• Title/Summary/Keyword: Variable Sampling Rate

Search Result 90, Processing Time 0.027 seconds

Time-Balanced Quota Sampling for Telephone Survey (전화조사를 위한 시간균형할당표본추출)

  • Huh, Myung-Hoe;Hwang, Jin-Mo
    • Survey Research
    • /
    • v.7 no.2
    • /
    • pp.39-52
    • /
    • 2006
  • Most of Korean survey institutions adopt quota sampling for telephone surveys based on region, gender and age-band. In weekdays, it is well blown that there exist substantial differences in day time in-house rate by individual's socio-demographic attributes. So, quota sampling may induce systematic respondent selection bias. To solve the problem, we propose "time-balanced quota sampling" in which interviewer's call time-band is added as an quota variable. Furthermore, we propose "time-balanced quasi-quota sampling" which is derived by partially relaxing evening time quotas in time-balanced quota sampling. We compare the conventional and the newly proposed quota sampling schemes by drawing Monte Carlo samples from the hypothetical population for which the Korea 2004 time use survey data is assumed.

  • PDF

Multivariate EWMA Control Chart for Means of Multiple Quality Variableswith Two Sampling Intervals

  • Chang, Duk-Joon;Heo, Sunyeong
    • Journal of Integrative Natural Science
    • /
    • v.5 no.3
    • /
    • pp.151-156
    • /
    • 2012
  • Because of the equivalence between control chart procedures and hypothesis testing, we propose to use likelihood ratio test (LRT) statistic $Z_i^2$ as the multivariate control statistic for simultaneous monitoring means of the multivariate normal process. Properties and comparisons of the proposed control charts are explored and conducted for matched fixed sampling interval (FSI) and variable sampling interval (VSI) with two sampling interval charts. The result of numerical comparisons shows that EWMA chart with two sampling interval procedure is more efficient than the corresponding FSI chart for small or moderate changes. When large shift of the process has occurred, we also found that Shewhart chart is more efficient than EWMA chart.

A Comparison of Average Time Rate with range and variance chart when using variable sampling interval (변량표본추출간격을 이용한 범위관리도와 분산관리도의 ATS비교)

  • 이희춘;지선수
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.17 no.30
    • /
    • pp.101-106
    • /
    • 1994
  • The basic of the VSI charts is that if the sample statistic computed after a sample is taken shows some indication of a process change than the sampling interval before the next sample should be short otherwise long. This paper was shown the VSS chart can be considerably more efficient than the FSS chart and the effectiveness of VSI R chart with S chart used for monitoring a process standard deviation.

  • PDF

Map-based Variable Rate Application of Nitrogen Using a Multi-Spectral Image Sensor (멀티스펙트랄 이미지 센서를 이용한 전자 지도 기반 변량 질소 살포)

  • Noh, Hyun-Kwon;Zhang, Qin
    • Journal of Biosystems Engineering
    • /
    • v.35 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • Site-specific N application for corn is one of the precision crop management. To implement the site-specific N application, various nitrogen stress sensing methods, including aerial image, tissue analysis, soil sampling analysis, and SPAD meter readings, have been used. Use of side-dressing, an efficient nitrogen application method than a uniform application in either late fall or early spring, relies mainly on the capability of nitrogen deficiency detection. This paper presents map-based variable rate nitrogen application based using a multi-spectral corn nitrogen deficiency(CND) sensor. This sensor assess the nitrogen stress by means of the estimated SPAD reading calculated from the corn leave reflectance. The estimated SPAD value from the CND sensor system and location information form DGPS of each field block was combined into the field map using a ArcView program. Then this map was converted into a raster file for a map-based variable rate application software. The relative SPAD (RSPAD = SPAD over reference SPAD) was investigated 2 weeks after the treatments. The results showed that the map-based variable rate application system was feasible.

Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold (가변 진폭 임계값을 이용한 걸음수 검출 정확도 향상 기법)

  • Ryu, Uk Jae;Kim, En Tae;An, Kyung Ho;Chang, Yun Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.6
    • /
    • pp.257-264
    • /
    • 2013
  • In this study, we have designed the variable amplitude threshold algorithm that can enhance the accuracy of step count using variable amplitude. This algorithm converts the x, y, z sensor values into a single energy value($E_t$) by using SVM(Signal Vector Magnitude) algorithm and can pick step count out over 99% of accuracy through the peak data detection algorithm and fixed peak threshold. To prove the results, We made the noise filtering with the fixed amplitude threshold from the amplitude of energy value that found out the detection error was increasing, and it's the key idea of the variable amplitude threshold that can be adapted on the continuous data evaluation. The experiment results shows that the variable amplitude threshold algorithm can improve the average step count accuracy up to 98.9% at 10 Hz sampling rate and 99.6% at 20Hz sampling rate.

Optimal Design of c Control Chart using Variable Sampling Interval (가변추출간격을 이용한 c 관리도의 최적설계)

  • Park, Joo-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.2
    • /
    • pp.215-233
    • /
    • 2007
  • Even though the ad hoc Shewhart methods remain controversial due to various mathematical flaws, there is little disagreement among researchers and practitioners when a set of process data has a skewness distribution. In the context and language of process control, the error related to the process data shows that time to signal increases when a control parameter shifts to a skewness direction. In real-world industrial settings, however, quality practitioners often need to consider a skewness distribution. To address this situation, we developed an enhanced design method to utilize advantages of the traditional attribute control chart and to overcome its associated shortcomings. The proposed design method minimizes bias, i.e., an average time to signal for the shift of process from the target value (ATS) curve, as well as it applies a variable sampling interval (VSI) method to an attribute control chart for detecting a process shift efficiently. The results of the factorial experiment obtained by various parameter circumstances show that the VSI c control chart using nearly unbiased ATS design provides the smallest decreasing rate in ATS among other charts for all experimental cases.

A Nonuniform Sampling Technique and Its Application to Speech Coding (비균등 표본화 기법과 음성 부호화로의 응용)

  • Iem, Byeong-Gwan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.1
    • /
    • pp.28-32
    • /
    • 2014
  • For a signal such as speech showing piece-wise linear shape in a very short time period, a nonuniform sampling method based on the inflection point detection (IPD) is proposed to reduce data rate. The method exploits the geometrical characteristics of signal further than the existing local maxima/minima detection (MMD) based sampling method. As results, the reconstructed signal by the interpolation of the IPD based sampled data resembles the original speech more. Computer simulation shows that the proposed IPD based method produces about 9~23 dB improvement over the existing MMD method. To show the usefulness of the IPD technique, it is applied to speech coding, and compared to the continuously variable slope delta modulation (CVSD). The nonuniformly sampled data is binary coded with one bit flag set "1". Noninflection samples are not sent, but only flag bits set 0 are sent. The method shows 0.3 ~ 9 dB SNR and 0.5 ~ 1.3 mean opinion score (MOS) improvements over the CVSD.

Determination of Variable Rate Fertilizing Amount in Small Size Fields Using Geographic Information System

  • S. I. Cho;I. S. Kang;Park, S. H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.236-245
    • /
    • 2000
  • The feasibility of precision farming for small sized fields was studied by determining fertilizing amount of nitrogenous and calcareous to a cite specific region. A detailed soil survey at three experimental fields of 672㎡, 300㎡ and 140㎡ revealed a considerable spatial variation of the pH and organic matter(OM) levels. Soil organic matter was measured using Walkley-Black method and soil pH was measured with a pH sensor. Soil sample was obtained by Grid Node Sampling Method. The soil sampling depth was 10 - 20 cm from the soil surface. To display soil nutrient variation, a soil map was made using Geographic Information System (GIS) software. In soil mapping, soil data between nodes was interpolated using Inverse Distance Weighting (IDW) method. The variation was about 1 - 1.8 in pH value and 1.4 -7 % in OM content. Fertilizing Amount of nitrogenous and calcareous was determined by the fertilizing equation which was proposed by National Institute of Agricultural Science and Technology.(NIAST). The variation of fertilizing amount was about 3 - 11 kg/10a in nitrogenous and 70 - 140 kg/10a in calcareous. The results showed a feasibility of precision fertilizing for small size fields.

  • PDF

Determination of Variable Rate Fertilizing Amount in Small Size Fields for Precision Fertilizing (정밀 시비를 위한 소구획 경작지내의 가변적 시비처리량 결정)

  • 조성인;강인성;최상현
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.241-250
    • /
    • 2000
  • The feasibility of precision fertilizing for small size fields was studied by determining fertilizing amount of nitrogenous and calcareous to a cite specific region. A detailed soil survey at three experimental fields of $672m^2$, $300m^2$ and $140m^2$ revealed a considerable spatial variation of the pH and organic matter(OM) levels. Soil organic matter was measured using Walkley-Black method and soil pH was measured with a pH sensor. Soil sample was obtained by Grid Node Sampling Method. The soil sampling depth was 10∼20 cm from the soil surface. To display soil nutrient variation, a soil map was made using Geographic Information System (GIS) software. In soil mapping, soil data between nodes was interpolated using Inverse Distance Weighting (IDW) method. The variation was about 1∼1.8 in pH value and 1.4∼7% in OM content. Fertilizing Amount of nitrogenous and calcareous was determined by th fertilizing equation which was proposed by National Institute of Agricultural Science and Technology(NIAST). The variation of fertilizing amount was about 3∼11 kg/10a in nitrogenous and 70∼140 kg/10a in calcareous. The results showed a feasibility of precision fertilizing for small size fields.

  • PDF

Accelerated Life Tests under Gamma Stress Distribution (스트레스함수가 감마분포인 가속수명시험)

  • 원영철
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.3
    • /
    • pp.59-66
    • /
    • 2002
  • This paper presents accelerated life tests for Type I censoring data under probabilistic stresses. Probabilistic stress, S, is the random variable for stress influenced by test environments, test equipments, sampling devices and use conditions. The hazard rate, $\theta$ is a random variable of environments and a function of probabilistic stress. In detail, it is assumed that the hazard rate is linear function of the stress, the general stress distribution is a gamma distribution and the life distribution for the given hazard rate, $\theta$is an exponential distribution. Maximum likelihood estimators of model parameters are obtained, and the mean life in use stress condition is estimated. A hypothetical example is given to show its applicability.