• Title/Summary/Keyword: Velocity Imaging

Search Result 313, Processing Time 0.023 seconds

Evaluation of the Impact Force on the Single Spray and Overlap Region of Twin Spray in Full Cone Type Swirl Nozzle (Full Cone Type 스월노즐에서 단일분무와 이중분무의 중첩영역에 대한 충격력 평가)

  • Kim, T.H.;Sung,, Y.M.;Jeong, H.C.;Kim, D.J.;Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.16 no.1
    • /
    • pp.27-36
    • /
    • 2011
  • The impact force on the single and overlap region of twin spray was experimentally evaluated using visualization method in full cone type swirl nozzle spray. Visualization of spray was conducted to obtain the spray angle and breakup process. The photography/imaging technique, based on Particle Image Velocimetry (PIV) using high-speed camera, was adopted for the direct observation of droplet motion and axial velocity measurement, respectively. Droplet size was measured by Particle Motion Analyze System (PMAS). The purpose of this study is to provide fundamental information of spray characteristics, such as impact force, for higher etching factor in the practical wet etching system. It was found that the spray angle, axial velocity and impact force were increased with increasing the nozzle pressure while droplet size decreased with increasing the nozzle pressure. Droplet size increased as the distance from nozzle tip was decreased. The impact force of twin spray in the overlap region was about 63.29, 67.02, 52.41% higher than that of single spray at 40, 50 and 60 mm of nozzle pitch, respectively. Also, the nozzle pitch was one of the important factors in the twin spray characteristics.

Bubble size characteristics in the wake of ventilated hydrofoils with two aeration configurations

  • Karn, Ashish;Ellis, Christopher R;Milliren, Christopher;Hong, Jiarong;Scott, David;Arndt, Roger EA;Gulliver, John S
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.73-84
    • /
    • 2015
  • Aerating hydroturbines have recently been proposed as an effective way to mitigate the problem of low dissolved oxygen in the discharge of hydroelectric power plants. The design of such a hydroturbine requires a precise understanding of the dependence of the generated bubble size distribution upon the operating conditions (viz. liquid velocity, air ventilation rate, hydrofoil configuration, etc.) and the consequent rise in dissolved oxygen in the downstream water. The purpose of the current research is to investigate the effect of location of air injection on the resulting bubble size distribution, thus leading to a quantitative analysis of aeration statistics and capabilities for two turbine blade hydrofoil designs. The two blade designs differed in their location of air injection. Extensive sets of experiments were conducted by varying the liquid velocity, aeration rate and the hydrofoil angle of attack, to characterize the resulting bubble size distribution. Using a shadow imaging technique to capture the bubble images in the wake and an in-house developed image analysis algorithm, it was found that the hydrofoil with leading edge ventilation produced smaller size bubbles as compared to the hydrofoil being ventilated at the trailing edge.

Case Study on the Seismic Refraction Survey in a Subsidence Area (지반침하지역에서의 탄성파 굴절법 탐사 적용사례)

  • Yun, Sang-Ho;Ji, Jun;Lee, Doo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.577-584
    • /
    • 2000
  • Seismic refraction survey was peformed for 10 lines along NE-SW and NW-SE directions above Nampoong gallery at Makyo-ri, Dogye, Samcheok, Kangwon-do. 48 geophones were laid in line with the interval of 1m, and a 5Kg hammer was used as a source at 5 points for each line. Data processing was done using reciprocal time method, GRM, and traveltime tomography which utilizes wavefront expansion method for forward process and SIRT for inversion. The result shows that the first layer has its lower boundary between 3.49m and 8.88m. The P-wave velocity of the first and the second layer were estimated as 270 360m/s and 1550 1940m/s respectively. When the boundary of the first and second layer is smooth enough and the velocity difference is large enough, GRM has little advantage over reciprocal time method. The result of reciprocal method and traveltime tomography shows consistency. The northeast part of the boundary has syncline structure, which is similar to the topography above. This implies that the collapse of the cavities of Nampoong gallery result in the subsidence of the ground surface. The subsidence is in progress across the Youngdong railroad, therefore a proper reinforcement work is required.

  • PDF

Flow Visualization of Pulsatile Flow in a Branching Tube using the PIV System and Numerical Analysis (PIV와 수치해석을 이용한 분지관내 맥동유동의 가시화)

  • Roh, Hyung-Woon;Suh, Sang-Ho;Yoo, Sang-Sin
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.535-540
    • /
    • 2000
  • The objective of the present study is to visualize the pulsatile flow fields by using three-dimensional computer simulation and the PIV system. A closed flow loop system was built for the steady and unsteady experiments. The Harvard pulsatile pump was used to generate the pulsatile pressure and velocity waveforms. Conifer powder as the tracing particles was added to water to visualize the flow field. Two consecutive particle images were captured by a CCD camera for the image processing. The cross-correlation method in combination with the moving searching area algorithm was applied for the image processing of the flow visualization. The pulsatile flow fields were visualized effectively by the PIV system in conjunction with the applied algorithm. The range validation and the area interpolation methods were used to obtain the final velocity vectors with high accuracy. The finite volume predictions were used to analyze three-dimensional flow patterns in the bifurcation model. The results of the PIV experiment and the computer simulation are in good agreement and the results show the recirculation zones and formation of the paired secondary flow distal to the apex of the bifurcated model. The results also show that the branch flow is pushed strongly to the inner wall due to the inertial force effect and helical motions are generated as the flow proceeds toward the outer wall.

  • PDF

Near-infrared studies of iron knots in Cassiopeia A supernova remnant: I. Spectral classification using principal component analysis

  • Lee, Yong-Hyun;Koo, Bon-Chul;Moon, Dae-Sik;Burton, Michael G.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.49.1-49.1
    • /
    • 2013
  • We have been carrying out near-infrared (NIR) spectroscopy as well as [Fe II] narrow band imaging observations of Cassiopeia A supernova remnant (SNR). In this presentation, we describe the spectral classification of the iron knots around the SNR. From eight long-slit spectroscopic observations for the iron-bright shell, we identified a total of 61 iron knots making use of a clump-finding algorithm, and performed principal component analysis in an attempt to spectrally classify the iron knots. Three major components have emerged from the analysis; (1) Iron-rich, (2) Helium-rich, and (3) Sulfur-rich groups. The Helium-rich knots have low radial velocities (${\mid}v_r{\mid}$ < 100 km/s) and radiate strong He I and [Fe II] lines, that match well with Quasi-Stationary Flocculi (QSFs) of circumstellar medium, while the Sulfur-rich knots show strong lines of oxygen burning materials with large radial velocity up to +2000 km/s, which imply that they are supernova ejecta (i.e. Fast-Moving Knots). The Iron-rich knots have intermediate characteristics; large velocity with QSF-like spectra. We suggest that the Iron-rich knots are missing "pure" iron materials ejected from the inner most region of the progenitor and now encountering the reverse shock.

  • PDF

Compact Elliptical Galaxies Hosting Active Galactic Nuclei in Isolated Environments

  • Rey, Soo-Chang;Oh, Kyuseok;Kim, Suk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.69.2-69.2
    • /
    • 2021
  • We present the discovery of rare active galactic nuclei (AGNs) in nearby (z<0.05) compact elliptical galaxies (cEs) located in isolated environments. Using spectroscopic data from the Sloan Digital Sky Survey (SDSS) Data Release 12, four AGNs were identified based on the optical emission-line diagnostic diagram. SDSS optical spectra of AGNs show the presence of distinct narrow-line emissions. Utilizing the black hole (BH) mass-stellar velocity dispersion scaling relation and the correlation between the narrow L([OIII])/L(Hβ) line ratio and the width of the broad Hα emission line, we estimated the BH masses of the cEs to be in the range of 7×105-8×107 solar mass. The observed surface brightness profiles of the cEs were fitted with a double Sérsic function using the Dark Energy Camera Legacy Survey r-band imaging data. Assuming the inner component as the bulge, the K-band bulge luminosity was also estimated from the corresponding Two Micron All Sky Survey images. We found that our cEs follow the observed BH mass-stellar velocity dispersion and BH mass-bulge luminosity scaling relations, albeit there was a large uncertainty in the derived BH mass of one cE. In view of the observational properties of BHs and those of the stellar populations of cEs, we discuss the proposition that cEs in isolated environments are bona fide low-mass early-type galaxies (i.e., a nature origin).

  • PDF

Quantitative Analysis of Enlarged Cervical Lymph Nodes with Ultrasound Elastography

  • Zhang, Jun-Peng;Liu, Hua-Yan;Ning, Chun-Ping;Chong, Jing;Sun, Yong-Mei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7291-7294
    • /
    • 2015
  • Purpsoe: To investigate the diagnostic value of quantitative analysis of a tissue diffusion and virtual touch tissue imaging quantification (VTIQ) technique with acoustic radiation force impulse (ARFI) elastography for assessing enlarged cervical lymph nodes. Materials and Methods: Fifty-six enlarged cervical lymph nodes confirmed by pathologic diagnoses were covered in the study. According to the results of pathologic diagnosis, patients were classified into benign and malignant groups. All the patients were examined by both conventional ultrasonography and elastography. AREA% and shear wave velocity (SWV) in ROI of different groups were calculated and compared using ROC curves. Cut-off points of AREA% and SWV were determined with receiver operating characteristic curves. Results: Final histopathological results revealed 21 cases of benign and 35 cases of malignant lymph nodes. The mean values of AREA% and SWV in benign and malignant groups were $45.0{\pm}17.9%$ and $2.32{\pm}0.57m/s$, and $61.3{\pm}21.29%$ and $4.36{\pm}1.25$)m/s, respectively. For the parameters of elastography, "AREA%" and SWV demonstrated significant differences between groups (p=0.002). AREA% was positively correlated with SWV with a correlation coefficient of 0.809 (P<0.001). Conclusions: Stiffness of different lymph node diseases in patients may differ. Elastography can evaluate changes sensitively and provide valuable information to doctors. The study proved that the VTIQ elastography technique can play an important role in differential diagnosis of lymph nodes.

Carpal Tunnel Syndrome : Correlation between Magnetic Resonance Imaging and Nerve Conduction Study (수근관증후군 : 자기공명영상과신경전도검사의 상관 관계)

  • Park, Seong-Ho;Nam, Hyunwoo;Choi, Won-Joon;Yang, Hee Jin;Chung, Hye Won;Kim, Sam Soo;Lee, Sang Hyung;Lee, Yong-Seok;Song, Chi Sung;Chung, Young Seob;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.2
    • /
    • pp.89-94
    • /
    • 2000
  • Purpose : Carpal tunnel syndrome (CTS) is a disorder of median nerve at wrist. It is usually diagnosed through clinical manifestation and nerve conduction study (NCS). However, sometimes, NCS does not provide a reliable evidence to reach the diagnosis. Thus, authors performed this study to determine whether NCS was correlated with specific parameters measured on magnetic resonance imaging (MRI) which might become a potential complemental diagnostic tool. Methods : We performed MRI in 34 wrists of 18 patients with clinical manifestations of CTS and pathologic nerve conduction values and analyzed them at levels of the distal radioulnar joint, pisiform and hook of hamate, Results : Increase in the cross-sectional area of the median nerve at the pisiform level and flattening, increased signal intensity, and contrast enhancement of the median nerve at levels of the pisiform and hook of hamate were statistically significant. Change in cross sectional areas between the distal radioulnar joint and hamate and the signal intensities at levels of pisiform and hamate were well correlated with the median nerve conduction velocity. Conclusions : Characteristic MRI findings in CTS reported previously were well demonstrated and some of MRI parameters are well correlated with nerve conduction study. MRI, despite cost, may help in evaluating CTS.

  • PDF

Parametric Imaging with Respiratory Motion Correction for Contrast-Enhanced Ultrasonography (조영증강 초음파 진단에서 호흡에 의한 흔들림을 보정한 파라미터 영상 생성 기법)

  • Kim, Ho-Joon;Cho, Yun-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.2
    • /
    • pp.69-76
    • /
    • 2020
  • In this paper, we introduce a method to visualize the contrast diffusion patterns and the dynamic vascular patterns in a contrast-enhanced ultrasound image sequence. We present an imaging technique to visualize parameters such as contrast arrival time, peak intensity time, and contrast decay time in contrast-enhanced ultrasound data. The contrast flow pattern and its velocity are important for characterizing focal liver lesions. We propose a method for representing the contrast diffusion patterns as an image. In the methods, respiratory motion may degrade the accuracy of the parametric images. Therefore, we present a respiratory motion tracking technique that uses dynamic weights and a momentum factor with respect to the respiration cycle. Through the experiment using 72 CEUS data sets, we show that the proposed method makes it possible to overcome the limitation of analysis by the naked eye and improves the reliability of the parametric images by compensating for respiratory motion in contrast-enhanced ultrasonography.

Visual Discomfort Analysis of Binocular Depth Change on 3D Stereoscopic Imaging (입체영상의 양안 깊이 변화에 따른 시청 피로도 분석)

  • Kim, Nam-Gyu
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.127-135
    • /
    • 2015
  • The development of stereoscopic display hardwares and 3D authoring softwares expands its application areas from particular virtual simulation applications to general movies, games, advertising applications. However, the binocular-based 3D stereoscopic images cause fatigue to viewers. Recent performed many research results about the binocular stereoscopy's depth perception and viewers' fatigue are derived from experimental users studies. In some results, watching and making guidelines for 3D stereoscopic imaging contents are introduced. The 3D stereoscopic-related contents have the contradictory aspects, which are audiences' pursuit of a tolerable minimum fatigue and producer's its of excessive depth changes for providing viewers' immersion. This paper provides user experiments and analysis data in aspects of 3D depth changes. For use of producers, a safety zone and translational velocity of 3D depth changes are introduced. Also, on the viewer side, we present the depth change adaptation time by using an EEG device.