• Title/Summary/Keyword: Velocity Imaging

Search Result 313, Processing Time 0.033 seconds

Statins Have No Role in Preventing the Progression of Aortic Valve Sclerosis

  • Seo, Jeong-Hun;Chun, Kwang-Jin;Lee, Bong-Ki;Cho, Byung-Ryul;Ryu, Dong Ryeol
    • Journal of Cardiovascular Imaging
    • /
    • v.26 no.4
    • /
    • pp.229-237
    • /
    • 2018
  • BACKGROUND: Statins are thought to have little effect on the progression of aortic stenosis, but the data on their role in patients with aortic valve sclerosis (AVS) are limited and inconsistent. METHODS: We retrospectively analyzed 541 consecutive patients (214 men, age: $70{\pm}11$ years) with AVS. Each patient underwent two or more electrocardiography examinations at least 6 months apart at Kangwon National University Hospital from August 2010 to August 2015. AVS is defined as irregular thickening of the leaflets, focal increases in echogenicity and minimal elevation of the peak aortic valve velocity (> 1.5 and < 2 m/s). The progression rate of AVS was expressed as the increase in peak velocity per year (m/s/yr). RESULTS: The mean follow-up duration was $24.9{\pm}13.3$ months in the statin-treated group and $24.1{\pm}12.4$ months in the non-statin-treated group (p = 0.460). There were no differences between the statin-treated and non-statin-treated groups in mean age, gender or smoking status. Relative to the non-statin-treated group, a higher number of patients in the statin-treated group had hypertension, diabetes, ischemic heart disease, and stroke. The progression rate of AVS did not differ between the statin-treated and non-statin-treated groups ($0.012{\pm}0.340m/s/yr$ vs. $0.014{\pm}0.245m/s/yr$, p = 0.956). Multivariate analysis showed initial peak aortic jet velocity was significantly associated with AVS progression (${\beta}=0.153$, p = 0.009). CONCLUSIONS: Our study demonstrated that statins had no effect on the progression of AVS. However, well-designed studies are needed to define the prognosis and management of AVS.

Comparison Study between Myocardial Velocity obtained from Gated Myocardial SPECT and Myocardial Functional indices with a Focus on Myocardial Perfusion (게이트 심근 관류 SPECT에서 구한 심근 속도와 심근 관류를 중심으로 한 심근 기능 지표와의 비교연구)

  • Ha, Jung-Min;Jeong, Shin-Young;Bom, Hee-Seung;Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.386-394
    • /
    • 2009
  • Purpose: We aimed to assess the myocardial velocity on gated myocardial perfusion SPECT (gated MPS), to compare myocardial velocity between patients without coronary artery disease (CAD) and CAD patients and to assess the correlation of myocardial velocity and perfusion and wall thickening on CAD group. Materials and Methods: Seventeen patients without CAD (M:F=9:8, mean age $61.8{\pm}11.1$ yrs: group A) and thirty-nine patients with CAD (M:F=18:21, mean age $66.9{\pm}8.1$ yrs : group B) had undergone one-day adenosine stress gated MPS. In twenty segment model, 12 segments (except apical and basal segments) of each patient were included. We obtained systolic and diastolic gate ratio in left ventricular volume curve by eight frames per cardiac cycle on gated MPS. Using the systolic and diastolic gate ratio and R-R time of each patient, we obtained systolic and diastolic time ratio. The myocardial velocity was defined as wall thickening over systolic or diastolic time. Results: We presented normal range of myocardial velocities according segments and territories of coronary artery. The myocardial velocity of group B was significantly lower than group A (p=0.00). There was no significant difference between the myocardial velocity of group B with preserved EF and group A. The stress systolic velocity significantly correlated with regional myocardial perfusion in group B with preserved EF (p=0.00) as well as decreased EF (p=0.01). In group B, stress perfusion of segments which had decreased wall thickening and decreased myocardial velocity was significantly lower than segments which had decreased wall thickening and preserved myocardial velocity (p=0.01). Conclusion: The new functional index of velocity will be used as an useful of gated MPS.

Diastolic Function in Patients with Hypertrophic Cardiomyopathy: Evaluation Using the Phase-contrast MRI Measurement of Mitral Valve and Pulmonary Vein Flow Velocities (비대성심근증 환자의 이완기능평가: 승모판과 폐정맥 유속을 측정한 위상차 MRI의 이용)

  • Kim, Eun Young;Choe, Yeon Hyeon;Kim, Sung Mok;Lee, Sang-Chol;Chang, Sung-A;Oh, Jae K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.314-322
    • /
    • 2014
  • Purpose: Diastolic dysfunction is a common problem in patients with hypertrophic cardiomyopathy (HCM). The purpose of this study was to assess the role of MRI in the assessment of diastolic function using mitral valve and pulmonary vein flow velocities in HCM patients. Methods and Results: Phase-contrast MRI (mitral valve and pulmonary vein) and transthoracic echocardiography was successfully performed for 59 HCM patients (44 men and 15 women; mean age, 51 years). Forty-nine patients had a diastolic dysfunction; grade 1 (n = 20), grade 2 (n = 27), and grade 3 (n = 2) using echocardiography, and ten patients had normal diastolic function. The transmitral inflow parameters (E, A, and E/A ratios) obtained by MRI showed positive correlation with the same parameters measured by echocardiography (Pearson's r values were 0.47, 0.60, and 0.75 for E, A, E/A, respectively, all P < 0.001). With the flow information of the pulmonary vein from cardiac MRI, pseudo-normalized pattern (n = 8) could be distinguished from true normal filling pattern (n = 17), and the diastolic function grades by cardiac MRI showed moderate agreement with those of echocardiography (kappa value = 0.45, P < 0.001). Conclusions: Assessment of left ventricle diastolic function is feasible using phase-contrast MRI in HCM patients. Analysis of pulmonary vein flow velocity on MRI is useful for differentiating pseudo-normal from normal diastolic function in HCM patients.

Survey on the Ratio of Kitchen to Total Space and Ventilation System Capacity of Kitchens through Case Studies in Korean Foods Restaurants (사례 조사를 통한 한식 음식점의 주방면적 비율과 환기시설의 적정성 조사)

  • Chang, Hyeja;Choi, Gyunggi;Wang, Taehwan;Kwak, Tongkyung
    • Korean journal of food and cookery science
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 2015
  • For the globalization of Korean food restaurants, the kitchens should be equipped with proper ventilation systems and space to keep clean and ensure food safety. This study aimed to examine the ratio of kitchen to total space of restaurant and the suitability of the ventilation systems employed at Korean food restaurants. Data were collected by on-site survey of 12 Korean foods restaurants in Seoul. Length and width of the restaurants were measured with scale. Temperatures and air velocity around the heating equipment, working area, and hood were measured with a thermal imaging camera anemometer and thermometer. Statistical analyses were conducted with the SPSS program. The average space of the restaurants was $25.7m^2$. The ratio of kitchen to space was 0.22 for restaurants sized $32m^2$, 0.28 for $33-66m^2$, 0.21 for $66.1-99m^2$, 0.16 for $99.1-148.5m^2$, and 0.35 for those above $148.5m^2$. Average maximum and minimum air velocity around the hood were 0.28 m/sec and 0.22 m/sec, respectively. Under these conditions, the temperature of the working area was $41^{\circ}C$, presenting an uncomfortable indoor temperature for kitchen employees to work. When classifying 3 groups based on the minimum and maximum air velocity, the temperatures near the cooking area and in the hood of the restaurants showed significant differences among the three groups. When the maximum air velocity was over 0.3 m/sec, the temperature of the cooking area was as $30.1^{\circ}C$, showing a significantly lower temperature (p<0.01). Based on these results, the kitchen space rate of 0.25 to the total space and a ventilation system maintaining a maximum air velocity over 0.3 m/sec were recommended for ensuring the food safety of Korean foods restaurants sized 66 to $99m^2$.

Improvement of Reverse-time Migration using Homogenization of Acoustic Impedance (음향 임피던스 균질화를 이용한 거꿀시간 참반사보정 성능개선)

  • Lee, Gang Hoon;Pyun, Sukjoon;Park, Yunhui;Cheong, Snons
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.2
    • /
    • pp.76-83
    • /
    • 2016
  • Migration image can be distorted due to reflected waves in the source and receiver wavefields when discontinuities of input velocity model exist in seismic imaging. To remove reflected waves coming from layer interfaces, it is a common practice to smooth the velocity model for migration. If the velocity model is smoothed, however, the subsurface image can be distorted because the velocity changes around interfaces. In this paper, we attempt to minimize the distortion by reducing reflection energy in the source and receiver wavefields through acoustic impedance homogenization. To make acoustic impedance constant, we define fake density model and use it for migration. When the acoustic impedance is constant over all layers, the reflection coefficient at normal incidence becomes zero and the minimized reflection energy results in the improvement of migration result. To verify our algorithm, we implement the reverse-time migration using cell-based finite-difference method. Through numerical examples, we can note that the migration image is improved at the layer interfaces with high velocity contrast, and it shows the marked improvement particularly in the shallow part.

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

Hypertrophic obstructive cardiomyopathy in a Yorkshire Terrier

  • Hwang, Taesung;Park, Junghyun;Jung, Dongin;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.58 no.3
    • /
    • pp.159-162
    • /
    • 2018
  • An 11-year-old, castrated male dog presented with a 3-month history of cough and depression. Auscultation revealed systolic murmur and thoracic radiographs showing enlargement of both the atrium and left ventricle. Echocardiography showed thickened mitral valve and moderate-to-severe left atrial enlargement. Additionally, M-mode echocardiography showed symmetric left ventricular wall thickening and systolic anterior motion of the mitral valve, while Doppler imaging revealed high velocity turbulent flow through the left ventricular outflow tract. Based on echocardiography, this case was diagnosed with hypertrophic obstructive cardiomyopathy. After 5 months, the dog was clinically static in radiography and echocardiography.

Neurogenic muscle hypertrophy: a case report

  • Shin, Hyun Ho;Jeon, Young Hoon;Jang, Seung Won;Kim, Sae Young
    • The Korean Journal of Pain
    • /
    • v.29 no.4
    • /
    • pp.270-273
    • /
    • 2016
  • Muscular hypertrophy is caused mainly due to myopathic disorder. But, it is also rarely produced by neurogenic disorder. A 74-year-old woman complained of right calf pain with hypertrophy for several years. Recent lumbar spine magnetic resonance imaging (MRI) showed central and lateral canal narrowing at the L4-L5 intervertebral space. Lower extremity MRI revealed fatty change of right medial head of the gastrocnemius and soleus, causing right calf hypertrophy. Electrodiagnostic examinations including electromyography and nerve conduction velocity testing demonstrated $5^{th}$ lumbar and $1^{st}$ sacral polyradiculopathy. Integrating all the results, the diagnosis was neurogenic muscle hypertrophy. Neurogenic muscle hypertrophy is very rare, but we recommend that clinicians consider this problem when a patient complains of lower limb hypertrophy and pain.

Visualization of Elastic Waves Propagating on a Solid Surface with Fatigue Cracks by Laser Ultrasonic Technology

  • Imade, Masaaki;Miyauchi, Hidekazu;Okada, Saburo;Yamamoto, Shigeyuki;Takatsubo, Jyunji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.109.4-109
    • /
    • 2001
  • We have developed a laser ultrasonic system for visualization of elastic waves propagating on a solid surface, in order to visualize ultrasonic waves propagating on opaque media. This system can produce a series of successive images as an animation of wave propagation, because of scanning an optical heterodyne probe to measure surface transient displacements. Using this visualization technique, we observed the scattering and diffraction of ultrasonic waves around various shapes of artificial defects, and examined its application to nondestructive inspection. This imaging system provides various kinds of visualization images such as propagation image, amplitude image, arrival time image and velocity image. We have been confident that this technique is available for nondestructive inspection and materials ...

  • PDF

Performance Tests of the Frozen Air Flows in a Refrigerator using PIV/POD Technique (PIV/POD 기법을 이용한 냉장고 냉기류 성능평가)

  • Kim, Kyung-Chun;Kim, Seok-Ro;Kim, Jong-Wook
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.97-100
    • /
    • 2007
  • A new evaluation method for the performance tests of the frozen air in a refrigerator using PIV(Particle Imaging Velocimetry) and POD(Proper Orthogonal Decomposition) techniques is introduced. A two-door refrigerator model was tested for the experiments. Actual temperature measurements were carried out for the drawer No.4 in refrigerator. By evaluating the characteristics of the interior flow of the refrigerator, an optimal shape of the drawer could be suggested through the PIV evaluation test. In this research, in order to find influences the turbulent kinetic energy contribution associated with the dynamic structures, we executed a POD analysis using the method of snapshots and the instantaneous fluctuating velocity field.

  • PDF