• 제목/요약/키워드: Variation Specifications

Search Result 114, Processing Time 0.033 seconds

Performance Test of $3^{rd}$ rail type power collector for rubber-tired AGT light rail vehicle (고무차륜 AGT 경량전철 차량용 제 3 궤조 집전장치의 성능시험)

  • Park S.H.;Kim Y.S.;Kim K.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1341-1344
    • /
    • 2005
  • This study was aimed to verify the acceptable contact force between power collector and 3rd rail type conductor rail for the Korean standardized rubber-tired AGT light rail vehicle. The power collector was designed and manufactured to satisfy the Korean standardized Specifications of the rubber-tired AGT light rail vehicle. Based on the dynamic behavior, contact force variation and interruption in the worst installation tolerance of the conductor rail, its initial contact force was set up. At the test track for the Korean standardized rubber-tired AGT light rail vehicle, interruptions, stresses, vibrations, and contact force variations were measured. As the results, initial contact force was verified to ensure power collection stability.

  • PDF

Electrical interruption characteristics of 3rd rail type power collector for rubber-tired AGT light rail vehicle (고무차륜 AGT 경량전철 차량용 제 3 궤조 집전장치의 이선특성)

  • 박성혁;김연수;윤성철;전현규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.556-559
    • /
    • 2004
  • This study was aimed to verify the acceptable contact force between power collector and 3rd rail type conductor rail for the Korean standardized rubber-tired AGT light rail vehicle. The power collector was designed and manufactured to satisfy the Korean standardized Specifications of the rubber-tired AGT light rail vehicle. Based on the dynamic behavior, contact force variation and interruption in the worst installation tolerance of the conductor rail, its initial contact force was set up. With rotary disk type equivalent test apparatus with circular conductor rail, the interruptions were measured. As the results, acceptable contact force was proposed to ensure power collection stability.

  • PDF

IMT-2000 진화 시스템 기술 소개

  • 김종헌;이기헌;최고희;최진성
    • Information and Communications Magazine
    • /
    • v.21 no.7
    • /
    • pp.37-48
    • /
    • 2004
  • Both the 1xEV-DV and HSDPA are advanced standards which can make high speed packet data services come true in mobile communications environment. Both specifications look similar in a point of allocating their radio access resources based on the real-time variation of wireless channels. This paper introduces BTS modems and channel cards for 1xEV-DV and HSDPA developed by LG Electronics, Inc.

Review of Design Flexural Strengths of Steel-Concrete Composite Beams for Building Structures

  • Chung, Lan;Lim, Jong-Jin;Hwang, Hyeon-Jong;Eom, Tae-Sung
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.sup3
    • /
    • pp.109-121
    • /
    • 2016
  • Recently, as the use of high-performance materials and complex composite methods has increased, the need for advanced design specifications for steel-concrete composite structures has grown. In this study, various design provisions for ultimate flexural strengths of composite beams were reviewed. Design provisions reviewed included the load and resistance factor design method of AISC 360-10 and the partial factor methods of KSSC-KCI, Eurocode 4 and JSCE 2009. The design moment strengths of composite beams were calculated according to each design specification and the variation of the calculated strengths with design variables was investigated. Furthermore, the relationships between the deformation capacity and resistance factor for flexure were examined quantitatively. Results showed that the design strength and resistance factor for flexure of composite beams were substantially affected by the design formats and variables.

Characteristics of 3rd Rail Type Power Collector for the Rubber-Tired AGT Light Rail Vehicle (고무차륜 AGT 경량전철용 제3궤조 집전장치 특성해석)

  • Kim Y.S.;Jeong KG.;Park S.H.;Baeg N.U.
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.832-836
    • /
    • 2004
  • This study was aimed to establish the acceptable contact force range between power collector and 3rd rail type conductor rail, and ramp slope for the Korean standardized rubber-tired AGT light rail vehicle. Dynamic behavior of the power collector, contact force variation and interruption in operation, were analyzed in the worst installation tolerance and various ramp slope of the conductor rail. The power collector was designed and manufactured to satisfy the Korean Standardized Specifications of the rubber-tired AGT light rail vehicle.

  • PDF

Design Parameters of Small Hydro Power Sites for River Systems(I) (소수력발전입지의 수계별 설계변수 특성(I))

  • Park, Wan-Soon;Lee, Chul-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.86-91
    • /
    • 2010
  • The characteristics of hydrologic design parameters for small hydro power(SHP) sites located in four major river systems have been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the variation of inflow. And another model to predict hydrologic performance for SHP plants is established. The results from hydrologic performance analysis for SHP sites located on five major river systems based on the models developed in this study show that the specific design flowrate and specific output of SHP site have large difference between the river systems. The load factor, however, have small difference compared with specific design flowrate and specific output for all river systems. Also, it was found that the models developed in this study can be used to predict the primary design specifications of SSHP plants effectively.

Robust Control of DC-DC Converter by Approximate 2DOF Digital Controller Realizing First-Order Model

  • Higuch, Kohji;Takegami, Eiji;Nakano, Kazushi;Tomioka, Satoshi;Watanabe, Kazushi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.794-799
    • /
    • 2005
  • Robust DC-DC converter which can cover extensive load changes and also input voltage changes with one controller is needed. In this paper, we propose a method for determining the parameters of 2DOF digital controller which makes the control bandwidth wider, and at the same time makes a variation of the output voltage very small at sudden changes of resistive load and the input voltage. The 2DOF digital controller whose parameters are determined by the proposed method is actually implemented on a DSP and is connected to a DC-DC converter. Experimental studies demonstrate that this type of digital controller can satisfy given specifications.

  • PDF

Hardware-In-The-Loop Simulation (HILS) Based Design and Robustness Evaluation of an Intelligent Gantry Crane System

  • ;Jalani, Jamaludin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1729-1734
    • /
    • 2005
  • The use of gantry crane systems for transporting payload is very common in industrial application. However, moving the payload using the crane is not an easy task especially when strict specifications on the swing angle and on the transfer time need to be satisfied. To overcome this problem, this paper describes development of an intelligent gantry crane system based on the mechatronic design. A lab-scale gantry crane is designed and then its intelligent controllers are developed. Fuzzy logic controllers are adopted, designed and implemented for controlling payload position as well as the swing angle of the gantry crane. The performance of the intelligent gantry crane system is evaluated on a hardware-in-the-loop simulation (HILS) environment. Moreover robustness of the proposed system is also evaluated. The result shows that the intelligent gantry crane system designed based on the mechatronic design approach has better performance compared with the automatic gantry crane system controlled by classical PID controllers. Moreover simulation result shows that the intelligent gantry crane system is more robust to parameter variation than the automatic gantry crane system.

  • PDF

$H_\infty$ Optimal Controller Synthesis by the Frequency Domain Analysis of Weighting Function (가중함수의 주파수 영역 해석에 따른 $H_\infty$ 최적 제어기 구성)

  • Kim, Yong-Gyu;Ryu, Chang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.2
    • /
    • pp.8-15
    • /
    • 2000
  • This study presents an H$_{\infty}$ optimal controller synthesis by the frequency domain analysis of weighting function. The main purpose of our study is to visualize weighting function domains and open loop transfer function domains that satisfy robustness and performance. Also we aim to simplify the iterative algorithm for H$\infty$ optimal controller synthesis. We report that the designed regulator by the proposed method in this paper satisfies the desired specifications and performance in spite of the plant uncertainty variation at any operating point.

  • PDF

Studies on the Content Uniformity of Pharmaceuticals -On the Content Uniformity of Phenformin Hydrochloride and Chlorpheniramine Maleate Tablets- (의약품(醫藥品)의 Content Uniformity에 관(關)한 연구(硏究) -Phenformin hydrochloride정(錠) 및 Chlorpheniramine maleate정(錠)의 Content Uniformity에 관(關)하여-)

  • Baek, Kyung-Ja;Yong, Jae-Ick
    • Journal of Pharmaceutical Investigation
    • /
    • v.6 no.2
    • /
    • pp.58-68
    • /
    • 1976
  • 120 tablets of 25mg phenformin hydrochloride tablet and 4mg chlorpheniramine maleate tablet, respectively, were assayed and analyzed to obtain basic data on the content uniformity of domestic pharmaceuticals. All of the tablets of phenformin hydrochloride and that of chlorpheniramine maleate were met the requirements of the test for weight variation and content but no regularity was found in the content unformity specifications. In case of chlorpheniramine maleate tablets, standard deviation of active ingredient content of B maker was 4.1% and that of C maker 7.1%.

  • PDF