VCHP에서 불응축 가스량이 열전달 성능에 미치는 영향에 관한 실험적 연구

An Experimental Study on the affect of Non-condensable Gas Quantity on the Heat Transfer Performances in a Variable Conductance Heat Pipe

  • 박기호 (한국에너지기술연구원 미활용에너지연구센터) ;
  • 이기우 (한국에너지기술연구원 미활용에너지연구센터) ;
  • 이욱현 (한국에너지기술연구원 미활용에너지연구센터) ;
  • 이계중 (한국에너지기술연구원 미활용에너지연구센터) ;
  • 서정세 (경상대학교 기계항공공학부)
  • 발행 : 2003.11.05

초록

This paper is to research the heat transfer characteristic in copper-water variable conductance heat pipes(VCHP) with a non-condensable gas and gas reservoir. The heat transfer characteristics in the VCHP have not yet been studied much researches. VCHP are used in many applications. These applications range from thermal control of components and systems on satellites, to precise temperature calibration duties, conventional electronics temperature control and thermal diodes. The practical use of VCHP is a simple way to control the temperature of satellites. As the quantity of NCG was increased, there was an increase in the saturation vapor temperatures. As the input heat has loaded from 90 W to 110 W, the difference of the evaporator surface is lower than $10^{\circ}C$.

키워드