• Title/Summary/Keyword: Variance Values

Search Result 1,034, Processing Time 0.027 seconds

Genetic parameters for worm resistance in Santa Inês sheep using the Bayesian animal model

  • Rodrigues, Francelino Neiva;Sarmento, Jose Lindenberg Rocha;Leal, Tania Maria;de Araujo, Adriana Mello;Filho, Luiz Antonio Silva Figueiredo
    • Animal Bioscience
    • /
    • v.34 no.2
    • /
    • pp.185-191
    • /
    • 2021
  • Objective: The objective of this study was to estimate the genetic parameters for worm resistance (WR) and associated characteristics, using the linear-threshold animal model via Bayesian inference in single- and multiple-trait analyses. Methods: Data were collected from a herd of Santa Inês breed sheep. All information was collected with animals submitted to natural contamination conditions. All data (number of eggs per gram of feces [FEC], Famacha score [FS], body condition score [BCS], and hematocrit [HCT]) were collected on the same day. The animals were weighed individually on the day after collection (after 12-h fasting). The WR trait was defined by the multivariate cluster analysis, using the FEC, HCT, BCS, and FS of material collected from naturally infected sheep of the Santa Inês breed. The variance components and genetic parameters for the WR, FEC, HCT, BCS, and FS traits were estimated using the Bayesian inference under the linear and threshold animal model. Results: A low magnitude was obtained for repeatability of worm-related traits. The mean values estimated for heritability were of low-to-high (0.05 to 0.88) magnitude. The FEC, HCT, BCS, FS, and body weight traits showed higher heritability (although low magnitude) in the multiple-trait model due to increased information about traits. All WR characters showed a significant genetic correlation, and heritability estimates ranged from low (0.44; single-trait model) to high (0.88; multiple-trait model). Conclusion: Therefore, we suggest that FS be included as a criterion of ovine genetic selection for endoparasite resistance using the trait defined by multivariate cluster analysis, as it will provide greater genetic gains when compared to any single trait. In addition, its measurement is easy and inexpensive, exhibiting greater heritability and repeatability and a high genetic correlation with the trait of resistance to worms.

Part II. What drives Korean adults to seek orthodontic treatment: Factors contributing to orthodontic treatment decisions

  • Oh, Min-Hee;Park, Ae-Hyun;Kim, MinSoo;Kim, Eun-A;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.51 no.1
    • /
    • pp.3-14
    • /
    • 2021
  • Objective: This study aimed to identify the perceptions of orthodontic treatment among Korean adults and determine the factors that drive them to seek orthodontic treatment. Methods: A total of 2,321 adults aged 19-64 years were surveyed using an internet research system from a specialized research company. The participants were divided into the following groups based on their experience of and willingness to undergo orthodontic treatment: experience, acceptance, and non-acceptance groups. The characteristics of the participants were compared using analysis of variance with post-hoc analysis. Multinomial logistic regression analysis was performed in all three models with the non-acceptance group as a reference. Results: In terms of demographic characteristics, age, gender, marital status, and education had significant influences on orthodontic treatment decisions in adults in the experience and acceptance groups (p < 0.001). When all the factors were analyzed, age, marital status, past dental treatment experience, regular oral examinations, demand for orthodontic treatment, optimal treatment period, health insurance coverage, information on orthodontic treatments, perceptions regarding orthodontic treatment, and psychosocial impact of dental esthetics significantly influenced orthodontic treatment decisions in adults in the experience and acceptance groups (p < 0.001). Conclusions: These findings suggest that various factors influence orthodontic treatment decisions in adults. Individuals who seek orthodontic treatment were found to undergo more regular dental treatment and oral examination than those who did not. They also had a better perception of orthodontic treatment and more negative values for the psychosocial impact of dental esthetics.

Validity and Reliability of the Korean Version of Person-Centered Practice Inventory-Staff for Nurses (간호사 대상 한국어판 인간중심돌봄 측정도구의 타당도와 신뢰도)

  • Kim, Sohyun;Tak, Sunghee H
    • Journal of Korean Academy of Nursing
    • /
    • v.51 no.3
    • /
    • pp.363-379
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the validity and reliability of the Korean version of Person-Centered Practice Inventory-Staff (PCPI-S) for nurses. Methods: The English PCPI-S was translated into Korean with forward and backward translation. Data were collected from 338 nurses at one general hospital in Korea. Construct validity was evaluated with confirmatory factor analysis, convergent validity, and discriminant validity. Known-group validity was also evaluated. Cronbach's α was used to assess the reliability. Results: The PCPI-S Korean version consisted of 51 items in three areas: prerequisites, the care environment, and person-centered process. The comparative fit index (CFI) and values of person-centered care process were improved after engagement and having sympathetic presence items were combined as one component. The construct validity of PCPI-S Korean version was verified using four-factor structures (.05 < RMSEA < .10, AGFI > .70, CFI > .70, and AIC). The convergent validity and discriminant validity of the entire PCPI-S question were verified using a two-factor structures (AVE > .50, construct reliability > .70). There was an acceptable known-group validity with a significant correlation between the PCPI-S level and the degree of person-centered care awareness and education. Internal consistency was reliable with Cronbach's α .95. Conclusion: The Korean version of PCPI-S is valid and reliable. It can be used as a standardized Korean version of person-centered care measurement tool. Abbreviation: RMSEA = root mean square error of approximation; AGFI = adjusted goodness of fit index; AIC = Akaike information criterion; AVE = average variance extracted.

CFD Study for the Design of Coolant Path in Cryogenic Etch Chuck

  • Jo, Soo Hyun;Han, Ji Hee;Kim, Jong Oh;Han, Hwi;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.2
    • /
    • pp.92-97
    • /
    • 2021
  • The importance of processes in cryogenic environments is increasing in a way to address problems such as critical dimension (CD) narrow and bottlenecks in micro-processing. Accordingly, in this paper, we proceed with the design and analysis of Electrostatic Chuck(ESC) and Coolant in cryogenic environments, and present optimal model conditions to provide the temperature distribution analysis of ESC in these environments and the appropriate optimal design. The wafer temperature uniformity was selected as the reference model that the operating conditions of the refrigerant of the liquid nitrogen in the doubled aluminum path were excellent. Design of simulation (DOS) was carried out based on the wheel settings within the selected reference model and the classification of three mass flow and diameter case, respectively. The comparison between factors with p-value less than 0.05 indicates that the optimal design point is when five turns of coolant have a flow rate of 0.3 kg/s and a diameter of 12 mm. ANOVA determines the interactions between the above factor, indicating that mass flow is the most significant among the parameters of interests. In variable selection procedure, Case 2 was also determined to be superior through the two-Sample T-Test of the mean and variance values by dividing five coolant wheels into two (Case 1 : 2+3, Case 2: 3+2). Finally, heat transfer analysis processes such as final difference method (FDM) and heat transfer were also performed to demonstrate the feasibility and adequacy of the analysis process.

A study on the improvement of seamless knitwear sleeve design (무봉제 니트웨어의 소매디자인 향상을 위한 연구)

  • Kang, Hee Myung;Ki, Hee-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.4
    • /
    • pp.57-71
    • /
    • 2021
  • The purpose of the study is to derive an appropriate knitting method that can increase the appearance, wearability, and functionality through empirical research on the sleeve height knitting ratio of seamless knit wear. The study was conducted by producing seven types of experiment clothes according to knitting ratio to examine the characteristics according to the body armhole and sleeve height ratio. Specifically, after fit evaluatins, variance analysis (ANOVA) was performed to analyze the results of the evaluation, and the evaluated contents were converted into data. Among them, the items with significant results were intensively studied using the Duncan-test. The result showed that the height and the width of the sleeves vary depending on the knitting ratio. Test sweater A was the highest at 16cm, followed by test sweater B, test sweater C, test sweater D, test sweater E, test sweater F, and test sweater G at 4cm. The 1:1 ratio of test sweater A, was the highest, which is knitted in the same course as the body. The larger the difference in the ratio of body and sleeve, the lower the height of the sleeves. As a result of the appearance sensory evaluation, a significant difference was confirmed in the result values (p<0.001) from all items on the front, side, and rear. Specifically, the appearance of the test sweater B(2:4:2) on the front and test sweater C(2:4:3) on the side and rear side was the best. When the sleeves height is properly set, the ratio of the arm line to fit the design with a natural curve is analyzed as a very important factor. The results of this study are expected to be of practical use in product development and production that can increase the feeling when wearing and design satisfaction.

Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods

  • Mai, Hai Yen;Mai, Hang-Nga;Lee, Cheong-Hee;Lee, Kyu-Bok;Kim, So-yeun;Lee, Jae-Mok;Lee, Keun-Woo;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.88-95
    • /
    • 2022
  • PURPOSE. This study investigated the accuracy of full-arch intraoral scans obtained by various scan strategies with the segmental scan and merge methods. MATERIALS AND METHODS. Seventy intraoral scans (seven scans per group) were performed using 10 scan strategies that differed in the segmental scan (1, 2, or 3 segments) and the scanning motion (straight, zigzag, or combined). The three-dimensional (3D) geometric accuracy of scan images was evaluated by comparison with a reference image in an image analysis software program, in terms of the arch shape discrepancies. Measurement parameters were the intermolar distance, interpremolar distance, anteroposterior distance, and global surface deviation. One-way analysis of variance and Tukey honestly significance difference post hoc tests were carried out to compare differences among the scan strategy groups (α = .05). RESULTS. The linear discrepancy values of intraoral scans were not different among scan strategies performed with the single scan and segmental scan methods. In general, differences in the scan motion did not show different accuracies, except for the intermolar distance measured under the scan conditions of a 3-segmental scan and zigzag motion. The global surface deviations were not different among all scan strategies. CONCLUSION. The segmental scan and merge methods using two scan parts appear to be reliable as an alternative to the single scan method for full-arch intraoral scans. When three segmental scans are involved, the accuracy of complete arch scan can be negatively affected.

Long-gap Filling Method for the Coastal Monitoring Data (해양모니터링 자료의 장기결측 보충 기법)

  • Cho, Hong-Yeon;Lee, Gi-Seop;Lee, Uk-Jae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.33 no.6
    • /
    • pp.333-344
    • /
    • 2021
  • Technique for the long-gap filling that occur frequently in ocean monitoring data is developed. The method estimates the unknown values of the long-gap by the summation of the estimated trend and selected residual components of the given missing intervals. The method was used to impute the data of the long-term missing interval of about 1 month, such as temperature and water temperature of the Ulleungdo ocean buoy data. The imputed data showed differences depending on the monitoring parameters, but it was found that the variation pattern was appropriately reproduced. Although this method causes bias and variance errors due to trend and residual components estimation, it was found that the bias error of statistical measure estimation due to long-term missing is greatly reduced. The mean, and the 90% confidence intervals of the gap-filling model's RMS errors are 0.93 and 0.35~1.95, respectively.

Development and Validation of a Korean Nursing Work Environment Scale for Critical Care Nurses (한국형 중환자실 간호근무환경 측정도구 개발 및 평가)

  • Lee, Hyo Jin;Moon, Ji Hyun;Kim, Se Ra;Shim, Mi Young;Kim, Jung Yeon;Lee, Mi Aie
    • Journal of Korean Clinical Nursing Research
    • /
    • v.27 no.3
    • /
    • pp.279-293
    • /
    • 2021
  • Purpose: The purpose of this study was to develop a Korean nursing work environment scale for critical care nurses (KNWES-CCN) and verify its validity and reliability. Methods: A total of 46 preliminary items were selected using content validity analysis of experts on 64 candidate items derived through literature reviews and in-depth interviews with critical care nurses. 535 critical care nurses from 21 hospitals responded to the preliminary questionnaire from February to March 2021. The collected data were analysed using construct, convergent and discriminant validities, and internal consistency and test-retest reliability. Results: The 23 items in 4 factors accounted for 55.6% of the total variance were identified through item analysis and exploratory factor analysis (EFA). EFA was performed with maximum likelihood method including direct oblimin method. In the confirmatory factor analysis, KNWES-CCN consisted of 21 items in 4 factors by deleting the items that were not meet the condition that the factor loading over .50 or the squared multiple correlation over .30. This model was considered to be suitable because it satisfied the fit index and acceptable criteria of the model [𝒳2=440.47 (p<.001), CMIN/DF=2.41, GFI=.86, SRMR=.06, RMSEA=.07, TLI=.90, CFI=.91]. The item total correlation values ranged form .32 to .73 and its internal consistency was Cronbach's α=.92. The reliability of the test-retest correlation coefficient was .72 and the intra-class correlation coefficient was .83. Conclusion: The KNWES-CCN showed good validity and reliability. Therefore, it is expected that the use of this scale would measure and improve nursing work environment for critical care nurses in Korea.

Comparison of Clinical Characteristics of Fluorescence in Quantitative Light-Induced Fluorescence Images according to the Maturation Level of Dental Plaque

  • Jung, Eun-Ha;Oh, Hye-Young
    • Journal of dental hygiene science
    • /
    • v.21 no.4
    • /
    • pp.219-226
    • /
    • 2021
  • Background: Proper detection and management of dental plaque are essential for individual oral health. We aimed to evaluate the maturation level of dental plaque using a two-tone disclosing agent and to compare it with the fluorescence of dental plaque on the quantitative light-induced fluorescence (QLF) image to obtain primary data for the development of a new dental plaque scoring system. Methods: Twenty-eight subjects who consented to participate after understanding the purpose of the study were screened. The images of the anterior teeth were obtained using the QLF device. Subsequently, dental plaque was stained with a two-tone disclosing solution and a photograph was obtained with a digital single-lens reflex (DSLR) camera. The staining scores were assigned as follows: 0 for no staining, 1 for pink staining, and 2 for blue staining. The marked points on the DSLR images were selected for RGB color analysis. The relationship between dental plaque maturation and the red/green (R/G) ratio was evaluated using Spearman's rank correlation. Additionally, different red fluorescence values according to dental plaque accumulation were assessed using one-way analysis of variance followed by Scheffe's post-hoc test to identify statistically significant differences between the groups. Results: A comparison of the intensity of red fluorescence according to the maturation of the two-tone stained dental plaque confirmed that R/G ratio was higher in the QLF images with dental plaque maturation (p<0.001). Correlation analysis between the stained dental plaque and the red fluorescence intensity in the QLF image confirmed an excellent positive correlation (p<0.001). Conclusion: A new plaque scoring system can be developed based on the results of the present study. In addition, these study results may also help in dental plaque management in the clinical setting.

Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study

  • Osman, Reham;Alharbi, Nawal
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.294-304
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches. MATERIALS AND METHODS. Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights- Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3ShapeTM, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05. RESULTS. The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (P=.959 and P=.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III. CONCLUSION. The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.