• 제목/요약/키워드: Velocity Change

검색결과 1,981건 처리시간 0.035초

함정 기관실내 활동의 순환 및 호흡 기능에 대한 영향 (Changes in Circulatory and Respiratory Activities Observed on Men in an Engine Room of a Navy Ship)

  • 현광철;남기용
    • The Korean Journal of Physiology
    • /
    • 제1권2호
    • /
    • pp.199-213
    • /
    • 1967
  • Circulatory and respiratory activities were observed in men exposed to the environment of engine room of a cruising Republic of Korea Navy ship and compared to the control values obtained in an ordinary laboratory room on land. The environment of an engine room of cruising navy ship was presumed to be a multiple stress acting on men. The environment of the engine room included high temperature $(35-42^{\circ}C)$, low relative humidity (20-38% saturation), vibration (about 7 cycles per second), rolling and pitching of ship and noises. Sixteen men were divided into two groups consisted of each 8 subjects. Subjects of sea duty group had experience of continuous on board duty averaging 3.5 years. Men of land duty group had no experience of on board activity. On land observations were made on one day prior to the boarding and leaving the port and four days after landing. In between observations in the engine room were made on the first, 5 th, 9 th, 12 th, and 14 th day of on board activity. The whole experimental period lasted for 20 days. Measurements on circulatory and respiratory parameters were at standing resting state (after 30 minutes standing in the case of on land study and 15 minutes in engine room study) and within one minute after cessation of on the spot running of which rhythm was 30/min. and lasted for 5 minutes. Oxygen consumption and pulmonary function test were done in the period of two minutes from the 3rd to 5th minutes of running. The following results were obtained. 1. Body temperature showed no change regardless of group difference or on land or on board measurements. 2. Pulse rate increased markedly after boarding the ship id both groups. Pulse rate increased from the first day on board at rest and after exercise as compared to the on land control value. This increase in pulse rate was more marked after exercise. Sea duty group showed less increase in pulse rate at rest than the land duty group. Standing and resting pulse rate of sea duty group on lam was 81 and increased to 87 at the 5th day on board and remained smaller than the land duty group throughout the period on board. Control standing and resting pulse rate of land duty group on land was 76 and reached 89 at the 9th day on board and thereafter decreased a little. Pulse rate of land duty group at rest on board remained greater than that of sea duty group throughout the period on board. 3. Systolic blood pressure of sea duty group increased after boarding the ship and remained higher than the control value on land. In the land duty group, however, systolic blood pressure decreased during the period on board the ship. Diastolic blood pressure decreased in both groups. 4. Resting breathing rate of land duty group increased and remained higher than the control value on land. In sea duty group, however, resting breathing rate showed a transient increase on the 1st day on board and decreased thereafter to the control value on land and kept the same level throughout the period of cruise. Absolute value of breathing rate in the sea duty group was greater than the land duty group both at rest and after exercise. 5. There was a lowering of breathing efficiency in both groups. Thus, increases in tidal volume and minute ventilation volume and decreases in maximum breathing capacity, vital capacity, capacity ratio and air velocity Index were observed after boarding the ship. An increase in ventilation equivalent was also observed in both groups. The lowering of breathing efficiency was more marked in the land duty group than the sea duty group. 6. Energy expediture increased in both groups during their stay on the ship and was more marked in the sea duty group. 7, Lactate concentration in venous blood at rest and after exercise increased after boarding the ship and no group difference was observed.

  • PDF

근접촉쌍성 XZ CMi의 CCD 측광관측과 광도곡선 분석 (CCD Photometric Observations and Light Curve Synthesis of the Near-Contact Binary XZ Canis Minoris)

  • 김천휘;박장호;이재우;정장해;오준영
    • Journal of Astronomy and Space Sciences
    • /
    • 제26권2호
    • /
    • pp.141-156
    • /
    • 2009
  • 근접촉쌍성 XZ CMi의 BV 측광관측을 수행하여 새로운 광도곡선과 총 7개의 극심시각을 획득하였다. 관측한 극심시각과 지금까지 발표된 극심시각을 수집하여 XZ CMi의 궤도 공전주기를 분석한 결과, 이 쌍성계의 공전주기가 지난 70년간 영년 주기감소와 더불어 규칙적으로 변화함을 확인하였다. 규칙적인 변화를 제3천체에 의한 광시간 효과로 가정하여 0.0056일의 진폭, 약 29년의 주기, 그리고 0.71의 궤도이심율의 광시간 궤도를 결정하였다. 관측된 영년 주기감소($-5.26{\times}10^{-11}d/P$)를 자기제동 항성풍의 각운동량 손실에 의한 주기감소($-8.20{\times}10^{-11}d/P$)와 질량이 작은 반성에서 주성으로 질량 이동에 의한 주기 증가($2.94{\times}10^{-11}d/P$)가 동시에 일어나는 것으로 해석하였다. 이런 관점에서 AML에 의한 주기감소율은 질량 이동에 의한 공전주기 증가율보다 그 크기가 약 3배 정도 크며, 반성에서 년간 $3.21{\times}10^{-8}M_{\odot}$의 질량이 주성으로 이동된다. 관측된 BV 광도곡선을 최근의 Wilson & Devinney 쌍성코드로 주성의 온도를 달리하는 두가지 모형(8200K와 7000K)을 상정하여 분석하였다. 두가지 모형 해 모두 XZ CMi가 반성이 로쉬 로브를 채웠으나, 주성은 아직 로쉬 로브를 채우지 않은 근접촉 쌍성임과 약 15-17%의 제3광도가 이 계에 있음을 보여준다. 그러나, 제3광도를 내는 천체가 주기연구에서 제안한 제3천체와 동일 천체가 아닌 것은 확실하다. 두 모형의 $\sum(O-C)^2$의 차이는 너무 미미하여, 현 시점에서 어느 해가 더 관측치를 잘 맞추는 지를 가릴 수는 없었다. 그간 연구자간에 불일치하였던 질량비의 다양성 문제는 아직도 풀리지 않는 숙제로 남아있다. 이를 해결하기 위해서 분광시선속도곡선과 스펙트럼의 관측과 더불어 정밀 측광관측이 필요하다.

가드레일에 차량 충돌 시 성토사면의 거동분석 (Behavior Analysis of Fill Slope by Vehicle Collision on Guardrail)

  • 박현섭;안광국
    • 한국지반환경공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.67-74
    • /
    • 2014
  • 최근 산업의 발달로 증가하는 도로와 이를 이용하는 차량의 증가로 인한 교통사고가 지속적으로 증가하고 있다. 교통사고는 운전자과실, 차량결함, 주행도로상태, 자연환경 등의 다양한 불안정 인자들로 인하여 발생한다. 방호울타리의 한 종류인 가드레일은 교통사고 및 이탈을 방지하여 탑승자의 상해와 차량의 파손을 최소로 줄여 차량을 정상주행 시키는 것을 목적으로 한다. 가드레일은 8 tonf 차량이 $15^{\circ}$로 80 km/h의 속도로 가드레일에 충돌하는 시험으로 가드레일의 안정성을 평가하며, 지반은 상대적으로 지지력이 큰 무한평지에서 평가된다. 하지만 국내의 경우 성토사면에 설치된 가드레일은 보호길어깨에 설치되며, 이로 인해 가드레일의 지지력 저하 및 성능저하로 가드레일의 안정성에 문제가 발생할 가능성이 있다. 이러한 가드레일에 대한 기존 연구는 무한평지에 설치된 가드레일 및 차량의 안정성에 대한 연구가 수행되었다. 하지만 차량 충돌 시 가드레일이 설치된 성토사면의 거동에 대한 연구는 미비한 실정이다. 이에 본 연구에서는 차량 충돌 시 성토사면의 거동을 확인하기 위해 유한요소프로그램인 LS-DYNA를 이용하여 성토사면에 설치된 가드레일의 지주 매입깊이를 변화시켜 수치해석을 수행하였다. 그리고 수치해석은 NCAN(National Crash Analysis Center)에서 제공하는 8 tonf 트럭을 이용하여 성토사면에서 가드레일 지주의 매입깊이를 변화시키면서 충돌 해석을 수행하였다. 그 결과, 가드레일 지주의 매입깊이가 증가함에 따라 성토사면의 변위와 응력이 증가하는 것으로 나타났으며, 450 mm 깊이에서 지반지지력이 저하되는 것으로 나타났다.

과거 문헌 비교를 통한 원주천 수서곤충 군집구조 변화 (Changes in Aquatic Insect Community Structure in Wonju Stream based on a Comparison of Previous Studies)

  • 한중수;최준길;원경호;이황구
    • 환경생물
    • /
    • 제36권3호
    • /
    • pp.400-411
    • /
    • 2018
  • 본 연구는 2015년 5월부터 2016년 9월까지 원주시의 주요 하천인 원주천을 대상으로 조사를 실시하였다. 조사지점은 상류지역인 관설동에서 하류지역인 호저면까지 총 3지점을 선정하였으며, 물리 화학적 분석, 수서곤충상 변화, 군집분석, 기능군 분석, Rarefaction curve, 통계분석 등을 실시하여 2004년의 연구와 비교 분석하였다. 2004년과 2016년의 종비율과 개체수 비율을 비교한 결과, 종비율은 2004년에 19종 (38.78%), 2016년에 22종 (36.67%)으로 하루살이목에서 가장 많은 것으로 분석되었으며, 개체수 비율은 2004년에 27,759.2개체(ind. $m^{-2}$, 84.30%), 2016년에 4,573.2개체(ind. $m^{-2}$, 41.64%)로 파리목에서 가장 높은 것으로 분석되었다. 전체 출현종 변화를 분석한 결과 공통종은 총 26종, 2004년에만 출현한 종은 총 23종, 2016년에만 출현한 종은 총 34종으로 분석되었다. 군집분석 결과, 2004년, 2016년의 우점도지수, 다양도지수, 균등도지수, 풍부도지수는 유의한 차이가 있는 것으로 분석되었다(p<0.05). 전체 우점종은 2004년, 2016년 모두 깔따구류(Cronomidae sp.)로 분석되었으며, 아우점종은 2004년에는 줄날도래 (Hydropsyche kozhantschikovi), 2016년에는 명주 각다귀 KUa (Antocha KUa)로 나타났다. 기능군 분석 결과, 서식기능군은 Burrowers가 평균 -68.00% (${\pm}2.15$)로 가장 큰 변동율을 나타내었으며, 섭식기능군은 Collector-gathers가 평균 -40.12% (${\pm}1.77$)로 가장 큰 변동율을 나타내었다. Rarefaction curve 분석 결과, 연도별 관찰된 개체수를 71개체(ind. $m^{-2}$)로 가정할 때 2004년에 6종, 2016년에 8종으로 중류지역에서 종이 가장 빈약한 것으로 분석되었다. 물리적 요인, 수질, 군집지수, 종수, 개체수의 상관성을 분석한 결과, 물리적 요인 및 수질은 다양도지수, 균등도지수, 개체수와 유의한 상관관계를 나타내는 것으로 분석되었다. MDS 분석 결과, 2004년에는 상 하류지역의 유사도가 높은 것으로 분석되었고 2016년에는 상 하류지역의 유사도가 낮은 것으로 분석되어 물리 화학적 환경변화가 원주천 일대 수서곤충의 종조성에 영향을 미친 것으로 판단된다.

L-arginine 섭취가 고강도 훈련 프로그램에 따른 카누선수의 근 손상 지표, 피로 물질 및 경기력 향상에 미치는 영향 (Effects of l-arginine supplementation with high-intensity training on muscle damage and fatigue index and athletic performance in Canoe Athletes)

  • 정종환;강은범;김창환
    • 한국응용과학기술학회지
    • /
    • 제36권3호
    • /
    • pp.942-953
    • /
    • 2019
  • 본 연구는 L-arginine 섭취가 고강도 훈련 프로그램에 따른 카누선수의 근 손상 지표, 피로 물질 및 경기력 향상에 미치는 영향을 확인하는데 목적이 있다. 이를 위해 고등학교 카누 선수 7명을 대상으로 고강도 훈련 프로그램을 적용하였으며, 고강도 훈련 프로그램은 주 2회의 유산소 운동(화, 목), 주 3회의 무산소 운동(월, 수, 금) 그리고 주 5회의 유연성 운동을 실시하였다. 고강도 훈련 프로그램을 진행하는 6주 과정 중에 처음 2주는 약물섭취(L-arginine or 위약)를 실시하고 다음 2주는 wash out, 그리고 마지막 2주도 약물섭취(L-arginine or 위약)를 실시하였다. 모든 연구대상자들이 L-arginine 섭취(시험군)와 위약그룹(대조군)으로 배정되는 교차설계로 디자인하였다. L-arginine은 하루 총 3g으로 섭취하였다. 채혈을 통해 L-arginine 섭취에 따른 근 손상 지표, 피로 지표, 항산화력을 확인하였으며, 혈관내피세포기능 분석을 위해 FMD, 그리고 카누 에르고미터를 활용하여 카누 경기력을 분석하였다. 본 연구결과 L-arginine 섭취에 따른 Ammonia, IP, CK의 수준의 직접적인 효과는 나타나지 않았으며, LDH의 수준은 L-arginine 섭취로 인해 PLA 그룹보다 ARG 그룹에서 더 감소하는 것으로 나타났다. L-arginine 섭취에 따른 Total NO, d-ROMs, BAP, 그리고 FMD의 수준도 통계적으로 유의한 차이는 없는 것으로 나타났다. 마지막으로 카누 경기력 향상을 확인하기 위해 실시한 500M 카누 에르고미터 결과에서 총시간, 스트록 거리, 평균속도 분석에서 L-arginine의 운동수행능력 향상의 직접적인 효과는 나타나지 않았다. 하지만 L-arginine 섭취로 인해 근 손상 지표, 피로 지표, 항산화력, FMD, 그리고 카누 경기력 수준이 개선되는 경향은 나타났다. 따라서 L-arginine 섭취의 잠재적인 운동능력 향상 보조제 효과에 대한 추가적인 연구가 필요할 것으로 생각된다.

동해 독도 냉수성 소용돌이의 이동 특성 (Migration of the Dokdo Cold Eddy in the East Sea)

  • 김재민;최병주;이상호;변도성;강분순
    • 한국해양학회지:바다
    • /
    • 제24권2호
    • /
    • pp.351-373
    • /
    • 2019
  • 인공위성이 관측한 해수면 높이 자료를 활용하여 울릉분지 일대에서 발생하는 냉수성 소용돌이들을 1993년부터 2015년까지 Winding-Angle 방법을 이용하여 탐지하고 분류하였다. 냉수성 소용돌이들 중에서 동한난류 사행의 첫 번째 골에서 형성되어 동쪽으로 흐르는 해류의 주경로로부터 남서쪽으로 떨어져 나온 독도 냉수성 소용돌이(Dokdo Cold Eddy, DCE)를 구분하였고, 그 이동 특성을 분석하였다. 또한 국립수산과학원(National Institute of Fisheries Science)이 관측한 수온과 염분 자료와 Hybrid Coordinate Ocean Model의 수치모의 결과를 이용하여 DCE 중심 근처에서 수온과 유속의 수직구조를 살펴보았다. DCE는 23년 동안 총 112개 발생하였고, 이 중 39개의 DCE가 서쪽으로 이동하여 한국 동해안 근처 연안에 도달하였으며, 평균 이동 거리는 250.9 km, 평균 수명은 93일, 평균 이동 속도는 3.5 cm/s였다. 나머지 73개의 DCE는 동쪽으로 이동하거나 생성된 위치 주변을 맴돌다가 소멸하였다. DCE 아래 50~100 m에서 수온(T)과 염분(S)이 주변보다 낮아(T < $5^{\circ}C$, S < 34.1) 등온선들과 등염선들이 돔(dome, 반구형으로 된 지붕 모양) 구조를 보였다. 또한 DCE의 중심에서 평균 38 km 떨어진 곳에서 10 cm/s 이상의 해류가 표층부터 수심 300 m까지 반시계방향으로 원을 그리며 흐른다. 동한난류가 이안하여 동쪽으로 흐르다가 울릉도 북쪽에서 울릉도를 끼고 시계방향으로 흘러서 사행을 시작하고, 울릉도 동쪽에 위치한 사행의 첫 번째 골이 남서쪽으로 깊이 파고들면, 해류사행의 마루와 마루가 연결되고 골 부분이 독립적으로 떨어져 나와 반시계방향 순환을 형성하면서 DCE가 생성된다. DCE가 서쪽으로 이동할 때 울릉 난수성 소용돌이(Ulleung Warm Eddy, UWE)의 가장자리를 따라 우회하여 시계방향으로 U 모양을 그리며 한국 동해안 쪽으로 이동한다. DCE가 연안 부근에 도달하면, 동한난류는 냉수성 소용돌이 보다 더 남쪽에서 이안하고, 냉수성 소용돌이의 가장자리를 따라 우회하여 북쪽으로 흐른다. 연안에서 독도 냉수성 소용돌이가 약화되고 약 30일 후에 소멸하면, 동한난류가 다시 한국 동해안을 따라 북쪽으로 흘러서 본래의 경로를 회복한다. DCE는 열과 염을 북쪽에서 남쪽으로 꾸준히 수송하고 울릉분지 남서쪽에 냉수해역 형성에 도움을 주며, 양의 상대와도를 가지고 와서 동한난류의 경로를 변경시키는 역할을 한다. 서쪽으로 이동하는 DCE 중에서 일부는 연안 냉수성 소용돌이와 병합되어 울릉분지 서쪽에 넓고 긴 냉수해역을 만들고 반시계 방향의 순환을 형성한다. 이와 같이 병합된 소용돌이는 북쪽에 UWE를 남쪽에 동한난류로부터 분리시킨다.

Positron Annihilation Spectroscopy of Active Galactic Nuclei

  • Doikov, Dmytry N.;Yushchenko, Alexander V.;Jeong, Yeuncheol
    • Journal of Astronomy and Space Sciences
    • /
    • 제36권1호
    • /
    • pp.21-33
    • /
    • 2019
  • This paper focuses on the interpretation of radiation fluxes from active galactic nuclei. The advantage of positron annihilation spectroscopy over other methods of spectral diagnostics of active galactic nuclei (therefore AGN) is demonstrated. A relationship between regular and random components in both bolometric and spectral composition of fluxes of quanta and particles generated in AGN is found. We consider their diffuse component separately and also detect radiative feedback after the passage of high-velocity cosmic rays and hard quanta through gas-and-dust aggregates surrounding massive black holes in AGN. The motion of relativistic positrons and electrons in such complex systems produces secondary radiation throughout the whole investigated region of active galactic nuclei in form of cylinder with radius R= 400-1000 pc and height H=200-400 pc, thus causing their visible luminescence across all spectral bands. We obtain radiation and electron energy distribution functions depending on the spatial distribution of the investigated bulk of matter in AGN. Radiation luminescence of the non-central part of AGN is a response to the effects of particles and quanta falling from its center created by atoms, molecules and dust of its diffuse component. The cross-sections for the single-photon annihilation of positrons of different energies with atoms in these active galactic nuclei are determined. For the first time we use the data on the change in chemical composition due to spallation reactions induced by high-energy particles. We establish or define more accurately how the energies of the incident positron, emitted ${\gamma}-quantum$ and recoiling nucleus correlate with the atomic number and weight of the target nucleus. For light elements, we provide detailed tables of all indicated parameters. A new criterion is proposed, based on the use of the ratio of the fluxes of ${\gamma}-quanta$ formed in one- and two-photon annihilation of positrons in a diffuse medium. It is concluded that, as is the case in young supernova remnants, the two-photon annihilation tends to occur in solid-state grains as a result of active loss of kinetic energy of positrons due to ionisation down to thermal energy of free electrons. The single-photon annihilation of positrons manifests itself in the gas component of active galactic nuclei. Such annihilation occurs as interaction between positrons and K-shell electrons; hence, it is suitable for identification of the chemical state of substances comprising the gas component of the investigated media. Specific physical media producing high fluxes of positrons are discussed; it allowed a significant reduction in the number of reaction channels generating positrons. We estimate the brightness distribution in the ${\gamma}-ray$ spectra of the gas-and-dust media through which positron fluxes travel with the energy range similar to that recorded by the Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) research module. Based on the results of our calculations, we analyse the reasons for such a high power of positrons to penetrate through gas-and-dust aggregates. The energy loss of positrons by ionisation is compared to the production of secondary positrons by high-energy cosmic rays in order to determine the depth of their penetration into gas-and-dust aggregations clustered in active galactic nuclei. The relationship between the energy of ${\gamma}-quanta$ emitted upon the single-photon annihilation and the energy of incident electrons is established. The obtained cross sections for positron interactions with bound electrons of the diffuse component of the non-central, peripheral AGN regions allowed us to obtain new spectroscopic characteristics of the atoms involved in single-photon annihilation.

포항시 신광면 및 흥해읍 일대 지하수의 배경수질 연구 (Natural Baseline Groundwater Quality in Shingwang-myeon and Heunghae-eup, Pohang, Korea)

  • 이현아;이현주;권은혜;박종훈;우남칠
    • 지질공학
    • /
    • 제30권4호
    • /
    • pp.469-483
    • /
    • 2020
  • 지하수의 장기적인 수위 및 수질 관측 결과는 기후변화를 비롯한 다양한 재해의 영향 평가 및 대응 수립에 있어 중요한 자료로 활용될 수 있을 뿐 아니라 지진과 같은 지질학적 재난의 예측과 관리에도 기초적인 자료로 활용될 수 있다. 그러나 장기적인 모니터링을 통해 지진 예측과 지진으로 인한 지하수위와 수질 변동 사례를 평가한 국외와 달리 국내에서는 용존 이온의 변화와 같은 지진 전후 관측된 개별 수질 요소의 변화와 관련한 보고 사례가 적다. 이 연구에서는 지하수 수질 이상 변동의 기준을 설정하기 위해 포항시 신광면과 흥해읍에 존재하는 14개 농업용 관정에서 2018년 7월부터 5회에 걸쳐 지하수를 채취하여 분석하였다. 분석 결과, 신광면에서는 Ca2+가, 흥해읍에서는 Na+가 우세한 것으로 나타났다. 농업 활동의 영향으로 보이는 NO3-의 우세가 신광면 지하수에서 나타났으며, 흥해읍의 한 관정에서는 음용수 기준을 100배 가까이 초과하는 높은 농도의 Fe가 검출되었다. 기반암과 퇴적 특징 차이에서 수반된 유속 차이와 물-암석 반응의 결과로 신광면에 비해 흥해읍의 지하수에서 상대적으로 높은 용존 이온 농도가 관측되었다. 물-암석 상호 반응을 고려할 때, 신광면의 지하수는 대부분 화강암과 규산염 풍화작용의 영향을, 흥해읍은 주로 규산염과 탄산염 풍화작용의 영향을 받았을 것으로 판단된다. 본 연구를 통해 신광면과 흥해읍의 지하수 배경 농도를 파악하였으며, 계절적으로 변이가 큰 관정에 대해서는 지속적인 모니터링을 수행할 필요가 있을 것으로 보인다.

시뮬레이션 모형에 의한 온실의 열환경 분석 (Analysis of Greenhouse Thermal Environment by Model Simulation)

  • 서원명;윤용철
    • 생물환경조절학회지
    • /
    • 제5권2호
    • /
    • pp.215-235
    • /
    • 1996
  • 본 연구에서 수행한 Model 시뮬레이션에 의한 열환경 분석 기법은 지역별로 다양한 기상여건 하에서 대상온실의 난방 및 냉방부하를 보다 합리적으로 예측할 수 있을 뿐만 아니라 냉방이나 난방용 시스템의 결정을 비롯한 난방대책을 수립하고, 에너지 이용 전략의 수립이나 계절적인 작부계획 수립, 온실산업용 적지선정 등에 유익하게 활용될 수 있을 것이라 판단된다. 본 연구에서는 온실의 적극적인 환경조절 유형을 난방과 냉방의 두 가지로 대별하고, 난방 소요열량 산정을 비롯하여 야간의 보온 커튼효과, Heating Degree-Hour 산정 등 난방과 관련된 시뮬레이션은 동적 모형을 이용하여 시간별, 일별 및 월별로 검토하였으며, 환기를 비롯한 차광, 증발냉각시스템의 효과 분석은 정적모형을 이용하여 검토하였다. 특히 하절기 지하수와 같은 저온수를 직접 이용하거나 Heat Pump를 통하여 확보될 수 있는 저온수를 이용하여 온실의 피복면에 살수함으로서 확보할 수 있는 온실냉방효과를 검토하는 데는 1.2m$\times$2.4m 크기의 모형온실을 제작하여 기초실험을 수행함으로서 동절기의 수막시스템의 보온효과와 마찬가지로 하절기 냉방 효과를 거둘 수 있다는 가능성을 확인하였다. 본 연구에 활용된 온실의 수치 환경모형 중 난방관련 시뮬레이션용 동적 수치모형은 소기의 목적을 달성하는데 충분히 응용될 수 있는 이론모형이다. 이 이론모형이 범용성이 높은 것은 온실 내ㆍ외의 미기상 변화, 특히 난방이나 냉방이 본격적으로 요구되는 기간동안에 온도, 습도, 일사, 풍속 등의 미기상 인자들을 면밀하게 관찰하여 실측된 자료를 바탕으로 개발되었고, 다양한 자료에 의해 충분히 검정되었기 때문이다. 본 연구에서는 경남 진주지역의 어느 특정 기간(1987년)의 시간별 기상자료를 중심으로 온실의 열적 환경변화에 대한 수치모형 시뮬레이션을 실시하였으며, 아직 수치모형에 의한 시뮬레이션이 불가능한 일부 냉방효과를 검토하는 데는 모형 실험을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1. 주간과 야간의 설정온도를 달리하고 다단계 변온조절방식으로 시뮬레이션을 행한 결과 난방 소요열량은 난방 설정온도에 따라 현저한 차이를 보였다. 특히 주간 설정온도에 비하여 야간 설정온도가 난방 소요열량에 예민하게 영향을 미치므로 야간의 설정온도 결정에 신중을 기해야 할 것으로 판단된다. 2. 기존의 Heating Degree-Hour 자료는 평균 외기온을 중심으로 임의의 설정온도에 대하여 산정된 값이므로 난방 소요열량에 대한 상대적인 비교수단은 되나 고려되는 기상인자의 제한과 설정온도의 임의성 때문에 실용성이 부족하다. 따라서 본 연구에서 제시된 것처럼 온실 주변의 제반 미기상 인자나 경계조건이 반영됨은 물론 작물의 생육상태 및 구체적인 설정온도까지도 고려하는 동적 수치모형으로 시시각각으로 예측된 실내기온을 중심으로 재배기간 동안의 난방열량을 적산함이 합리적이라 판단된다. 기존의 MDH 자료로 난방 설계를 할 경우에는 지나치게 과잉설계 될 가능성이 있다. 3. 산정된 난방 소요열량은 물론 커튼의 보온성능도 월별 기상여건에 따라 현저한 차이를 보이며, 시뮬레이션에 이용된 커튼의 경우 높은 보온효과를 보임으로서 년 평균 50% 이상의 난방 에너지를 절감할 수 있으며, 동절기 3-4개월의 집중 난방기에 에너지가 크게 절감됨을 발견할 수 있다. 4. 고온기 환기성능은 온실의 구조, 기상조건, 작물의 생육상태 등에 따라 다소의 차이가 있으나 환기율에 의해 크게 좌우되며, 시뮬레이션에 이용된 두 가지 농가보급형 온실 모두 환기율의 증가에 따른 실내기온의 강하 효과가 환기율이 1회/min 정도를 넘어서면서 급격히 둔화되는 현상을 보인다. 이는 기존에 권장되고 있는 적정 환기율인 1회/min 전후의 환기 시스템을 갖추는 것이 합리적임을 확인해 준다. 5. 작물이 성숙된 유리온실에서 외기의 상대습도가 50%인 쾌청한 주간동안 연속적으로 1회/min로 환기를 시킬 경우 실내기온 36.5$^{\circ}C$의 대조구에 비한 온도강하는 50% 차광만 했을 시 2.6$^{\circ}C$이고 효율 80%의 Pad & Fan 시스템만 작동시 6.1$^{\circ}C$ 정도이며, 차광과 냉각시스템을 동시에 작동시는 약 8.6$^{\circ}C$로서 외기온보다 3.3$^{\circ}C$가 낮은 28$^{\circ}C$까지 실내온도를 낮출 수 있으나, 동일 조건하에서 외기의 상대습도가 80%로 높은 경우에는 Pad & Fan시스템에 의한 온도강하가 2.4$^{\circ}C$에 불과하여 50% 차광하에서도 외기온 이하로 실내온도를 낮출 수 없음을 알 수 있다. 6. 하절기 3개월(6/1-8/31)동안 Pad & Fan 시스템의 냉방효과($\Delta$T)는 설정된 작동 온도에 따라 다소 차이를 보일 것으로 예상되나 본 시뮬레이션에서 설정한 시스템의 작동 온도 27$^{\circ}C$에서 상대습도와의 상관관계는 대략 다음과 같았다: $\Delta$T= -0.077RH+7.7 7. 전형적인 하절기 주간기상 하에서 경시적 냉방효과를 분석한 결과 환기만으로는 실내기온을 외기온 보다 5$^{\circ}C$ 높게 유지하는 정도가 고작이고, 차광이나 증발식 냉방시스템 만으로는 작물이 성숙한 단계에서조차도 외기온 이하로 떨어뜨리기가 어려우나 차광과 아울러 증발식 냉방을 병행할 경우에는 작물상태에 따라 다소 차이는 있지만 실내기온을 외기온보다 2.0-2.3$^{\circ}C$ 낮게 유지할 수 있음을 발견할 수 있다. 8. 일사가 차단된 27.5-28.5$^{\circ}C$의 외기온하에서 6.5-8.5$^{\circ}C$의 냉수를 온실 바닥면적 1$m^2$당 1.3 liter/min의 유량으로 온실표면에 살수했을 때 실내기온을 외기온보다 1$0^{\circ}C$ 낮은 16.5-18.$0^{\circ}C$ 정도로 낮출 수 있었다. 앞으로 살수 수온(T$_{w}$ )이나 외기온(T$_{o}$ ) 뿐만아니라 살수율(Q)에 따라 온실기온 (T$_{g}$ )에 미치는 상관 관계 T$_{g}$ = f(T$_{w}$ , Q, T$_{o}$ )를 구명하여 지하수 자체 또는 Heat Pump를 이용한 지하수온 이하의 냉수로 온실냉방의 가능성을 구명하는 것이 앞으로의 과제이다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF