Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas

  • Suh, Jeong-Se (School of Mechanical & Aerospace Engineering, GyeongSang National University) ;
  • Park, Young-Sik (Department of Car-Electronics, Korea Polytechnic VII College) ;
  • Chung, Kyung-Taek (School of Mechanical & Aerospace Engineering, GyeongSang National University) ;
  • Kim, Byoung-Gi (School of Mechanical & Aerospace Engineering, GyeongSang National University)
  • 발행 : 2006.12.10

초록

This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with screen meshed wick. The active length of condenser section in a VCHP is varied by non-condensible gas, which controls the operating temperature, and the heat capacity of VCHP is controlled by the operating temperature. In this study, numerical analysis of the VCHP based on the diffusion model of non-condensible gas is done for the thermal control performance of VCHP. Water is used as a working fluid and nitrogen as a control non-condensible gas in the copper tube. As a result, the thermal conductance of VCHP has been compared with that of constant conductance heat pipe (CCHP) corresponding to the variation of operating temperature.

키워드

참고문헌

  1. Gaugler, K. S., 1942, Heat Transfer Device. US patent. 2350348 April. 21 Dec. Published 6 June, 1944
  2. Marcus, B. D., 1971, Theory and design of variable conductance heat pipe: Control techniques, 2nd report by TRW Inc. to NASA, Contact No. NAS2-5503
  3. Chi, S. W., 1976, Heat Pipe Theory and Practice, McGraw-Hill, New York
  4. Bobeo, R. P., 1989, Variable conductance heat pipe performance analysis, Journal of Thermophysics, Vol. 3, No.1, pp.33-41 https://doi.org/10.2514/3.122
  5. Kobayashi, Y., Okumura, A. and Matsue, T., 1991, Effect of gravity and non condensable gas levels on condensation in variable conductance heat pipe, Journal of Thermophysics, Vol. 5, Vo. 1, pp, 61-68 https://doi.org/10.2514/3.227
  6. Sauciuc, I., Akbarzadeh, A. and Johnson, P., 1996, Temperature control using variable conductance closed two-phase heat pipe, Heat Mass Transfer, Vol. 23, No.3, pp.427-433 https://doi.org/10.1016/0735-1933(96)00028-0
  7. Peterson, P. F. and Tien, C. L., 1990, Mixed double-diffusive convection in gas-loaded heat pipes, Journal of Heat Transfer, Vol. 112, pp. 78-83 https://doi.org/10.1115/1.2910368
  8. Park, Y. S., Jung, K. T. and Suh, J. S., 2003, Influence of heat load and operation temperature on the thermal performance of a water-copper variable conductance heat pipe with screen mesh wick, Proceedings of the KSME 2003, Fall Annual Meeting, pp.9-14