• 제목/요약/키워드: Venetian blind system

검색결과 15건 처리시간 0.028초

블라인드연동 LED조명의 조광제어에 따른 재실자의 밝기 변화 인식에 관한 연구 (A Study on the Perception of the Brightness Change according to Daylight Responsive LED Dimming Systems and Venetian Blind)

  • 염현주;김인태;최안섭
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.44-53
    • /
    • 2013
  • This study has attempted to investigate how subjects perceive changes of brightness and their visual comfort according to daylight responsive LED(Light Emitting Diode) dimming systems in the office with venetian blind. Two studies was conducted. First study is that how subjects perceive changes of brightness and their visual comfort depending on angle control method of the venetian blind while the workplane illuminance level is being maintained through daylight responsive LED dimming system. Second study is that how subjects perceive changes of brightness and their visual comfort depending on the amount of daylight penetrated into the building while the illuminance level is being maintained through daylight responsive LED dimming system. The results of this study could be proposed as basic data in the control of the venetian blind and LED lighting in consideration of their perception on changes of brightness and visual comfort.

건물에너지 저감을 위한 향별 슬랫형 블라인드의 최적각도 제어 알고리즘 산출 (Optimized slat angle control algorithm prediction of venetian blind depending on window orientation for energy saving)

  • 권혁주;이금호;이광호
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.99-106
    • /
    • 2017
  • Purpose: Most modern office buildings adopt the curtain wall system in order to provide occupants with the sense of openness and high-technology, which requires large window area. As a result, the amount of solar radiation increases, negatively affecting cooling load during the summer and increasing energy costs. However, the performance of window itself is not sufficiently controllable parameter to control thermal comfort and solar radiation. Therefore, a shading device such as venetian blind is required to control them and thus a variety of studies have been performed thus far. So, the purpose of this study is to improve the performance of blind through the development of blind control algorithm. Method: Among various input variables for the control of venetian blinds, the vertical solar radiation has been selected in this study as the primary input variable and the optimal control algorithm for venetian blinds were developed for each window orientation. Result: The developed optimal control algorithm has a positive effect on building energy savings.

베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석 (Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles)

  • 신화영;김곤;김정태
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.

실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구 (A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices)

  • 김태중;강재식;박준석
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.89-99
    • /
    • 2014
  • The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient (SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to $-45^{\circ}$, $0^{\circ}$, and$-45^{\circ}$. For the roll screen, measurements were taken with the roll screen in the closed position. In result, the venetian blind reduced SHGC by 21.2~28.4% at $45^{\circ}$, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind $-45^{\circ}$, $0^{\circ}$ and $45^{\circ}$, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.

블라인드를 고려한 여름철 소규모 사무소 건물의 냉방 및 조명에너지 평가 (The Summer Cooling and Lighting Energy Performance Evaluation of Small Office Buildings with Venetian Blinds)

  • 정유근
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.39-45
    • /
    • 2013
  • The daylighting control system has to be applied to prevent the excessive incident daylight and reduce energy use. As the one of the most useful daylighting control systems, the blind system is simple and easy to install on the window for small office buildings. This study aims to evaluate the summer energy performance of small office buildings by venetian blinds and energy saving strategy of ministry of knowledge economy in korea. For the study, the simulations have been executed on blind installation conditions and lighting control methods. As results, the energy loads cut down 22 to 25(%) by using blind energy. Also, the efficient shows high on EMS system and low on $45^{\circ}$ slat angles. Also, using energy saving strategy can reduce about 13(%) energy load.

RADIANCE 프로그램을 이용한 베네치안 블라인드의 차양특성 분석 (Analyzing Shading Characteristics of Venetian Blinds Using the RADIANCE Program)

  • 송규동;김민성;김지현
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.3-9
    • /
    • 2005
  • Venetian blinds are used with windows to improve the uniformity ratio of illuminance and interior daylighting distribution under direct sunlit conditions. The main objective of Venetian blinds shading system is to obstruct direct sunlight and at the same time allow daylight to penetrate into the room. Venetian blinds would have greater effect on the interior daylighting condition under clear sky which has both skylight and sunlight than overcast sky which has only skylight. However, due to the lack of data, design and evaluation tools, it is difficult for architects to choose or install venetian blinds during the building design stages. The purpose of this study was to develop an analysis method for shading and daylighting effects of Venetian blinds using the RADIANCE program. The major variables related to the venetian blinds included blinds's slat angle and the ratio of slat width to window height, the radius slat of curvature and the building azimuth. In this study, a series of parametric physical mock-up model measurements and genblinds command in the RADIANCE simulations. The results of this study will provide building designers with the design data at early design stages.

건물에너지성능 및 불쾌현휘를 고려한 고정형 블라인드의 최적 슬랫각도 도출 방법에 관한 연구 (A Elicitation Method of Optimum Slat Angle of Fixed Venetian Blind Considering Energy Performance and Discomfort Glare in Buildings)

  • 박장우;윤종호;오명환;이광호
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.107-112
    • /
    • 2012
  • The purpose of this study is to determine the optimum slat angle of the venetian blind which was applied at an outer skin of a curtain-wall system. The evaluation of the blind slat angle was performed in terms of the comfortable visual environment and decreased energy consumption. The office building prototype was considered for the analysis and simulation variables include application of blind, blind slat angle and dimming control of lighting. The annual energy consumption and incidence rate of discomfort glare were analyzed using EnergyPlus which is developed by the U. S. Department of Energy for the detailed building energy simulation. As a result, it turns out that when the blind (reflectance: 0.5) was installed, the annual energy consumption was greater than that of the base model. However, when the dimming control was applied, the maximum energy saving of 16.3% could be achieved at a slat angle of $0^{\circ}$. In addition, in case of the base model, the incidence rate of discomfort glare was 84%, while the case of the blind with the slat angle of $0^{\circ}$ showed that the incidence rate of discomfort glare was 42.4%. Consequently, the results showed that the slat angle of $55^{\circ}$ with dimming control was the optimum strategy for the comfortable visual environment and decreased energy consumption.

공동주택의 에너지 부하량 저감을 위한 블라인드 운영스케줄 검토 (Blind Optimal Operating Schedule for Reviewing the Energy Load Reduction of Apartment House)

  • 마쥔챠오;이준기;김성훈;이갑택;이경희
    • 동력기계공학회지
    • /
    • 제20권4호
    • /
    • pp.63-68
    • /
    • 2016
  • In this study, through portion of the blind control which the user can adjust the deration and the main loads, night for energy reduction during the review of the energy difference between the cooling and heating load periods in order to present the best operation schedules of the blind control. The result, Cooling period, the venetian blind is installed the day or the day and night CASE adjusted to $0^{\circ}$ was identified as optimal for the operating schedule. Heating period, the day, without installed the blinds, the Venetian blind is installed only at night CASE adjusted to $0^{\circ}$ or $45^{\circ}$ angle of the slats, which have been identified as optimal for the operating schedule.

재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략 (Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance)

  • 오명환;윤종호;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF

공기식 집열창 시스템이 설치된 건물의 동적부하 해석 (Time Dependent Thermal Load Analysis of the Building with an Airflow Window System)

  • 조성환;박상동
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.82-95
    • /
    • 1992
  • It has been known that the application of an airflow window system reduces the energy consumption compared with conventional double pane window in a building. But how to analyze thermal load in a building with an airflow window system has not been well known. so two kinds of method (Mode 1 and Mode 2) to analyze time dependent thermal load of the building with an airflow window system are presented in this study. The results of load analysis about the model building(total area : $4521m^2$, 3 floors) by Mode 2 show that the maximum cooling and heating load in a building with an airflow window system are decreased about 12-17% and about 19.5% than with double pane glass window, and yearly energy consumption with an airflow window system is saved about about 20% than with double pane glass window.

  • PDF