• Title/Summary/Keyword: Variable Ultrasound

Search Result 53, Processing Time 0.025 seconds

Preoperative Evaluation of the Facial Artery Using Facial Angio Computed Tomography (전산화단층촬영 혈관조영술을 이용한 얼굴동맥의 수술 전 평가)

  • Kim, Joo-Hak;Kang, Nak-Heon;Lee, In-Ho;Seo, Young-Joon;Yang, Ho-Jik;Song, Seung-Han;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.719-724
    • /
    • 2011
  • Purpose: Previous studies of the facial artery have shown significant anatomical variability in this region. The vascular anatomy of the region is considered unreliable in predicting the ideal pedicle. Preoperative imaging has been suggested as a means of improving preoperative awareness, with Doppler ultrasound as useful tools. Multi-detector row angiographic computed tomography (angio CT) is a significant improvement, providing noninvasive operator-independent details of the vascular anatomy. This tool was used to perform an $in$ $vivo$ anatomical study of the facial artery, demonstrating the usefulness of facial angio CT in planning the facial reconstruction. Methods: Eleven consecutive patients underwent facial angio CT of the facial vasculature with the anatomical details of the facial artery assessed. Results: Facial angio CT could demonstrate the size and course of the facial vasculature, particularly the facial artery. Conclusion: The vascular anatomy of the facial artery is highly variable, and thus there is a role for preoperative imaging. Facial angio CT can demonstrate cases where there is an aberrant or non-preferred anatomy, or select the method of a facial reconstruction.

Effects of Heart Fatty Acid-binding Protein Genotype on Intramuscular Fat Content in Duroc Pigs Selected for Meat Production and Meat Quality Traits

  • Uemoto, Yoshinobu;Suzuki, Keiichi;Kobayashi, Eiji;Sato, Syushi;Shibata, Tomoya;Kadowaki, Hiroshi;Nishida, Akira
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.5
    • /
    • pp.622-626
    • /
    • 2007
  • Using multi-trait animal model BLUP, selection was conducted over seven generations for growth rate (DG), real-time ultrasound loin-eye muscle area (LEA), backfat thickness (BF), and intramuscular fat content (IMF) to develop a new line of purebred Duroc pigs with enhanced meat production and meat quality. This study was intended to investigate the relationship between restriction fragment length polymorphism (RFLP) of a heart fatty acid-binding protein (H-FABP) gene and intramuscular fat content (IMF) of this Duroc purebred population. The present experiment examined the RFLP of 499 slaughtered pigs. The DNA was separated from the blood or ear tissue of the pigs, which were slaughtered at 105 kg of body weight. Intramuscular fat content of the longissimus muscle was measured using chemical analysis. A significant difference was detected in the breeding value of IMF among the H-FABP PCR RFLP genotypes. The AA genotype has a significantly larger positive effect on the IMF breeding value than do the Aa and aa genotypes for the MspI RFLP. In addition, the DD genotype has a significantly greater positive effect on IMF breeding value than the Dd and dd genotypes for the HaeIII RFLP. For the HinfI RFLP, the hh genotype has a significantly larger positive effect on IMF breeding value than the HH genotype. Multiple regression analysis was performed using the IMF breeding values as the dependent variable and the three H-FABP genotypes as independent variables. Results revealed that the contribution of the genotypes to variation in IMF breeding values was approximately 40%. These results demonstrated that H-FABP RFLPs affect IMF in this Duroc population.

Primary Splenic Paraganglioma in a Dog

  • An, Su-Jin;Moon, Jong-Hyun;Hwang, Tae-Sung;Lee, Hee-Chun;Yu, Do-Hyeon;Sur, Jung-Hyang;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.35 no.4
    • /
    • pp.155-160
    • /
    • 2018
  • A 6-year-old intact female Shih-tzu dog was referred due to anorexia. Physical examination, complete blood count, serum chemical analysis, radiography, and ultrasonography were evaluated. Physical examination and hematological analysis showed normal findings. Abdominal radiographs and ultrasound revealed well-defined masses in the spleen. Other abdominal organs showed no significant abnormalities. Tissue samples taken via sono-guided fine needle aspiration of the splenic mass showed many bare nuclei, which were variable in size. Results of histopathological and immunohistochemical (IHC) analyses performed after splenectomy were consistent with paraganglioma. Based on these findings, we diagnosed this patient with a paraganglioma of splenic origin. Two months after splenectomy, abdominal ultrasonography revealed a new neoplastic lesion in the liver. The clients refused further management and the patient expired three months after initial diagnosis. Necropsy as well as histopathological and IHC examinations of other systemic organs including the liver, adrenal gland, kidney, brain, urinary bladder, lung, aortic body, carotid body, and pancreas were performed. The neoplastic tissue in the liver also demonstrated features of a paraganglioma, and there were no remarkable findings in all other organs.

Optimization of ultrasonic-assisted enzymatic hydrolysis conditions for the production of antioxidant hydrolysates from porcine liver by using response surface methodology

  • Yu, Hui-Chuan;Tan, Fa-Jui
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.11
    • /
    • pp.1612-1619
    • /
    • 2017
  • Objective: The objective of this study was to optimize ultrasonic-assisted enzymatic hydrolysis conditions, including enzyme-to-substrate (E/S) ratio, pH, and temperature, for producing porcine liver hydrolysates (PLHs) with the highest 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical scavenging activity by using response surface methodology (RSM). Methods: The study used RSM to determine the combination of hydrolysis parameters that maximized the antioxidant activity of our PLHs. Temperature ($40^{\circ}C$, $54^{\circ}C$, and $68^{\circ}C$), pH (8.5, 9.5, and 10.5), and E/S ratio (0.1%, 2.1%, and 4.1%) were selected as the independent variables and analyzed according to the preliminary experiment results, whereas DPPH free radical scavenging activity was selected as the dependent variable. Results: Analysis of variance showed that E/S ratio, pH, and temperature significantly affected the hydrolysis process (p<0.01). The optimal conditions for producing PLHs with the highest scavenging activity were as follows: E/S ratio, 1.4% (v/w); temperature, $55.5^{\circ}C$; and initial pH, 10.15. Under these conditions, the degree of hydrolysis, DPPH free radical scavenging activity, ferrous ion chelating ability, and reducing power of PLHs were 24.12%, 79%, 98.18%, and 0.601 absorbance unit, respectively. The molecular weight of most PLHs produced under these optimal conditions was less than 5,400 Da and contained 45.7% hydrophobic amino acids. Conclusion: Ultrasonic-assisted enzymatic hydrolysis can be applied to obtain favorable antioxidant hydrolysates from porcine liver with potential applications in food products for preventing lipid oxidation.

Ultrasonic Cavitation Effect Observation Using Bubble Cloud Image Analysis (기포군 영상분석을 통한 초음파 캐비테이션 현상의 변화 관찰)

  • Noh, Si-Cheol;Kim, Ju-Young;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.124-130
    • /
    • 2011
  • In this study, in order to evaluate the yield of bubble by ultrasonic cavitation in HIFU sonication, the bubble image analysis was performed. The changing phenomenon of cavitation effect according to the sonication condition was discussed by analyzing the bubble image. Especially the appearance of bubble cloud, the size of micro-bubble, and the yield of bubble were considered. The 500 KHz and 1.1 MHz concave type ultrasonic transducers were used for HIFU sonication. Computer controlled digital camera was used to obtain the bubble image, and the binary image processing(binarization coefficient : 0.15) was performed to analyze them. In results of 500 KHz and 1.1 MHz transducer, the area of bubble cloud was increased in proportion to the rise in sonication intensity($R^2$ : 0.7031 and 0.811). The mean size of single microbubble was measured as 98.18 um in 500 KHz sonication, and 63.38 um in 1.1 MHz sonication. In addition, the amount of produced bubble was increased in proportion to sonication intensity. Through the result of this study and further study for variable image processing method, the quantitative evaluation of ultrasonic cavitation effects in HIFU operation could be possible with the linearity associated with the sonication conditions.

Compare correlation differnces in blood in blood flow velocity parameters and blood flow velocity the radial artery and a piece of paper as a maker (요골동맥과 첨지를 이용하여 혈류속도 파라미터와 혈류속도 사이의 상관관계 비교)

  • Heo, Sun-Oh;Jeong, Jin-Hyeong;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.2
    • /
    • pp.187-193
    • /
    • 2015
  • In this study, regressive models were employed to predict the blood velocity by using independent variables which measured by 3 sensors, such as electrocardiogram (ECG), photo-plethysmogram (PPG), pulse diagnosis sensor, without ultrasound device at high cost. In experiment, the high predictable model was induced to estimate the blood velocity correctly by comparing correlation values and significance probabilities between independent variables and blood velocities. Results showed that the model induced by two or three independent variables had a higher predictability than those by a single independent variable.

Usefulness of Cerebellar Transverse Diameter and Abdominal Circumference Ratio in Fetal Growth Evaluation (태아성장평가에서 소뇌횡직경과 복부둘레비의 유용성)

  • Yang, Sung-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.649-656
    • /
    • 2021
  • The purpose of this study was to evaluate the appropriateness of transverse cerebellar diameter and abdominal circumference (TCD/AC ratio) as variables to evaluate intrauterine growth restriction of the fetus. From April 2019 to March 2021, 784 pregnant women who underwent ultrasound as a regular checkup at I hospital were retrospectively analyzed using the transverse cerebellar diameter and abdominal circumference measurements. In simple regression analysis, transverse cerebellar diameter and abdominal circumference had an effect of 97.2% and 97.5% on gestational age (p<0.001). In addition, the percentile of the TCD/AC ratio for each gestational age group was calculated through frequency analysis, and the 95th percentile of intrauterine growth restriction prediction was 14.2. As a result, it is thought that the TCD/AC ratio can be used as a useful variable to evaluate the normal growth of the fetus and predict the IUGR.

Comparative evaluation of ultrasonography with clinical respiratory score in diagnosis and prognosis of respiratory diseases in weaned dairy buffalo and cattle calves

  • Hussein, Hussein Awad;Binici, Cagri;Staufenbiel, Rudolf
    • Journal of Animal Science and Technology
    • /
    • v.60 no.12
    • /
    • pp.29.1-29.11
    • /
    • 2018
  • Background: Respiratory troubles have economic impacts in countries where livestock industry is an important segment of the agricultural sector, as well as these problems may cause significant economic losses for bovine producers. Various practical methods are used to assess diseases that affect the bovine respiratory system. Ultrasonography is a noninvasive tool that has been used frequently in diagnosis of various animal diseases. The present study was designed to establish whether thoracic ultrasonography is a diagnostic tool for detection of respiratory troubles in weaned buffalo and cattle calves, as well as to assess its prognostic value in comparison with clinical respiratory scores. Thirty five (15 buffalo and 20 cattle) calves were included. Twelve (6 buffalo and 6 cattle) clinically healthy calves were enrolled as controls. Results: Based on physical examinations, clinical respiratory scores (CRS), ultrasound lung scores (ULS) and postmortem findings, animals were classified into 4 groups as pulmonary emphysema (n = 8), interstitial pulmonary syndrome (n = 7), bronchopneumonia (n = 12), and pleurisy (n = 8). The mean values of CRS and ULS were significantly higher in diseased calves (P < 0.01). In calves with pulmonary emphysema and interstitial syndrome, thoracic ultrasonography revealed numerous comet-tail artifacts, which varied in numbers and imaging features. Furthermore, variable degrees of pulmonary consolidation with alveolograms and bronchograms were noticed in bronchopneumonic calves. In addition, thick irregular or fragmented pleura with pleural effusions and fibrin shreds were imaged in calves with pleurisy. A weak correlation was calculated between CRS and ULS (r = 0.55, P < 0.01). Hematologically, the counts of white blood cells, activities of aspartate aminotransferase and partial tensions of carbon dioxide were significantly increased in all diseased groups. Serum concentrations of total globulins were higher in claves with bronchopneumonia (P < 0.05). The partial tension of oxygen was decreased in all diseased calves (P < 0.05). Conclusions: Thoracic ultrasonography is a diagnostic tool for various lung troubles and assessment the grade and severity of pulmonary diseases, as well as it can be used as a follow-up tool for evaluating the prognosis of respiratory troubles and monitoring the efficacy of therapies.

Effects of Muscle Thickness of Masseter and Sternocleidomastoid, Forward Head Posture and Breathing in Subjects With and Without Dentures

  • Kim, Se-Yeon;Kim, Ki-Song;Hwang, Young-In
    • Physical Therapy Korea
    • /
    • v.29 no.4
    • /
    • pp.255-261
    • /
    • 2022
  • Background: For the elderly, masticatory function is one of the most important oral functions and the masticatory ability is related to the wearing of dentures. Many older people wear dentures for their masticatory function, but a significant number of older people who use dentures have found that they feel uncomfortable when performing their daily activities, such as performing masticating functions or talking. Objects: The purpose of this study is to investigate how the forward head posture (FHP), respiratory function and thickness of masseter (MS), and sternocleidomastoid (SCM) are affected by the presence or absence of dentures in the elderly, and what kind of correlation there is between these variables. Methods: The study was conducted on 11 patients in the normal group and 13 in the denture group. The participant's cognitive ability was evaluated using Mini-Mental State Examination Korean (MMSE-K), and the FHP was evaluated by measuring the craniovertebral angle (CVA). The thickness of the MS and SCM muscles were measured using ultrasound, and respiration was measured with a spirometry. As for the statistical method, the correlation of each variable was investigated using Spearman's correlation coefficient. Results: In the normal group, there was a significant correlation between forced vital capacity (FVC) and forced expiratory volume in 1 second (FEV1) (p < 0.001), and in the denture group, FVC and FEV1 (p < 0.001), maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) (p < 0.001), CVA and Lt. MS (p = 0.012). Conclusion: CVA and Lt. MS of the denture group have a high negative correlation, it is related that the thickness of MS may be thick when the elderly wearing dentures are FHP.

Should Korean Medicine doctors use modern diagnostic medical devices? Survey result of public perspectives (국민인식을 기초로 한의사의 현대 진단의료기기 사용 법제화 필요성에 대한 제언 : 설문조사를 중심으로)

  • Juchul Kim;Byoungcheun Hwang;Manki Hwang;Seungmin Kathy Lee;EunHee Yi;Jungtae Leem
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.94-105
    • /
    • 2022
  • Objectives: This study investigated public opinion on the use of modern diagnostic medical devices by Korean Medicine doctors. Methods: A questionnaire looking into perceptions on the use of modern medical devices was developed. It was distributed by a third party and data was collected. Results were analyzed through frequency analysis, chi-square analysis (χ2-test), frequency and cross analysis using R program. The measurement variable in the study was the respondent's perspectives and expectations on the use of modern diagnostic medical devices by Korean Medicine doctors. The maximum significance level was 0.05. Results: There were a total of 3,000 responses and 80.8% of the respondents replied that there is a need for government-level discussion on endowing rights to Korean Medicine doctors as supervisors for safety management of radiation generating devices. Also, 83.3% of the respondents agreed the use of ultrasound imaging equipment in Korean Medicine clinics should be legalized. Conclusions: According to this study, respondents strongly support the use of modern diagnostic medical devices by Korean Medicine doctors. This is the first study to investigate public opinion in this area and it provides a significant insight into the public needs and desires for a wider scope of practice for Korean Medicine in the healthcare system.