• 제목/요약/키워드: Variation type

검색결과 3,351건 처리시간 0.031초

Gait Type Classification Using Pressure Sensor of Smart Insole

  • Seo, Woo-Duk;Lee, Sung-Sin;Shin, Won-Yong;Choi, Sang-Il
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권2호
    • /
    • pp.17-26
    • /
    • 2018
  • In this paper, we propose a gait type classification method based on pressure sensor which reflects various terrain and velocity variations. In order to obtain stable gait classification performance, we divide the whole gait data into several steps by detecting the swing phase, and normalize each step. Then, we extract robust features for both topographic variation and speed variation by using the Null-LDA(Null-Space Linear Discriminant Analysis) method. The experimental results show that the proposed method gives a good performance of gait type classification even though there is a change in the gait velocity and the terrain.

의료급여 1종 노인 수급권자의 입원이용 (Hospital Services Utilization in Type-I Medicaid Elderly Beneficiaries)

  • 임승주
    • 동서간호학연구지
    • /
    • 제15권2호
    • /
    • pp.63-70
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate hospital service utilization by the types of hospitals in Type I Medicaid claims frequently cited by elderly beneficiaries. Methods: Three frequently claimed inpatient diseases were selected: cerebral infarction, hypertension and diabetes mellitus. Relevant data were collected for the year 2008 from the computer database of the National Health Insurance Corporation. The data was analyzed using SPSS by descriptive statistics, ANOVA and coefficient of variation. Results: The coefficient of variance of hospitalization per episode was higher than daily hospital expenditure among hospitals for all three diseases. The coefficient of variance of hospitalization per episode was highest for cerebral infarction. The coefficient of variation of hospital expenditure per hospital day was highest for hypertension. Conclusions: Evaluating of the volume and pattern of hospital service utilization and the appropriateness for hospital admission for Type-I Medicaid elderly beneficiaries is important for Medicaid-based case management.

흉복부 방사선 치료 시 압력 기반 복부압박장치 적용에 따른 치료 간 재현성 평가 (Reproducibility evaluation of the use of pressure conserving abdominal compressor in lung and liver volumetric modulated arc therapy)

  • 박가연;김주호;신현경;김민수
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.71-78
    • /
    • 2021
  • 목 적: 폐암과 간암 환자에 대해 압력 기반 복부압박장치를 적용하여 입체적 세기변조 회전 방사선치료(VMAT)를 시행하였을 때의 치료 간(interfraction) 위치 재현성과 호흡 재현성을 평가함으로써 그 유용성을 평가하고자 한다. 대상 및 방법: 압력 기반 복부압박장치를 사용해 입체적 세기변조 회전 방사선치료를 받은 6명의 폐암 환자와 3명의 간암 환자를 대상으로 하였다. 치료 간 위치 재현성 평가를 위해 모의치료 CT 영상과 매일 획득한 CBCT 영상 174건을 비교하여 이미지 정합의 이동 값을 비교, 분석하였다. 치료 간 호흡 재현성 평가를 위해 모의치료 4DCT 영상과 매주 획득한 4D CBCT 영상 54건을 비교하여 호흡량 오차를 구하였다. 결 과: 수평수직 세 방향의 3D 벡터값인 전체 위치변화(Overall position variation, Overall VP)값은 폐와 간에서 각각 평균 1.1 ± 1.4 mm, 4.5 ± 2.8 mm로 나타났다. 호흡 변화(respiratory variation, Vr)값은 폐에서 평균 0.7 mm ± 3.4 mm (p=0.195), 간에서 평균 3.6 mm ± 2.6 mm (p<0.05)로 나타났다. 결 론: 흉복부 방사선 치료 시 압력 기반 복부압박장치의 적용은 복부 압박 재현을 통해 치료 간 종양의 호흡 변이뿐만 아니라 위치 변이를 안정적으로 조절하는 데에 유용한 것으로 사료된다. 보다 안정적인 재현성을 위해 치료 계획 시 적절한 PTV 여유가 고려되어야 하고, 매 치료 전 영상 유도에 따른 표적의 위치와 호흡 검증이 필요하다.

Surgical implications of anatomical variation in anterolateral thigh flaps for the reconstruction of oral and maxillofacial soft tissue defects: focus on perforators and pedicles

  • Kim, Ji-Wan;Kim, Dong-Young;Ahn, Kang-Min;Lee, Jee-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권5호
    • /
    • pp.265-270
    • /
    • 2016
  • Objectives: To gain information on anatomical variation in anterolateral thigh (ALT) flaps in a series of clinical cases, with special focus on perforators and pedicles, for potential use in reconstruction of oral and maxillofacial soft tissue defects. Materials and Methods: Eight patients who underwent microvascular reconstructive surgery with ALT free flaps after ablative surgery for oral cancer were included. The number of perforators included in cutaneous flaps, location of perforators (septocutaneous or musculocutaneous), and the course of vascular pedicles were intraoperatively investigated. Results: Four cases with a single perforator and four cases with multiple perforators were included in the ALT flap designed along the line from anterior superior iliac spine to patella. Three cases had perforators running the septum between the vastus lateralis and rectus femoris muscle (septocutaneous type), and five cases had perforators running in the vastus lateralis muscle (musculocutaneous type). Regarding the course of vascular pedicles, five cases were derived from the descending branch of the lateral circumflex femoral artery (type I), and three cases were from the transverse branch (type II). Conclusion: Anatomical variation affecting the distribution of perforators and the course of pedicles might prevent use of an ALT free flap in various reconstruction cases. However, these issues can be overcome with an understanding of anatomical variation and meticulous surgical dissection. ALT free flaps are considered reliable options for reconstruction of soft tissue defects of the oral and maxillofacial area.

Variation for Morphological Characters in Cultivated and Weedy Types of Perilla frutescens Britt. Germplasm

  • Luitel, Binod Prasad;Ko, Ho-Cheol;Hur, On-Sook;Rhee, Ju-Hee;Baek, Hyung-Jin;Ryu, Kyoung-Yul;Sung, Jung-Sook
    • 한국자원식물학회지
    • /
    • 제30권3호
    • /
    • pp.298-310
    • /
    • 2017
  • Morphological variation between cultivated and weedy types of Perilla frutescens var. frutescens and P. frutescens var. crispa were studied in 327 germplasm by examining 17 morphological characters. The germplasm between the two varieties were varied for their qualitative and quantitative characters. The seed coat color of cultivated P. frutescens var. frutescens is commonly light brown and brown while deep brown color was observed in the weedy type P. frutescens var. frutescens and P. frutescens var. crispa. The leaf size, cluster length, plant height, flower number per cluster and seed weight in cultivated P. frutescens var. frutescens were significantly (P<0.05) different from weedy type P. frutescens var. frutescens and P. frutescens var. crispa. The cultivated P. frutescens var. frutescens exhibited significantly higher plant height (158.6 cm) compared to the weedy P. frutescens var. crispa (133.8 cm). Likewise, seed weight was significantly higher in cultivated (1.9 g) than in the weedy type of P. frutescens var. frutescens (1.6 g) and P. frutescens var. crispa (1.4 g). Principal component analysis (PCA) result showed that the first and second principal component cumulatively explained 86.6% of the total variation. The cultivated type P. frutescens var. frutescens and its weedy accessions were not clearly separated with P. frutescens var. crispa by PCA. Hence it requires the use of molecular markers for better understanding of their genetic diversity.

한국산(韓國産) 주요(主要) 산공재(散孔材)의 도관요소(導管要素) 형태변이(形態變異) (Morphological Variation of Vessel Elements in the Korean Diffuse-porous Woods)

  • 박병대;박상진
    • Journal of the Korean Wood Science and Technology
    • /
    • 제15권3호
    • /
    • pp.1-13
    • /
    • 1987
  • This study was carried out to investigate the variations of dimension and exterior shape of vessel elements, morphology of spiral thickening and ray-vessel pit in korean diffuse-porous woods (56 species, 18 families), The tangential pore diameter and vessel element length was increased, whereas the pore number per unit area($1mm^2$) was decreased from pith outwards. The tangential pore diameter was decreased but the length of vessel element was not changed from earlywood to latewood within an annual ring. However, the dimensional variations of vessel element was not able to be recognized among relative positions in peripheral variation. The exterior shape of vessel element could be classified into four types; Type 1 is without tail, Type 2 with ligulate tail, Type 3 with broad taper tail and Type 4 with the very short length between perforations. The distribution frequency of Type 2 and 3 was relatively high in comparision with the others. According to the prominence, distribution position and branched shape, the spiral thickenings could be divided into five types. The spiral thickenings occurred 52% in the species observed. Thus it was doubtful to consider the simple presence of spiral thickening as diagnostic index in diffuse-porous woods. The morphology of ray-vessel pit could be grouped as reticulate, scalariform, oval, linear and coalescent type. Most of species examined showed oval and linear type.

  • PDF

高電壓 nozzle 형 오존발생기에 관한 연구 (A study on the high voltage nozzle type ozonizer)

  • 송현직;이광식;이동인;조환
    • 대한전기학회논문지
    • /
    • 제44권1호
    • /
    • pp.97-103
    • /
    • 1995
  • This paper reports the following two topics : $\circled1$ ozone concentration (O$\sub$3con/) and discharge characteristics in flowing O$\sub$2/ with variation of Re$\sub$3/ at high voltage nozzle (HVN) of HVN 10 type ozonizer. $\circled2$ O$\sub$3con/ with variation of Re$\sub$3/ at HVN of HVN 25 type ozonizer. The important conclusions obtained from this paper are as follows. 1) In HVN 10 type ozonizer : $\circled1$ The discharge pattern can be controlled by adjustment of the Re$\sub$3/. $\circled2$ V$\sub$c/ is inversely proportional to pulse width (P$\sub$w/) and pulse frequency (P$\sub$f) $\circled3$ O$\sub$3con/ increase as decreasing of Re$\sub$3/ for constant P$\sub$w/ and P$\sub$f/. $\circled4$ O$\sub$3con/ increase as decreasing of P$\sub$w/, O$\sub$3con/ is proportional to P$\sub$f/. 2) In HVN 25 type ozonizer : O$\sub$3con/ of HVN 25 type ozonizer can increase than that of HVN 10 type ozonizer, according to parallel circuit of applied voltage and serial of supplied gas. As a result, we can obtain O$\sub$3con/ of 825[ppm] as the maximun value.

블리딩저감형 AE감수제를 사용한 콘크리트의 공학적 특성 (Engineering Properties of Bleeding Reduction of Concrete Using AE Water Reducing Agent for the Type of Bleeding Reduction)

  • 한천구;황인성;이승훈;김규동
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.133-140
    • /
    • 2004
  • This study is intended to investigate the properties of bleeding reduction of concrete using AE water reducing agent for the type of bleeding reduction with the replacement admixture. According to the results, when the adding ratio of AE water reducing agent for the type of bleeding reduction increases, a range of normal fluidity and aimed air content are satisfied, setting time is faster than that of normal AE water reducing agent. And bleeding amount decreases, bleeding speed is highest between 60 and 90 min, and sinking depth increases drastically in 50 min. When AE oater reducing agent for the type of bleeding reduction is added, compressive strength shows a slight variation by air content, but there is not a large influence by addition of AE water reducing agent for the type of bleeding reduction. Synthetically, it proves that AE water reducing agent for the type of bleeding reduction satisfies aimed air content in the range of normal slump and can reduce only bleeding without quality variation of compressive strength.

배양조건에 따른 Rotifer (Brachionus plicatilis)의 성장과 크기변화 (Growht and Size Variation of (Brachionus plicatilis) Reared at Different Conditions)

  • 김현준;김정대;최유길;우영배
    • 한국양식학회지
    • /
    • 제10권2호
    • /
    • pp.219-225
    • /
    • 1997
  • 배양온도, 먹이생물의 종류에 따라 rotifer 의 성장과 세포크기변화를 알아본 결과 다음과 같다. Large-type rotifer 의 최대세포수는 온도 $36^{\circ}C$, 먹이생물 $\omega$-yeast를 공급한 것에서 배양 7일후 1,420 ind./ml, small-type rotifer에서는 온도 $34^{\circ}C$, 먹이생물 $\omega$- yeast를 공급한 것에서 배양 7일후 1,669 ind./ml로 최고의 성장을 보였다. Rotifer의 크기변화에서는 large-type의 경우 온도 $34^{\circ}C$, 먹이생물 C. ellipsoidea를 공급한 실험구에서 $112.1\mu m$까지 감소되었다 (실험시작시 $202.0\mu m$. Small-type rotifer의 경우는 $320^{\circ}C$, $\omega$-yeast를 먹이로 공급한 것이 배양시작 5일후 $201.3\mu m$까지 증가되었다 (실험시작시 $157.0\mu m$. 크기의 변화가 큰 rotifer에 온도 변화를 다시 주었을 때 처음 실험 시작 때의 rotifer 크기로 회복되었다.

  • PDF

콩(Glycine max)의 종자 함유 Mannose와 Galactose 함량비에 따른 종내변이 (Intraspecific Variation of Glycine max According to the Ratio of Mannose to Galactose in the Seeds)

  • 김창호
    • 한국환경생태학회지
    • /
    • 제25권3호
    • /
    • pp.295-301
    • /
    • 2011
  • 북위 $33^{\circ}15'{\sim}38^{\circ}11'$ 사이에 위치한 한반도 남부의 19개 지역(포천, 고성, 평창, 강화, 금산, 서천, 진천. 단양, 통영, 산청, 금능, 월성, 울릉, 완도, 나주, 고창, 장수, 제주 및 북제주)에서 수집된 콩의 지역개체군들을 대상으로 종자 내에 함유된 mannose와 galactose의 정량분석을 실시하였다. 각 지역별 mannose의 함량은 최저 6.648mg/g (금산)에서 최고 12.207mg/g(고창)의 범위 내에서 다양하게 나타났다. Galactose의 지역별 함량 역시, 최고 16.949mg/g(북제주)에서 최저 9.967mg/g(단양)에 이르는 다양한 수치를 보였다. 환경적응과 관련한 생태지표로서 종자의 경실도(硬實度, seed hardness)를 의미하는 mannose/galactose 함량비를 산출한 결과, 지역에 따라 0.63~0.78의 값을 나타내었다. mannose/galactose 함량비와 지리적 기후구분에 대응하여 콩의 19개 지역개체군 들은 크게 내륙 I형(월성, 장수, 단양), 해안 I형(고창, 나주, 제주, 고성, 울릉, 북제주, 강화, 서천, 통영), 내륙 II형(금산, 포천, 평창) 및 해안 II형(완도, 진천) 등 4가지 변이유형으로 구분되었고 이질적인 2개 지역개체군(금릉과 산청)은 유형구분에서 배제하였다. 이러한 형질분화의 요인으로는 육종이나 기타 다양한 인위적 도태압에 크게 의존하는 재배식물에 있어서도 기후요인과 같은 재배지의 특수한 자연환경조건에 대한 보편적인 적응이 지속적으로 이루어진 결과로 해석된다. 따라서 콩 종자에서 나타나는 mannose/galactose 함량비의 다양성 및 기후형에 대응적인 함량비 서열상의 변이유형 분화는 자연도태와 관련한 재배식물의 미진화 현상에 대한 구체적인 증거의 하나로서 종생태학적인 의의가 큰 것으로 판단된다.