief valve and vent valve. Numerical analysis predicted that pneumatic behavior and dynamic characteristics met the valve requirements. After manufacturing the prototype model, we have been conducting the tests to evaluate the performance of the vent relief valve.

  • PDF

An Analysis of Investigation Movies of S/C Vent Area in the Unit 2 Reactor Building Basement floor of Fukushima Daiichi Nuclear Power Plant (후쿠시마 제 1 원자력발전소 2 호기 원자로 건물 지하의 S/C Vent 관 조사영상 분석)

  • Cho, Jai-Wan;Jeong, Kyung-Min
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.05a
    • /
    • pp.311-314
    • /
    • 2013
  • 본 논문에서는 일본의 (주) 동경전력이 공개한 후쿠시마 제 1 원자력발전소 2 호기 원자로건물 지하에 위치한 S/C (Suppression Chamber) 주변의 Vent 관 조사 동영상들을 분석하였다. S/C 는 donut (환형) 모양의 구조물로 PCV (격납용기) 와 연결된 8 개의 Vent 관을 통해 원자로의 압력을 억제한다. 후쿠시마 사고 원자로의 용융 핵연료를 인출하기 위해서는 원자로 압력용기 및 PCV에 물을 채워서 방사선 선량율을 떨어뜨려야 한다. 물을 채운 후에 누설이 되면 안되기 때문에, PCV 와 S/C 사이에 연결된 Vent 관에 대한 방사능 오염수의 누설지점을 찾는 것이 중요하다. 이를 위한 사전공정으로 (주) 도시바의 4 족보행 로봇 탑재 카메라를 이용하여 8 개 Vent 관 모두를 육안 검사하였다. (주) 동경전력이 공개한 영상을 분석한 결과 고선량 감마선에 의한 Speckle 들이 관측되었다. 본 논문에서는 이러한 Speckle 분포의 특성을 분석하여 S/C 와 PCV 를 연결하는 8개 Vent 관중 방사능 오염물질이 많은 곳을 특정하고자 하였다.

Dynamic PIV analysis of High-Speed Flow from Vent Holes of Fill-Hose in Curtain type Airbag (Dynamic PIV 기법을 이용한 커튼에어백 Vent Hole 고속유동 해석)

  • Jang, Young-Gil;Choi, Yong-Seok;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.17-20
    • /
    • 2006
  • Passenger safety is fundamental factor in automobile. Among much equipment for passenger safety, the air bag system is the most fundamental and effective device. Beside of the front air bag system which installed on most of all automobiles, a curtain-type air bag is increasingly adapted in deluxe cars fur protecting passengers from the danger of side clash. Curtain type airbag system consists of inflator housing, fill hose, curtain airbag. Inflator housing is a main part of the curtain-type air bag system for supplying high-pressure gases to deploy the air bag-curtain. Fill hose is a passageway to carry the gases from inflator housing to each part of curtain airbag. Therefore, it is very important to design the vent holes of fill hose for good performance of airbag deployment. But, the flow information from vent holes of fill hose is very limited. In this study, we measured instantaneous velocity fields of a high-speed flow ejecting from the vent holes of fill hose using a dynamic PIV system. From the velocity Held data measured at a high frame-rate, we evaluated the variation of the mass flow rate with time. From the instantaneous velocity fields of flow ejecting from the vent holes in the initial stage, we can see a flow pattern of wavy motion and fluctuation. The flow ejecting from the vent holes was found to have very high velocity fluctuations and the maximum velocity was about 480m/s at 4-vent hole region. From the mass flow rate with time, the accumulated flow of 4-vent hole has occupied about 70% of total flow rate.

  • PDF

Development of a Vent Analysis Method for Multiple Compartments Connected Through Multiple Ports (다중 Port로 연결된 다중 격실 Vent 해석 기법 개발)

  • Ok, Ho-Nam;Kim, In-Sun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.547-550
    • /
    • 2006
  • An analysis method is developed for the prediction of venting in multiple compartments which are connected in series or parallel through multiple ports. The existing method by the authors is modified to remove the limitation in number of ports and compartments, and the more general polytropic relation or solution of the additional energy equation replaces the previous isentropic relation allowing the prediction of pressure rise in addition to pressure drop. The accuracy of the method is verified by comparison with the results by NASA Flap code for the problem of pressure drop in a payload in the Space Shuttle cargo bay. It is expected that this method will be a useful tool in prediction of the pressure variation in a payload or payload capsule without mentioning the payload fairing itself.

  • PDF

Design of Vent Relief Valve for Bi-level Pressure Setting of Oxidizer Tank (산화제 탱크 2단계 압력 설정을 위한 벤트/릴리프밸브 설계)

  • Koh, Hyeonseok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1051-1053
    • /
    • 2017
  • We have designed the vent relief valve to set bi-level safety pressure for oxidizer tank. The minimum cavity volume was calculated to reduce the pressure deviation, and the valve operation characteristics was analyzed by using modeling. We have a plan to manufacture the validation model based on the analysis results.

  • PDF

Thermal Dissipation Performance of the Ventilated Brake Disc having Helical Grooved Vent (나선형 홈이 있는 벤틸레이티드 브레이크 디스크의 열 방출 성능)

  • Choi, Young;Choi, Ju-Won;Kim, Hyung-Man;Seo, Yong-We
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.3
    • /
    • pp.117-123
    • /
    • 2004
  • A brake disc with helical grooved vent in radial direction is proposed for the improvement of thermal dissipation. The heat transfer phenomenon is analyzed far both the proposed disc and the conventional one using finite element method. The thermal dissipation is considerably influenced by the geometrical differences of the brake discs. The results of the analysis show that the proposed brake disc with helical grooved vent has the improved performance to dissipate the thermal energy more effectively.

Failure Analysis of Air Vent Connected with Heat Supply Pipeline Under Manhole (맨홀에 설치된 지역난방 열공급관 에어벤트의 전단부 파손 원인 규명)

  • Cho, Jeongmin;Chae, Hobyung;Kim, Heesan;Kim, Jung-Gu;Kim, Woo Cheol;Jeong, Joon Cheol;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.196-202
    • /
    • 2020
  • The air vent connected to a heat supply pipeline in the district heating system has been used to eliminate the existing air in the pipe, which has a detrimental effect on corrosion durability and heat efficiency. Recently, the air vent installed under a manhole for 22 years was corroded and several pinholes were detected in the front-end of the air vent. To identify the cause of the failure, thickness reduction, corrosion products, and water quality were examined. The corrosion damage was significant at the outside of the front-end of the air vent where the insulator was covered. While a thin oxide layer was formed in the interior of the tube, the coarse and porous corrosion products consisting of magnetite and hematite were found externally. Water flowing into the thermal insulator was absorbed by the insulator following hydrolysis. The hydrolyzed insulator ejected the corrosion factors such as Cl-, SO42-, and NH4+. The findings suggest that the corrosion under insulation due to rain water is the main cause of the underlying failure in the air vent.

Analysis of Smoke Behavior in Fire within Real-scale Theater Using FDS: Influences of Fire Curtain and Natural Smoke Vent Area (FDS를 이용한 실규모 공연장 무대 내 화재 시 연기 거동 분석: 방화막 및 자연배출구 면적의 영향)

  • Kim, Jae Han;Lee, Chi Young;Jeong, Lee Gyu;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.7-14
    • /
    • 2018
  • This study investigated numerically the influences of fire curtain and natural smoke vent area on smoke movement in the stage fire of a theater using FDS (Fire Dynamics Simulator). The dimension of the theater stage was 31 m in width, 34 m in depth, and 32 m in height. The area ratios between the natural smoke vent and stage were approximately 10%, 8%, 5%, and 1%. The gap distance between the fire curtain and proscenium wall was 0.5 m. The fire curtain and natural smoke vent area were observed to affect significantly the behavior of smoke movement to the auditorium and the mass flow rates of inflow and outflow through the natural smoke vent and proscenium opening. In addition, under the same natural smoke vent area, the pressure in the stage with a fire curtain was lower than that without a fire curtain.