• 제목/요약/키워드: Variable conductance

검색결과 53건 처리시간 0.027초

Simulations of Effects of Variable Conductance Throttle Valve on the Characteristics of High Vacuum System

  • Kim, Hyung-Taek;Cho, Han-Ho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.28-35
    • /
    • 2015
  • Thin film electronic devices which brought the current mobile environment could be fabricated only under the high quality vacuum conditions provided by high vacuum systems. Especially for the development of advanced thin film devices, constant high quality vacuum as the deposition pressure is definitely needed. For this purpose, the variable conductance throttle valves were employed to the high vacuum system. In this study, the effects of throttle valve applications on vacuum characteristics were simulated to obtain the optimum design modelling of variable conductance of high vacuum system. Commercial simulator of vacuum system, $VacSim^{(multi)}$, was used on this investigation. Reliability of employed simulator was verified by the simulation of the commercially available models of high vacuum system. Simulated vacuum characteristics of the proposed modelling were agreed with the observed experimental behaviour of real systems. Pressure limit valve and normally on-off control valve were schematized as the modelling of throttle valve for the constant process-pressure of below $10^{-3}torr$. Simulation results were plotted as pump down curve of chamber, variable valve conductance and conductance logic of throttle valve. Simulated behaviors showed the applications of throttle valve sustained the process-pressure constantly, stably, and reliably.

Modified Asymmetrical Variable Step Size Incremental Conductance Maximum Power Point Tracking Method for Photovoltaic Systems

  • Tian, Yong;Xia, Bizhong;Xu, Zhihui;Sun, Wei
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.156-164
    • /
    • 2014
  • The power-voltage (P-V) characteristic of a photovoltaic (PV) array is nonlinear and time varying with the change in atmospheric conditions. As a result, the maximum power point tracking (MPPT) technique must be applied in PV systems to maximize the generated energy. The incremental conductance (INC) algorithm, one of the MPPT strategies, is widely used for its high tracking accuracy, good adaptability to rapidly changing atmospheric conditions, and easy implementation. This paper presents a modified asymmetrical variable step size INC MPPT method that is based on the asymmetrical feature of the P-V curve. Compared with conventional fixed or variable step size method, the proposed method can effectively improve tracking accuracy and speed. The theoretical foundation and design principle of the proposed approach are validated by the simulation and experimental results.

Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas

  • Suh, Jeong-Se;Park, Young-Sik;Chung, Kyung-Taek;Kim, Byoung-Gi
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권4호
    • /
    • pp.125-130
    • /
    • 2006
  • This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with screen meshed wick. The active length of condenser section in a VCHP is varied by non-condensible gas, which controls the operating temperature, and the heat capacity of VCHP is controlled by the operating temperature. In this study, numerical analysis of the VCHP based on the diffusion model of non-condensible gas is done for the thermal control performance of VCHP. Water is used as a working fluid and nitrogen as a control non-condensible gas in the copper tube. As a result, the thermal conductance of VCHP has been compared with that of constant conductance heat pipe (CCHP) corresponding to the variation of operating temperature.

가변 컨덕턴스 히트파이프의 열특성에 관한 해석 (Analysis on the Thermal Characteristics of Variable Conductance Heat Pipe)

  • 김근오;김무근;박병규
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.38-47
    • /
    • 2001
  • The operation characteristics of variable conductance heat pipe(VCHP) were numerically investigated by using 1-dimensional diffuse-front model. For different boundary conditions, the amount of non-condensible gas charge and dimension of gas reservoir were obtained by iterative calculation. It is found that the amount of non-condensible gas charge and dimensions of gas reservoir have an effect on the temperature control of condenser for the given operating condition of VCHP. The numerical results show that VCHP has an excellent capability of temperature control when subjected to a change in the heat input.

  • PDF

가변전열 히이트 파이프의 특성에 관한 연구 (An experimental study on heat transfer characteristics of variable conductance heat pipe)

  • 김주년;이영호;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.4-16
    • /
    • 1984
  • The heat-pipe is characterised by the highly effective thermal conductance. In order to change the thermal conductance, the heat-pipe is connected to a reservior having a space which is filled with non-condensable gas. In normal operation, the vapour of working fluid will tend to pump the non- condensable gas into the reservoir and the gas-vapour interface situates at some point along the condenser section. The thermal conductance is affected by non- condensable gas. It is concluded that the suitable position of interface can be used to control the temperature of condenser section. In this experiment, the evaporating part is connected to the lowest position of heat-pipe. The copper heat-pipe which is filled with Freon-113 or distilled water as working fluid utilized. As results of experimental study, thermal conductance can be increased by the operating pressure which is infulenced by non-condensable gas. A correlative equation between the thermal conductance and the mass of non- condensable gas is also obtained.

  • PDF

Modelling of Optimum Design of High Vacuum System for Plasma Process

  • Kim, Hyung-Taek
    • International journal of advanced smart convergence
    • /
    • 제10권1호
    • /
    • pp.159-165
    • /
    • 2021
  • Electronic devices used in the mobile environments fabricated under the plasma conditions in high vacuum system. Especially for the development of advanced electronic devices, high quality plasma as the process conditions are required. For this purpose, the variable conductance throttle valves for controllable plasma employed to the high vacuum system. In this study, we analyzed the effects of throttle valve applications on vacuum characteristics simulated to obtain the optimum design modelling for plasma conditions of high vacuum system. We used commercial simulator of vacuum system, VacSim(multi) on this study. Reliability of simulator verified by simulation of the commercially available models of high vacuum system. Simulated vacuum characteristics of the proposed modelling agreed with the observed experimental behaviour of real systems. Pressure limit valve and normally on-off control valve schematized as the modelling of throttle valve for the constant process-pressure of below 10-3 torr. Simulation results plotted as pump down curve of chamber, variable valve conductance and conductance logic of throttle valve. Simulated behaviors showed the applications of throttle valve sustained the process-pressure constantly, stably, and reliably in plasma process.

VCHP에서 불응축 가스량이 열전달 성능에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the affect of Non-condensable Gas Quantity on the Heat Transfer Performances in a Variable Conductance Heat Pipe)

  • 박기호;이기우;이욱현;이계중;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.19-24
    • /
    • 2003
  • This paper is to research the heat transfer characteristic in copper-water variable conductance heat pipes(VCHP) with a non-condensable gas and gas reservoir. The heat transfer characteristics in the VCHP have not yet been studied much researches. VCHP are used in many applications. These applications range from thermal control of components and systems on satellites, to precise temperature calibration duties, conventional electronics temperature control and thermal diodes. The practical use of VCHP is a simple way to control the temperature of satellites. As the quantity of NCG was increased, there was an increase in the saturation vapor temperatures. As the input heat has loaded from 90 W to 110 W, the difference of the evaporator surface is lower than $10^{\circ}C$.

  • PDF

수동 소자를 사용하지 않는 가변 이득 증폭기 설계 (Design of Variable Gain Amplifier without Passive Devices)

  • 조종민;임신일
    • 한국산업정보학회논문지
    • /
    • 제18권5호
    • /
    • pp.1-8
    • /
    • 2013
  • 본 논문은 수동소자를 사용하지 않고 선형성 향상을 얻는 가변이득증폭기(VGA, variable gain amplifier) 설계에 관련된 것이다. 이 제안된 VGA는 전류 귀환 증폭기 구조를 이용하고, 이득은 입력단과 귀환부의 트랜스컨덕턴스(GM) 비로 얻어진다. 선형성과 높은 이득을 얻기 위하여 귀환 트랜스컨덕턴스에 전류 분할 기법과 소스 축퇴(degeneration) 기법을 사용하였다. 이득의 변화는 가변 정류기로 입력 트랜스컨덕턴스의 바이어스 전류를 변화시켜 얻을 수 있다. 이 VGA는 $0.35{\mu}m$ CMOS공정을 사용하여 설계하였고, 저 전력을 위해 sub-threshold 영역에서 동작시키게 하였다. 가변 이득은 23dB~43dB의 결과를 얻도록 하였고, 소모 전류는 3.3V에서 $2.82{\mu}A{\sim}3{\mu}A$ 이다. 이 VGA가 차지하는 칩 면적은 $120{\mu}m{\times}100{\mu}m$이다.

불응축가스 주입량에 따른 VCHP의 열제어 특성 (Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas)

  • 서정세;박영식;정경택
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1139-1144
    • /
    • 2005
  • This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with meshed wick. The length of condenser portion in a VCHP is varied by the expansion of inert gas with the operation temperature, and the heat transport capacity is thus varied with the operating temperature. In this study, numerical evaluation of the VCHP is made for the thermal performance of VCHP, based on the diffusion model of inert gas. Water is used as a working fluid and nitrogen as a control inert gas in the copper tube. As a result, the thermal performance of VCHP has been compared with that of constant conductance heat pipe (CCHP) according to the variation of operation temperature. Maximum heat transport capacity of VCHP is mainly presented for operation temperature and the variation of operation temperature is also presented for heat transfer rate of VCHP.

가변열전도성능 히트파이프(VCHP)의 온도제어 성능에 관한 실험 (An Experimental Study on the Temperature-Control Performance of a Variable Conductance Heat Pipe)

  • 부준홍;박철민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2124-2129
    • /
    • 2007
  • A VCHP was fabricated and tested for its thermal performance. The container was made of copper, and the working fluid was water. STS-316 screen of mesh number 100 was inserted as a capillary structure. As a baseline performance, a normal heat pipe of the same dimensions was tested in advance to compare with VCHP, where an inert gas container was attached. The outer diameter of the heat pipe was 12.8 mm and the total length was 600 mm. The evaporator and the condenser lengths were both 200 mm. The thermal load ranged from 20 to 300W. Typical result revealed that the operating temperature of the VCHP stayed almost constant, while that of the normal heat pipe varied as much as 40$^{\circ}C$. Therefore, it was demonstrated that the VCHP is very effective for temperature control of heat-dissipating devices.

  • PDF