• 제목/요약/키워드: Variation operator

검색결과 113건 처리시간 0.025초

Initial assessment of hemorrhagic shock by trauma computed tomography measurement of the inferior vena cava in blunt trauma patients

  • Lee, Gun Ho;Choi, Jeong Woo
    • Journal of Trauma and Injury
    • /
    • 제35권3호
    • /
    • pp.181-188
    • /
    • 2022
  • Purpose: Inferior vena cava (IVC) collapse is related to hypovolemia. Sonography has been used to measure the IVC diameter, but there is variation depending on the skill of the operator and it is difficult to obtain accurate measurements in patients who have a large amount of intestinal gas or are obese. As a modality to obtain accurate measurements, we measured the diameters of the IVC and aorta on trauma computed tomography scans and investigated the correlation between the IVC to aorta ratio and the shock index in blunt trauma patients. Methods: We retrospectively analyzed the medical records of 588 trauma patients who were transferred to the regional trauma center (level 1) of Wonkang University Hospital from March 2020 to February 2021. We included trauma patients 18 years or older who met the trauma activation criteria and underwent trauma computed tomography scans with intravenous contrast within 40 minutes of admission. The shock index was calculated from vital signs before trauma computed tomography scan, and measurements of the anteroposterior diameter of the IVC (AP), the transverse diameter of the IVC (T), and aorta were made 10 mm above the right renal vein in the venous phase. Results: Overall, 271 patients were included in this study, of whom 150 had a shock index ≤0.7 and 121 had a shock index >0.7. The T to AP ratio and AP to aorta ratio were significantly different between groups. Cutoffs were identified for the T to AP ratio and AP to aorta ratio (2.37 and 0.62, respectively) that produced clinically useful sensitivity and specificity for predicting a shock index >0.7, demonstrating moderate accuracy (T to AP ratio: area under the curve, 0.71; sensitivity, 59%; specificity, 87% and AP to aorta ratio: area under the curve, 0.70; sensitivity, 55%; specificity, 91%). Conclusions: The T to AP ratio and AP to aorta ratio are useful for predicting hemorrhagic shock in trauma patients.

지상기준점 개수 변화에 따른 무인항공 사진측량 성과물의 위치 정확도 분석 (Location Accuracy of Unmanned Aerial Photogrammetry Results According to Change of Number of Ground Control Points)

  • 윤부열;성상민
    • 한국지리정보학회지
    • /
    • 제21권2호
    • /
    • pp.24-33
    • /
    • 2018
  • 무인항공사진측량(UAV Photogrammetry)의 대표적인 성과물인 DSM(Digital Surface Model)과 정사영상은 고품질 공간정보 데이터로써 최근 공간정보산업 여러 분야에서 다양하게 활용되고 있다. 하지만 무인항공사진측량은 무인항공기체의 촬영고도, 촬영 카메라의 캘리브레이션, 촬영 당시의 기상조건, 기체에 사용된 GPS/IMU의 성능, 지상기준점의 개수 등 여러 가지 요인으로 인해 성과물의 품질이 저하되는 문제점을 가지고 있다. 이에 본 연구에서는 지상기준점 개수 변화에 따른 무인항공사진측량 성과물의 위치정확도를 분석하고자 하였다. 실험에 사용한 기체는 고정익 기체이며, 촬영고도는 130m와 260m로 설정하였다. 사용한 지상기준점은 총 9개이며 각각 9, 8, 5, 4개를 사용하였다. 검사점은 연구 대상지에 골고루 분포된 총 10개의 검사점을 사용하였으며, RMSE 분석방법을 사용하여, 정사영상에서는 XY RMSE를 DSM에서는 Z RMSE를 비교 분석하였다. 또한, 정사영상의 해상도가 평면위치 정확도 검증시 작업자의 판단에 영향을 미친다고 판단하여 Siemens star 타겟을 이용하여 시각적해상도를 분석하였다. 분석결과, 지상기준점의 개수가 달라지는 경우 평면위치 정확도의 변화량보다 수직위치 정확도의 변화량이 더 큰 결과를 나타내었으며 촬영고도가 높을수록 지상기준점의 개수의 변화가 위치 정확도에 미치는 영향이 큰 결과를 나타내었다.

심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교 (The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT)

  • 송재혁;김경식;이동훈;김성환;박장원
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.87-92
    • /
    • 2015
  • SPECT에서 Uniformity는 균일한 방사능을 갖는 선원에 대하여 균일한 영상을 제공하는 능력이다. 영상에서 다양한 이유로 불균일이 발생하게 되고, 불균일은 artifacts를 발생시켜 임상적으로 진단하는데 영향을 줄 수 있다. Uniformity correction map은 검사에 사용되는 방사성 동위원소를 이용하여 영상에서 Uniformity의 변동폭을 최소화 시켜주는 역할을 한다. 본원에서 시행되고 있는 $^{201}Tl$을 이용한 심근 SPECT에서는 $^{99m}Tc$으로 기본 설정되어 있는 Uniformity correction map을 사용하고 있으며, 이에 따라 본 연구에서는 $^{201}Tl$$^{99m}Tc$ 두 가지 핵종으로 Uniformity correction map을 각각 설정하였을 때 영상의 질에 차이가 있는지 비교 분석하고, 영상의 질을 최적화 할 수 있는 방법에 대하여 모색해 보고자 한다. 장비는 GE Ventri Gamma camera, Flood phantom, Jaszczak ECT phantom을 이용하였다. 실험에 앞서 Collimator를 제거한 상태에서 Detector 표면 중심으로부터 2.5 m 떨어진 지점에 1 cc 주사기에 $^{99m}Tc$ 25.9 Mbq, $^{201}Tl$ 14.8 Mbq의 방사성 동위원소를 주입한 point source를 이용하여 장비사에서 권고하는 $6{\times}10^7count$$^{99m}Tc$$^{201}Tl$ 각각의 방사성 동위원소로 Uniformity Mapping을 실시하였다. Flood phantom에는 $^{201}Tl$ 21.3 kBq/mL, Jaszczak ECT phantom에는 $^{201}Tl$ 33.4 kBq/mL를 주입하여 phantom을 제작하였다. Flood Phantom으로 획득된 데이터는 Xeleris ver 2.05 프로그램을 이용하여 Integral uniformity, Differential uniformity을 두 가지 항목에 대하여 분석하였다. Jaszczak ECT Phantom으로 획득된 데이터를 본원에서 자체 개발한 Interactive Data Language 프로그램에 입력하여 Integral uniformity, Contrast, Coefficient of variation, Spatial Resolution을 4가지 항목에 대하여 분석하였다. Flood phantom test 에서는 $^{99m}Tc$에서의 Flood I.U값은 3.6%, Flood D.U값은 3.0%으로 나타났고, $^{201}Tl$ Flood I.U값은 3.8%, Flood D.U값은 2.1%으로 나타났다. 이를 통해 $^{201}Tl$으로 Uniformity correction map을 설정하였을 때, Flood I.U값은 감소하였으나 Flood D.U은 향상되어 Flood 영상에서는 크게 영상의 질이 개선되었는지는 알 수 없었다. 반면 Jaszczak ECT Phantom test에서는 $^{99m}Tc$에서의 SPECT I.U값은 13.99%, Coefficient of variation값은 4.89%, contrast값은 0.69, $^{201}Tl$에서의 SPECT I.U값은 11.37%, Coefficient of variation값은 4.79%, contrast값은 0.78로 나타났으며, 육안 분석을 실시한 Spatial Resolution 항목에서는 육안으로 큰 차이를 보이지 않았다. 이를 통해 $^{201}Tl$으로 Uniformity correction map을 설정하였을 때, Spatial Resolution 을 제외한 SPECT I.U, Coefficient of variation, Contrast 세 항목에서 각각 18%, 2%, 13%의 향상된 수치를 보였다는 점에서 영상의 질이 개선되었음을 알 수 있었다. Uniformity correction map이 영상의 질을 크게 좌우할 수 없으나, 개선의 효과를 가져다 준다는 점에서 임상적으로 진단에 영향을 주는지 또한 다른 검사에서 또 다른 방사성 동위원소로 Uniformity correction map을 설정했을 경우 영상의 질을 개선시킬 수 있는지에 관하여 추가적인 연구가 필요할 것으로 사료된다.

  • PDF

교합안정장치 사용 전, 후의 하악과두 위치 변화에 관한 연구 (A STUDY OF CONDYLAR POSITIONAL CHANCES BEFORE & AFTER STABILIZATION SPLINT THERAPY)

  • 이숙경;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제28권1호
    • /
    • pp.113-122
    • /
    • 1998
  • 본 연구는 조선대학교 부속 치과병원 교정과에 내원하여 교정치료를 시행하고 있는 환자중 Panadent 교합기 및 condylar position indicator(CPI)를 이용하여 중심위-중심교합 편위양을 측정한 결과, 전후방 및 수직적 편위양이 1.00mm이내, 측방편위양이 0.30mm 이내인 정상범주를 넘는 부정교합 환자 47명을 대상으로 하여 3개월간 교합안정장치를 24시간 장착하고, CPI 및 transcranial projection을 이용하여 교합안정장치 장착전과 장착후의 하악과두의 위치변화를 관찰한 결과 다음과 같은 결론을 얻었다. 1. CPI상의 모든 군에서 중심교합-중심위 사이에 통계적인 유의성이 있었다(p<0.001). 2. transcranial projection상의 superior joint space의 Rt와 Lt+Rt/2에서 중심교합-중심위 사이에 통계적인 유의성이 있었다(p<0.05). 3. CPI상의 모든 superior-inferior components군에서 교합안정장치 사용 전, 후의 중심교합-중심위 사이에 통계적인 유의성이 있었다(p<0.01). 4. transcranial projection상의 superior joint space의 Rt를 제외한 모든 군에서 교합안정장치 사용 전, 후의 중심교합-중심위 사이에 통계적인 유의성이 없었다. 이상의 결론을 종합해 볼 때 중심교합-중심위 사이의 변화를 평가하는데는 transcranial projection보다 CPI가 보다 유용하며, 교합안정장치는 하악과두의 전, 후방적 위치변화보다는 수직적 위치변화에 미치는 영향이 보다 큰 것으로 보인다.

  • PDF

Response of Rice Yield to Nitrogen Application Rate under Variable Soil Conditions

  • Ahn Nguyen Tuan;Shin Jin Chul;Lee Byun-Woo
    • 한국작물학회지
    • /
    • 제50권4호
    • /
    • pp.247-255
    • /
    • 2005
  • ice yield and plant growth response to nitrogen (N) fertilizer may vary within a field, probably due to spatially variable soil conditions. An experiment designed for studying the response of rice yield to different rates of N in combination with variable soil conditions was carried out at a field where spatial variation in soil properties, plant growth, and yield across the field was documented from our previous studies for two years. The field with area of 6,600 m2 was divided into six strips running east-west so that variable soil conditions could be included in each strip. Each strip was subjected to different N application level (six levels from 0 to 165kg/ha), and schematically divided into 12 grids $(10m \times10m\;for\;each\;grid)$ for sampling and measurement of plant growth and rice grain yield. Most of plant growth parameters and rice yield showed high variations even at the same N fertilizer level due to the spatially variable soil condition. However, the maximum plant growth and yield response to N fertilizer rate that was analyzed using boundary line analysis followed the Mitcherlich equation (negative exponential function), approaching a maximum value with increasing N fertilizer rate. Assuming the obtainable maximum rice yield is constrained by a limiting soil property, the following model to predict rice grain yield was obtained: $Y=10765{1-0.4704^*EXP(-0.0117^*FN)}^*MIN(I-{clay},\;I_{om},\;I_{cec},\;I_{TN},\; I_{Si})$ where FN is N fertilizer rate (kg/ha), I is index for subscripted soil properties, and MIN is an operator for selecting the minimum value. The observed and predicted yield was well fitted to 1:1 line (Y=X) with determination coefficient of 0.564. As this result was obtained in a very limited condition and did not explain the yield variability so high, this result may not be applied to practical N management. However, this approach has potential for quantifying the grain yield response to N fertilizer rate under variable soil conditions and formulating the site-specific N prescription for the management of spatial yield variability in a field if sufficient data set is acquired for boundary line analysis.

해양경찰 함정 실험을 통한 선박충돌 위험도의 변화가 최대인 거리 식별에 관한 연구 (Distance Identification for Maximum Change in Ship Collision Risk through a Coast Guard Patrol Ship Experiment)

  • 김대식;임정빈
    • 해양환경안전학회지
    • /
    • 제23권5호
    • /
    • pp.447-454
    • /
    • 2017
  • 해상에서 두 척의 대형 해양경찰 함정을 이용하여 충돌 가능성이 높은 네 가지 조우방위각($000^{\circ}$, $045^{\circ}$, $090^{\circ}$, $135^{\circ}$)을 설정하여 피험자인 30명의 해양경찰관을 대상으로 조우방위별 거리 3해리(Nautical Mile: NM)에서부터 0.25 NM까지 근접하며 상대거리가 점차 감소될 때 피험자들이 상대선박을 보며 지각한 충돌위험도(Perceived Ship Collision Risk, PSCR)를 측정(0.25 NM 간격으로 기록)하는 실험을 하였고 획득된 데이터를 이용하여 특징을 통계적으로 분석하였다. 본 연구의 목적은 인적오류 예방을 위하여 실선 실험한 선박 조우방위별 상대거리 3 NM에서 0.25 NM까지의 열두 구간에서 획득한 충돌위험도 값을 적정 다항식으로 곡선 근사(Curve Fitting)하여 분포곡선으로 나타내고 특징을 분석하여 항해당직자들이 지각한 충돌위험도의 변화가 최대인 거리를 제시하기 위한 것이다. 분석결과, 각 조우방위에서 거리 구간별 최적의 회귀방정식을 도출하였으며 거리 1.25 1 NM 구간에서 충돌위험도 평균값의 편차가 가장 크게 변화되었고, 특히 1 NM에서 충돌위험도 값이 가장 크게 나타나 실선 실험결과 항해당직자가 지각(Perception)한 충돌위험도의 변화 값이 최대인 거리가 1 NM임을 도출 및 검증하였으며 이는 선박 충돌가능성이 높은 근접상황에서 인적오류 예방 자료로 유용할 것으로 기대된다.

Titanium Implant의 Removal Torque에 관한 연구 (A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS)

  • 이준석;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제32권1호
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

IKONOS 영상자료를 이용한 토지피복도 개선 (Improving of land-cover map using IKONOS image data)

  • 장동호;김만규
    • Spatial Information Research
    • /
    • 제11권2호
    • /
    • pp.101-117
    • /
    • 2003
  • 고해상도 위성영상분석은 국지적 규모의 토지피복 변화 및 대기 상태의 모니터링을 위한 효과적인 기술로 인식되어 왔다. 본 연구에서는 고해상도 영상인 IKONOS 영상과 기존에 작성된 토지이용도를 이용하여 국지적 규모의 토지피복도를 새로 작성하였다. 토지피복 분류기법으로는 퍼지분류 기법을 사용하였으며, 소속함수의 결합방법으로 minimum 연산자를 이용하였다. 분리도 분석에서는 모든 밴드에서 분리도가 높지 않은데, 원인은 계절적 영향에 따른 분광반사율의 차이 때문이다. 토지피복도 작성결과 육상에서는 침엽수림과 경지가, 해양에서는 간석지 및 해빈의 변화가 가장 크다. 분류의 전체정확도는 95.0%, kappa 계수는 0.94%로 나타나 높은 분류정확도를 보였다. 분류항목별 정확도에서는 대부분의 분류항목이 90% 이상의 분류정확도를 보였다. 그러나 혼합림과 하천 및 저수지 등은 낮은 분류정확도를 보였다. 이들 원인은 농경지 담수로 인하여 수역으로 분류항목이 변하거나 유사한 분광패턴으로 분류항목이 혼재된 결과이다. 이들 분류항목의 분류정확도를 높이기 위해서는 계절적 요인을 반드시 고려하여야 할 것이다. 결론적으로 IKONOS 영상은 토지이용도 작성 및 수정이 가능하며, 추후 GIS 공간자료와 통합하여 토지피복도를 작성한다면 보다 정확한 의사결정 보조 자료로서 유용하게 활용될 수 있을 것이다.

  • PDF

Speed-Power Performance Analysis of an Existing 8,600 TEU Container Ship using SPA(Ship Performance Analysis) Program and Discussion on Wind-Resistance Coefficients

  • Shin, Myung-Soo;Ki, Min Suk;Park, Beom Jin;Lee, Gyeong Joong;Lee, Yeong Yeon;Kim, Yeongseon;Lee, Sang Bong
    • 한국해양공학회지
    • /
    • 제34권5호
    • /
    • pp.294-303
    • /
    • 2020
  • This study discusses data collection, calculation of wind and wave-induced resistance, and speed-power analysis of an 8,600 TEU container ship. Data acquisition system of the ship operator was improved to obtain the data necessary for the analysis, which was accomplished using SPA (Ship Performance Analysis, Park et al., 2019) in conformation with ISO15016:2015. From a previous operation profile of the container, the standard operating conditions of mean draft were 12.5 m and 13.6 m, which were defined with the mean stowage configuration of each condition. Model tests, including the load-variation test, were conducted to validate new ship performance and for the speed-power analysis. The major part of the added resistance of container ship is due to the wind. To check the reliability of wind-resistance calculation results, the resistance coefficients, added resistance, and speed-power analysis results using the Fujiwara regression formula (ISO15016:2015) and Computational fluid dynamics (Ryu et al., 2016; Jeon et al., 2017) analysis were compared. Wind speed and direction measured using an anemometer were used for wind-resistance calculation and the wave resistance was calculated using the wave-height and direction-data from weather information. Also, measured water temperature was used to calculate the increase in resistance owing to the deviation in water density. As a result, the SPA analysis using measured data and weather information was proved to be valid and able to identify the ship's resistance propulsion performance. Even with little difference in the air-resistance coefficient value, both methods provide sufficient accuracy for speed-power analysis. The differences were unnoticeable when the speed-power analysis results using each method were compared. Also, speed-power analysis results of the 8,600 TEU container ship in two draft conditions show acceptable trends when compared with the model test results and are also able to show power increase owing to hull fouling and aging. Thus, results of speed-power analysis of the existing 8,600 TEU container ship using the SPA program appropriately exhibit the characteristics of speed-power performance in deal conditions.

팬텀연구에서 경직장 전단파탄성초음파의 가변성 (Variability of Transrectal Shear Wave Elastography in a Phantom Model)

  • 이지현;윤성국;조진한;권희진;김동원;이준우
    • 대한영상의학회지
    • /
    • 제84권5호
    • /
    • pp.1110-1122
    • /
    • 2023
  • 목적 본 연구는 제작한 팬텀을 사용해 경직장 전단파탄성초음파의 가변성을 알아보았다. 대상과 방법 아가로즈와 실리콘에멀전을 각각 1, 2, 3 cm 크기의 둥근 모양과 사각 모양의 팬텀 물질로 제작하였다. 1, 2, 3 cm의 깊이에 팬텀을 놓고, 크기, 깊이, 모양에 따른 굳기값(coefficient variant)의 차이를 중심부/주변부에서 확인하였다. 두 명의 영상의가 경직장 초음파 탐촉자를 이용해 각각 3회씩, 두 개의 초음파기계로(기계 A, B), 굳기값을 확인하였다. 가변성은 변동계수로 표현하였다. 결과 팬텀의 크기가 커질수록 변동계수는 감소하였다. 크기에 따른 굳기값은, 아가로즈 팬텀은 기계 A 3 cm 깊이(p < 0.001), 기계 B 1 cm 깊이에서(p = 0.010), 실리콘에멀전 팬텀은 2 cm 깊이에서 두 기계 모두 유의한 차이를 보였다(p = 0.047, p = 0.020). 깊이가 깊어질수록 변동계수는 증가하였다. 깊이에 따른 굳기값은, 1 cm 크기 아가로즈 팬텀은 두 기계 모두(p = 0.037, p = 0.021), 2 cm 크기 아가로즈 팬텀은 기계 A에(p = 0.047) 유의한 차이를 보였다. 기계 A 실리콘에멀전에서만 모양에 따른 굳기값의 유의한 차이를 보였고(p = 0.032) 기계 B는 두 물질 모두 관심영역에 따른 굳기값의 유의한 차이가 보였다. 굳기값은 두 기계 간 유의한 차이가 있었고(p < 0.05), 시술자 내/시술자 간 일치도는 높았다(급내상관계수 > 0.9). 결론 팬텀의 크기, 깊이, 사용된 기계가 전단파탄성초음파 가변성에 영향을 주는 요소로 나타났다.