• Title/Summary/Keyword: Variable speed generator

Search Result 184, Processing Time 0.024 seconds

Experimental Study on Efficiency of Floating Vertical Axis Wind Turbine with Variable-Pitch (부유식 가변 피치형 수직축 풍력발전기의 발전효율에 관한 실험 연구)

  • Kim, Jae-Heui;Jo, Hyo-Jae;Hwang, Jae-Hyuk;Jang, Min-Suk;Lee, Byeong-Seong
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.202-207
    • /
    • 2018
  • This paper presents the efficiency of a floating vertical axis wind turbine with variable-pitch. A model was designed to use the lift force and drag force for blades with various pitch angles. The blade's pitch angle is controlled by the stopper. To validate the efficiency of the wind turbine discussed in this paper, a model test was carried out through a single model efficiency experiment and wave tank experiment. The parameters of the single model efficiency experiment were the wind speed, electronic load, and pitch angle. The wave tank experiment was performed using the most efficient pitch angle from the results of the single model efficiency experiment. According to the results of the wave tank experiment, the surge and pitch motion of a structure slightly affect the efficiency of a wind turbine, but the heave motion has a large effect because the heights of the wind turbine and wind generator are almost the same.

Rotor Speed-based Droop of a Wind Generator in a Wind Power Plant for the Virtual Inertial Control

  • Lee, Jinsik;Kim, Jinho;Kim, Yeon-Hee;Chun, Yeong-Han;Lee, Sang Ho;Seok, Jul-Ki;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1021-1028
    • /
    • 2013
  • The frequency of a power system should be kept within limits to produce high-quality electricity. For a power system with a high penetration of wind generators (WGs), difficulties might arise in maintaining the frequency, because modern variable speed WGs operate based on the maximum power point tracking control scheme. On the other hand, the wind speed that arrives at a downstream WG is decreased after having passed one WG due to the wake effect. The rotor speed of each WG may be different from others. This paper proposes an algorithm for assigning the droop of each WG in a wind power plant (WPP) based on the rotor speed for the virtual inertial control considering the wake effect. It assumes that each WG in the WPP has two auxiliary loops for the virtual inertial control, i.e. the frequency deviation loop and the rate of change of frequency (ROCOF) loop. To release more kinetic energy, the proposed algorithm assigns the droop of each WG, which is the gain of the frequency deviation loop, depending on the rotor speed of each WG, while the gains for the ROCOF loop of all WGs are set to be equal. The performance of the algorithm is investigated for a model system with five synchronous generators and a WPP, which consists of 15 doubly-fed induction generators, by varying the wind direction as well as the wind speed. The results clearly indicate that the algorithm successfully reduces the frequency nadir as a WG with high wind speed releases more kinetic energy for the virtual inertial control. The algorithm might help maximize the contribution of the WPP to the frequency support.

3MW Class Offshore Wind Turbine Development (3MW급 해상풍력 발전시스템 개발)

  • Joo, Wan-Don;Lee, Jeong-Hoon;Kim, Jeong-Il;Jeong, Seok-Yong;Shin, Young-Ho;Park, Jong-Po
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.491-494
    • /
    • 2009
  • This paper introduces the design concepts and characteristics of WinDS3000$^{TM}$ which is a trade mark of Doosan's 3MW offshore/onshore wind turbine. WinDS3000$^{TM}$ has been designed in consideration of high RAMS (Reliability, Availability, Maintainability and Serviceability) and cost effectiveness for the TC Ia condition in GL guideline. An integrated drive train design with an innovative three-stage gearbox has been introduced to minimize nacelle weight of the wind turbine and to enhance a high reliability for transmission. A permanent magnet generator with full converter system has been introduced to get higher efficiency in part load operation, and grid friendliness use of 50 Hz and 60 Hz grid. A pitch regulated variable speed power control with individual pitch system has been introduced to regulate rotor torque while generator reaction torque can be adjusted almost instantaneously by the associated power electronics. An individual pitch control system has been introduced to reduce fatigue loads of blade and system. The wind turbine has been also equipped with condition monitoring and diagnostic systems in order to meet maintainability requirements. And internal maintenance crane in nacelle has been developed. As a result, the maintenance cost was dramatically reduced and maintenance convenience also enhanced in offshore condition.

  • PDF

Design of DSP(TMS320F240) Controller for Multi-axes Transportation System with BLDC Servo Motor (DSP(TMS320F240)를 이용한 BLDC서보 전동기 다축 이송시스템 제어기 설계)

  • 김민섭;구효원;최중경;권현아;신영호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.95-98
    • /
    • 2002
  • This paper presents a study on DSP(TMS320F240) controller design for multi-axes transportation system using BLDC servo motor. This BLDC servo motor controller was realized with DSP(Digital Signal Processor) and IPM (Intelligent Power Module). The multi-axes transportation system needs torque, speed, position control of servo motor for variable action. This paper implements those servo control with vector control and space vector modulation technique. As CPU of controller DSP(TMS320F240) is adopted because, it has PWM(Pulse Width Modulation) waveform generator, A/D(Analog to Digital) converter, SPI(Serial Peripheral Interface) port and input/output port etc. The controller of multi-axes transportation system consists of 3-level hierarchy structure that main host PC manages three sub DSP system which transfer downword command and are monitoring the states of end servo controllers. Each sub DSP system operates eight BLDC servo controllers which control BLDC servo motor using DSP and IPM Between host system and middle digital signal processor communicate with RS-422, between main processor and controller communicate with SPI port.

  • PDF

Power Control of MW Wind Turbine (MW급 풍력터빈의 출력 제어)

  • Nam, Yoon-Su;Kim, Jeong-Gi;Choi, Han-Soon;Cho, Jang-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.1
    • /
    • pp.11-15
    • /
    • 2011
  • In this paper, a methodology for the power control of a wind turbine, which is the variable-speed and variable-pitch (VSVP) control system, is introduced. This control methodology maximizes the capability of the turbine to extract maximum power from the wind in the regions with low wind speeds. Further, it regulates the wind-turbine power as the rated power in the case of the regions with high wind speeds. A simple drive train model is used to design the VSVP control system. The methodology for VSVP control is mechanized by controlling the generator torque and blade pitch. Finally, some simulation results for the VSVP control to a MW wind turbine are discussed in this paper.

On a High-speed Implementation of LILI-II Stream Cipher (LILI-II 스트림 암호의 고속화 구현에 관한 연구)

  • 이훈재;문상재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1210-1217
    • /
    • 2004
  • LILI-II stream cipher is an upgraded version of the LILI-128, one of candidates in NESSIE. Since the algorithm is a clock-controlled, the speed of the keystream data is degraded structurally in a clock-synchronized hardware logic design. Accordingly, this paper proposes a 4-bit parallel LFSR, where each register bit includes four variable data routines for feedback or shifting within the LFSR. furthermore, the timing of the proposed design is simulated using a Max+plus II from the ALTERA Co., the logic circuit is implemented for an FPGA device (EPF10K20RC240-3), and apply to the Lucent ASIC device (LV160C, 0.13${\mu}{\textrm}{m}$ CMOS & 1.5v technology), and it could achieve a throughput of about 500 Mbps with a 0.13${\mu}{\textrm}{m}$ semiconductor for the maximum path delay below 1.8㎱. Finally, we propose the m-parallel implementation of LILI-II, throughput with 4, 8 or 16 Gbps (m=8, 16 or 32).

Design and Performance Evaluation of a Variable Control Type Fresh Corn Harvester (가변 제어형 식용 풋옥수수 수확기 설계 및 성능평가)

  • Jea Keun Woo;Il Su Choi;Young Keun Kim;Yong Choi;Duck Kyu Choi;Ho Seop Lee;Ji Tae Kim;Young Jun Park;Dong jae Kim
    • Journal of Drive and Control
    • /
    • v.20 no.2
    • /
    • pp.40-46
    • /
    • 2023
  • Fresh corn, one of the main food crops, must be harvested by hand. A harvest mechanization technology is required. In this study, a tractor-attached harvester was designed and manufactured to sequentially perform stem reaping, fresh corn detaching, and collecting. The(harvester was designed so that the main device could operate through a hydraulic pump and a generator could be operated through the tractor's PTO. Factor tests were conducted according to cultivars (Ilmichal, Super sweet corn) and working speed (0.12 m/s, 0.17, 0.22). After the factor test, detached corns ratio, collected corns ratio, and damaged corns ratio were analyzed and harvest performance was evaluated. Harvesting performance was good for super sweet corn. Considering operation efficiency, 0.22 m/s was judged to be an appropriate working speed. It was found that it took two hours to work an area of 10 a.

A Dual-Mode 2.4-GHz CMOS Transceiver for High-Rate Bluetooth Systems

  • Hyun, Seok-Bong;Tak, Geum-Young;Kim, Sun-Hee;Kim, Byung-Jo;Ko, Jin-Ho;Park, Seong-Su
    • ETRI Journal
    • /
    • v.26 no.3
    • /
    • pp.229-240
    • /
    • 2004
  • This paper reports on our development of a dual-mode transceiver for a CMOS high-rate Bluetooth system-onchip solution. The transceiver includes most of the radio building blocks such as an active complex filter, a Gaussian frequency shift keying (GFSK) demodulator, a variable gain amplifier (VGA), a dc offset cancellation circuit, a quadrature local oscillator (LO) generator, and an RF front-end. It is designed for both the normal-rate Bluetooth with an instantaneous bit rate of 1 Mb/s and the high-rate Bluetooth of up to 12 Mb/s. The receiver employs a dualconversion combined with a baseband dual-path architecture for resolving many problems such as flicker noise, dc offset, and power consumption of the dual-mode system. The transceiver requires none of the external image-rejection and intermediate frequency (IF) channel filters by using an LO of 1.6 GHz and the fifth order onchip filters. The chip is fabricated on a $6.5-mm^{2}$ die using a standard $0.25-{\mu}m$ CMOS technology. Experimental results show an in-band image-rejection ratio of 40 dB, an IIP3 of -5 dBm, and a sensitivity of -77 dBm for the Bluetooth mode when the losses from the external components are compensated. It consumes 42 mA in receive ${\pi}/4-diffrential$ quadrature phase-shift keying $({\pi}/4-DQPSK)$ mode of 8 Mb/s, 35 mA in receive GFSK mode of 1 Mb/s, and 32 mA in transmit mode from a 2.5-V supply. These results indicate that the architecture and circuits are adaptable to the implementation of a low-cost, multi-mode, high-speed wireless personal area network.

  • PDF

Wind Energy Interface to Grid with Load Compensation by Diode Clamped Multilevel Inverters

  • Samuel, Paulson;Naik, M. Kishore;Gupta, Rajesh;Chandra, Dinesh
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.271-281
    • /
    • 2014
  • Fluctuating wind conditions necessitate the use of a variable speed wind turbine (VSWT) with a AC/DC/AC converter scheme in order to harvest the maximum power from the wind and to decouple the synchronous generator voltage and frequency from the grid voltage and frequency. In this paper, a combination of a three phase diode bridge rectifier (DBR) and a modified topology of the diode clamped multilevel inverter (DCMLI) has been considered as an AC/DC/AC converter. A control strategy has been proposed for the DCMLI to achieve the objective of grid interface of a wind power system together with local load compensation. A novel fixed frequency current control method is proposed for the DCMLI based on the level shifted multi carrier PWM for achieving the required control objectives with equal and uniform switching frequency operation for better control and thermal management with the modified DCMLI. The condition of the controller gain is derived to ensure the operation of the DCMLI at the fixed frequency of the carrier. The converter current injected into the distribution grid is controlled in accordance with the wind power availability. In addition, load compensation is performed as an added facility in order to free the source currents being fed from the grid of harmonic distortion, unbalance and a low power factor even though the load may be unbalanced, non-linear and of a poor power factor. The results are validated using PSCAD/EMTDC simulation studies.

LVRT Control Strategy of Grid-connected Wind Power System (계통 연계형 풍력 발전 시스템의 LVRT 제어 전략)

  • Shin, Ho-Joon;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.182-190
    • /
    • 2011
  • This paper proposes a LVRT (Low Voltage Ride Through) control strategy which should be satisfied by grid-connected wind power system when grid faults occur. The LVRT regulation indicates rules or actions which have to be executed according to the voltage dip ratio and the fault duration. Especially the wind power system has to support the grid with specified reactive current to secure the grid stability when voltage reduction ratio is over 10%. The LVRT regulation in this paper is based on the German Grid Code and full-scale variable speed wind power conversion system is considered for LVRT control strategy. The proposed LVRT control strategy satisfies not only LVRT regulation but also makes power balance between wind turbine and power system through additional DC link voltage regulation algorithms. Because it is impossible to control grid side power when the 3-phase to ground fault occurs, the DC link voltage is controlled by a generator side inverter using the DC link voltage control strategy. Through the simulation and experiment result, the proposed LVRT control strategy is evaluated and its effectiveness is verified.