• 제목/요약/키워드: Variable Resistance

검색결과 475건 처리시간 0.029초

가변저항이 없는 고정밀 Programmable T/C 신호변환기의 구현 (Implementation of High Precision Programmable T/C Signal Coverter Without Variable-Resistance)

  • 이성희;이진희;박태준;목임수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.423-425
    • /
    • 1998
  • In this paper, a novel Programmable Signal Conditioner(PSC) for Thermo Couple(T/C) without variable-resistance is proposed. It is fabricated by using a fully digitalized error-correction and calibration algorithm. In signal processing of T/C, since the output voltage of T/C is nonlinear and its level is very low, the circuitry become very complicated to reduce the converting error and identify the true thermal voltage signal. The newly proposed PSC has compensation and calibration algorithm not using variable resistor. Moreover structure can be very simple and it has highly precise output characteristics.

  • PDF

중력 법칙을 이용한 전자나침반의 경사오차 및 비 수평오차 보정 (Inclination and Non-horizontal Error Correction of Magnetic Compass by the Law of Gravity)

  • 박계도;이장명
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.606-611
    • /
    • 2011
  • This paper proposes a correction method concerning the inclination error and non-horizontal error of magnetic compass when magnetic compass is vibrated. This system used the 2-axis variable resistance and pendulum. A pendulum hanging from the 2-axis variable resistance of this system is always maintain the horizontal because of gravity. but these data had some intrinsic error. So we used the low pass filter to solve this problem. So this system can get the accurate azimuth of magnetic compass. In conclusion, These results demonstrate convincingly by applied algorithm of experiment.

ERP 도입 전 구성원의 저항 (A Study on Users' Resistance toward ERP in the Pre-adoption Context)

  • 박재성;조용수;고준
    • Asia pacific journal of information systems
    • /
    • 제19권4호
    • /
    • pp.77-100
    • /
    • 2009
  • Information Systems (IS) is an essential tool for any organizations. The last decade has seen an increasing body of knowledge on IS usage. Yet, IS often fails because of its misuse or non-use. In general, decisions regarding the selection of a system, which involve the evaluation of many IS vendors and an enormous initial investment, are made not through the consensus of employees but through the top-down decision making by top managers. In situations where the selected system does not satisfy the needs of the employees, the forced use of the selected IS will only result in their resistance to it. Many organizations have been either integrating dispersed legacy systems such as archipelago or adopting a new ERP (Enterprise Resource Planning) system to enhance employee efficiency. This study examines user resistance prior to the adoption of the selected IS or ERP system. As such, this study identifies the importance of managing organizational resistance that may appear in the pre-adoption context of an integrated IS or ERP system, explores key factors influencing user resistance, and investigates how prior experience with other integrated IS or ERP systems may change the relationship between the affecting factors and user resistance. This study focuses on organizational members' resistance and the affecting factors in the pre-adoption context of an integrated IS or ERP system rather than in the context of an ERP adoption itself or ERP post-adoption. Based on prior literature, this study proposes a research model that considers six key variables, including perceived benefit, system complexity, fitness with existing tasks, attitude toward change, the psychological reactance trait, and perceived IT competence. They are considered as independent variables affecting user resistance toward an integrated IS or ERP system. This study also introduces the concept of prior experience (i.e., whether a user has prior experience with an integrated IS or ERP system) as a moderating variable to examine the impact of perceived benefit and attitude toward change in user resistance. As such, we propose eight hypotheses with respect to the model. For the empirical validation of the hypotheses, we developed relevant instruments for each research variable based on prior literature and surveyed 95 professional researchers and the administrative staff of the Korea Photonics Technology Institute (KOPTI). We examined the organizational characteristics of KOPTI, the reasons behind their adoption of an ERP system, process changes caused by the introduction of the system, and employees' resistance/attitude toward the system at the time of the introduction. The results of the multiple regression analysis suggest that, among the six variables, perceived benefit, complexity, attitude toward change, and the psychological reactance trait significantly influence user resistance. These results further suggest that top management should manage the psychological states of their employees in order to minimize their resistance to the forced IS, even in the new system pre-adoption context. In addition, the moderating variable-prior experience was found to change the strength of the relationship between attitude toward change and system resistance. That is, the effect of attitude toward change in user resistance was significantly stronger in those with prior experience than those with no prior experience. This result implies that those with prior experience should be identified and provided with some type of attitude training or change management programs to minimize their resistance to the adoption of a system. This study contributes to the IS field by providing practical implications for IS practitioners. This study identifies system resistance stimuli of users, focusing on the pre-adoption context in a forced ERP system environment. We have empirically validated the proposed research model by examining several significant factors affecting user resistance against the adoption of an ERP system. In particular, we find a clear and significant role of the moderating variable, prior ERP usage experience, in the relationship between the affecting factors and user resistance. The results of the study suggest the importance of appropriately managing the factors that affect user resistance in organizations that plan to introduce a new ERP system or integrate legacy systems. Moreover, this study offers to practitioners several specific strategies (in particular, the categorization of users by their prior usage experience) for alleviating the resistant behaviors of users in the process of the ERP adoption before a system becomes available to them. Despite the valuable contributions of this study, there are also some limitations which will be discussed in this paper to make the study more complete and consistent.

나선형그루브-금망의 복합윅을 갖는 히이트파이프의 전열특성에 관한 연구 (A Study on the Characteristics of Heat Transfer in Heat Pipe with Composition Wick of Screwed Groove - Metallic Mesh)

  • 장영석;이영수;서정일
    • 대한설비공학회지:설비저널
    • /
    • 제15권3호
    • /
    • pp.273-282
    • /
    • 1986
  • The purpose of this research was to study the characteristics of heat transfer in Heat Pipe which used the composition wick of screened groove - metallic mesh by ADI method and experimental results. As the results, the more than number of metallic mesh screen layers in a heat pipe increased, the fewer the effect of heat recovery decreased. In case of 1 - layer metallic mesh screen wick, the response of the effect in heat recovery was more rapidly showed than in case of other layers and in spite of high load, the evaporation section of Heat pipe with 1 - layer metallic mesh screen wick showed the stable response and did not show excessive super heat. There was a interrelation between thermal resistance and the variable layers, between thermal resistance and the variable gaps of metallic meshes, the heat transfer characteristics of Heat pipe were depended on the thermal resistance of composition wick.

  • PDF

태양 입사각에 따른 전력 변화 (Power Change According to the Angle of Solar Incidence)

  • 황미용;응우옌반흥;이순형;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권3호
    • /
    • pp.261-265
    • /
    • 2023
  • In this paper, we analyzed the transformation of the power following by the angle of incidence of the solar, the angle of photovoltaic module and artificial solar changed from 30° to 90° and synchronously changed the distance from 0.1 m to 0.5 m. Setting the distance between the artificial solar and the luminometer from 0.1 m to 0.5 m and set the angles to 90°, 60°, 45°, and 30°, the angle was 90° and when the distance was 0.1 m, the maximum Illuminance was 19,580 lux, the light could be obtained more. If the angle of incidence between the Artificial solar and the photovoltaic module was 90° and the variable resistance was 1,000 Ω at a distance of 0.4 m, the maximum power reached 0.82 W. Provided that the angle of incidence between the artificial solar and the photovoltaic module was 90° and the distance was 0.2 m since the variable resistance had the maximum power of 500 Ω, the maximum power was 0.78 W. At 1,000 Ω, the maximum power is 0.80 W so the maximum power at the variable resistance 1,000 Ω could obtain higher power than the variable resistance 500 Ω. The variable resistance was 1,000 Ω and the angle of incidence between the Artificial solar and the photovoltaic module was 90° at a distance of 0.4 m, and the maximum power reached 0.82 W. The angle was 60° at 0.3 m and 0.4 m the maximum power reached 0.10 W. The angle was 45° at 0.2 m maximum power reached 0.020 W, the angle was 30° at 0.4 m, and the maximum power reached 0.004 W. In four results about maximum power depending on the angle of incidence between the artificial solar and the photovoltaic module, the luminous efficiency and maximum power can be got the best at an angle of 90°.

Comparison of Kinematics and Myoelectrical Activity during Deadlift, with and without Variable Banded Resistance, in Healthy, Trained Athletes

  • Everett B. Lohman;Mansoor Alameri;Fulden Cakir;Chih Chieh Chia;Maxine Shih;Owee Mulay;Kezia Marceline;Simran Jaisinghani;Gurinder Bains;Michael DeLeon;Noha Daher
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권1호
    • /
    • pp.53-70
    • /
    • 2024
  • Background: The conventional deadlift is a popular exercise for enhancing trunk, core, and lower extremity strength. However, its use in sports medicine is constrained by concerns of lumbar injuries, despite evidence supporting its safety and rehabilitative benefits. To optimize muscle activation using resistive bands in variable resistance therapy, we explored their feasibility in the deadlift. Design: Comparative experimental design Methods: Surface electromyography recorded muscle activity in the trunk and lower extremities during lifting, with normalization to the isometric Floor Lift using Maximal Voluntary Contraction. Kinematics were measured using inclinometer sensors to track hip and trunk sagittal plane angles. To prevent fatigue, each subject only used one of the three pairs of bands employed in the study. Results: Our study involved 45 healthy subjects (mean age: 30.4 ± 6.3 years) with similar baseline characteristics, except for years of lifting and strength-to-years-of-lifting ratio. Various resistance band groups exhibited significantly higher muscle activity than conventional deadlifts during different phases. The minimal resistance band group had notably higher muscle activity in the trunk, core, and lower extremity muscles, particularly in the end phase. The moderate resistance band group showed increased muscle activity in the mid-and end-phases. The maximum resistance band group demonstrated greater muscle activity in specific muscles during the early phase and overall higher activity in all trunk and lower extremity muscles in the mid and end phases of the deadlift (p<0.05). Conclusion: Our findings provide valuable insights into muscle activation with various resistance bands during deadlift exercise in clinical and gym settings. There appears to be a dose-response relationship between increased resistance bandwidth, external load, myoelectric activation, and range.

극저온에서 금속표면의 열 접촉 저항 측정 (Thermal Contact Resistance Measurement of Metal Interface at Cryogenic Temperature)

  • 김명수;최연석
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.32-37
    • /
    • 2014
  • The thermal contact resistance (TCR) is one of the important resistance components in cryogenic systems. Cryogenic measurement devices using a cryocooler can be affected by TCR because the device has to consist of several metal components that are in contact with each other for heat transfer to the specimen without a cryogen. Therefore, accurate measurement and understanding of TCR is necessary for the design of cryogenic measurement devices using a cryocooler. The TCR occurs at the interface between metals and it can be affected by variable factors, such as the roughness of the metal surface, the contact area and the contact pressure. In this study, we designed a TCR measurement system at variable temperature using a cryocooler as a heat sink. Copper was selected as a specimen in the experiment because it is widely used as a heat transfer medium in cryogenic measurement devices. We measured the TCR between Cu and Cu for various temperatures and contact pressures. The effect of the interfacial materials on the TCR was also investigated.

유선추적법(流線追跡法)에 의(依)한 구상선수선형(球狀船首船型)의 계획(計劃) 및 조파효과(造波效果) (Desigh and Wavemaking Effect of Bulvous Bow Ship by Stream Line Tracing Method)

  • 홍성완
    • 대한조선학회지
    • /
    • 제10권2호
    • /
    • pp.19-28
    • /
    • 1973
  • This paper deals with a problem for determining the bulbous bow ship from which pertains to the study of the theoretical ship form planing method. In this paper has been determined the bulbous bow ship form which is a similar in geometric particulars with the conventional liner ship G.T.10, 000 by adopting the variable method for finding the optimum ship form by A.Y.C. Lee and the streamline tracing method by T. Inui and P.C. Pien. Each resistance performance is examined by the towing test and is compared with one another. The followings are the outcome of this study: Among the 5 type models, the bulbous bow ship form M.S. B 1120 is the most excellent for the resistance performance. The effect for the wave resistance is very sharp according to the difference of the bottom flattening of theoretical ship form. The optimum value of the bulbous bow for wave resistance can be obtained by the variable method mentioned above, and for the series of(Main hull+Bulb)opt., ${\alpha}=75/25$, the value is $f{\approx}0.11$.

  • PDF

화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구 (A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession)

  • 정병선;김응식;박종열
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

온도 의존성 가변 저항 발열체로 표면 처리된 금속 분리판 제조 및 평가 (Synthesis and Evaluation of Variable Temperature-Electrical Resistance Materials Coated on Metallic Bipolar Plates)

  • 정혜미;노정훈;임세준;이종현;안병기;엄석기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.73.1-73.1
    • /
    • 2010
  • For the successful cold starting of a fuel cell engine, either internal of external heat supply must be made to overcome the formation of ice from water below the freezing point of water. In the present study, switchable vanadium oxide compounds as variable temperature-electrical resistance materials onto the surface of flat metallic bipolar plates have been prepared by a dip-coating technique via an aqueous sol-gel method. Subsequently, the chemical composition and micro-structure of the polycrystalline solid thin films were analyzed by X-ray diffraction, X-ray fluorescence spectroscopy, and field emission scanning electron microscopy. In addition, it was carefully measured electrical resistance hysteresis loop over a temperature range from $-20^{\circ}C$ to $80^{\circ}C$ using the four-point probe method. The experimental results revealed that the thin films was mainly composed of Karelianite $V_2O_3$ which acts as negative temperature coefficient materials. Also, it was found that thermal dissipation rate of the vanadium oxide thin films partially satisfy about 50% saving of the substantial amount of energy required for ice melting at $-20^{\circ}C$. Moreover, electrical resistances of the vanadium-based materials converge on an extremely small value similar to that of pure flat metallic bipolar plates at higher temperature, i.e. $T{\geq}40^{\circ}C$. As a consequence, experimental studies proved that it is possible to apply the variable temperature-electrical resistance material based on vanadium oxides for the cold starting enhancement of a fuel cell vehicle and minimize parasitic power loss and eliminate any necessity for external equipment for heat supply in freezing conditions.

  • PDF