• Title/Summary/Keyword: Valve closure and opening

Search Result 11, Processing Time 0.023 seconds

Pressure Locking and Thermal Binding Analysis of the RHR Motor Operated Valve (잔열제거계통 모터구동밸브의 압력잠김 및 열고착 현상 분석)

  • Song, Eun-Sil;Kim, Tae-Il;Lee, Kwang-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.630-635
    • /
    • 2001
  • The stem thrust required to unwedging a gate valve is influenced by the pressure and temperature when the valve is closed and by the changes in these conditions between closure and opening. "Pressure Locking" and "Thennal Binding" refer to situations where pressure and temperature effects cause the unwedging load to be much higher than normal. A model of these phenomena has been developed. The effects of pressure and temperature are analyzed to determine the change in this disk-to-seat "interference". Flexibilities or Stiffness of the disk and body strongly influence the unwedging thrust. Calculation and limited comparison to data have been performed for the RHR motor operated valve designs and scenario. Pressure changes can increase the unwedging thrust when bonnet pressure exceeds the pressure in the adjacent piping and temperature changes can increase the unwedging thrust when a temperature change after closure produces an increase in the disk-to-seat interference.

  • PDF

Internal Flow Analysis for a 10 inch Ball Valve using Flow Similarity (유동상사를 이용한 10인치 볼밸브 내부유동 분석)

  • LEE, SANG-MOON;JANG, CHOON-MAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.4
    • /
    • pp.386-392
    • /
    • 2015
  • Flow characteristics inside a 10 inch ball valve have been analyzed using three-dimensional numerical analysis and experiments. Continuity and three-dimensional Reynolds-averaged Navier-Stokes equations have been used as governing equations for the numerical analysis. The numerical model has been constructed through the grid dependency test and validation with the results of experiments to ensure reliability and numerical effectiveness. The shear stress transport (SST) model has been used as the turbulence closure. The experimental test-rig has been constructed to measure pressure, temperature and flow rate along the pipeline. Some valve opening angles have been tested to evaluate the flow characteristics inside the ball valve and pipeline. The results show that the rapid pressure variations is observed while the valve opening angle decreases, which caused by flow separation at the downstream of the ball valve.

The Effect of Air Chamber Placed in Water Supply Piping System (급수배관계에서 에어 챔버의 설치효과에 관한 연구)

  • 이용화;최국광
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1047-1055
    • /
    • 2002
  • The present study is to investigate the pressure wave characteristics and the absorption of the maximum and minimum pressure generated by instantaneous valve closure and opening at the end of the straightening copper Piping system with and without an air chamber. Also, life of air chamber is investigated. Experiments were conducted under the following conditions: initial pressure of 1~5 bar, flow velocity of 0.5~3.0 m/s, water temperature of$20^{\circ}C$ and air chamber volume of 45.1~449.5$cm^3$ The results of the study can be used in sizing air chamber and selecting the water hammer absorbtion apparatus.

Clinical Study for Surgical Treatment of Congenital Heart Diseases (선천성 심혈관 질환의 수술요법에 관한 임상적 고찰)

  • 양태봉
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.390-396
    • /
    • 1991
  • From July 1984 to September 1990, 316 patients of congenital heart diseases were operated and 15 patients died. Hospital mortality was 4.75%. Five patients of 73 PDA had residual shunt after operation: 4 were ligated under support of Dacron patch, 1 was closed through the pulmonary arteriotomy under CPB. 3 patients were reoperated. No patient had residual shunt or reopening among the patients of simple ligation or division and suture. During the ligation of PDA, Dacron patch for protection from tearing may disturb the complete interruption of shunt. If the tissue around the ductus arteriosus looks weak or fragile, division and suture may be more reliable other than ligation with supporting patch. If the septal leaflet of tricuspid valve is adherent around the VSD, remained opening of VSD may be closed with simple suture directly. In these cases, the incidence of postoperative residual shunt is as high as the incidence of more large VSD closed with patch [10.9%: 9.6%]. During the direct closure of remained opening of VSD, another leaking route should be looked for carefully beneath the septal leaflet of tricuspid valve.

  • PDF

Clinical Study of Prosthetic Heart Valve Replacement with CarboMedics. (CarboMEdics 기계판막을 이용한 심장판막 치환술의 임상 연구)

  • 장원기;구자홍;조중구;김공수
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Background: The CarboMedics prosthetic heart valve was produced in an attempt to improve the existing valve designs and was especially concerned with easily the implantation and further reduction of turbulence. Precise positioning of the valve in situ was achieved by the abilityof the valve to rotate relative to the sewing ring. Improved monitoring is possible due to increased radiopacity and the dacron sewing ring is coated with carbon to reduce pannus overgrowth. The leaflets have an opening angle of 78 degrees that apparently allows a rapid synchronous closure The aim of this study was to analyze the clinical performance of the CarboMedics valve prostheses(45 mitral 13 aortic and 7 double aortic-mitral valve replacement) were implanted in 65 patients(mean age 48.75$\pm$9.74 years) Result: The operative mortality was 3.1%(2/65) causes of death were low cardiac output syndrome. Total follow up was 1831 patient-months and mean follow up was 29.06$\pm$10.97 months/patient. No structural failure hemorrhage valve thrombosis and late death have been observed. Embolism occurred at a rate of 0.65%/Patient-year. Actuarial survival and thrombo-mbolism free rate at 36 months were 96.9% and 98.4% respectively. Consclusions: The CarboMedics valve stands for low valve related complicatons.

  • PDF

Analysis of Flow through High Pressure Bypass Valve in Power Plant (발전소용 고압 바이패스 밸브의 유동해석)

  • Cho, An-Tae;Kim, Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2558-2562
    • /
    • 2007
  • In the present work, flow characteristics analysis has been performed for steam turbine bypass control valve (single-path type). The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. Shear stress transport (SST) model is used as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. Mass flow rate at maximum plug opening condition is compared with the designed mass flow rate.

  • PDF

Examination of Cavitation-Induced Surface Erosion Pitting of a Mechanical Heart Valve Using a Solenoid-Actuated Apparatus

  • Lee, Hwan-Sung;Hwang, Sung-Won;Katsuyuki Yamamoto
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.9
    • /
    • pp.1339-1348
    • /
    • 2003
  • Several factors, including peak dp/dt of the ventricular pressure and maximum closing velocity of leaflet have been studied as indices of the cavitation threshold. In the present study, just before closing velocity of the leaflet has been studied as indices of the cavitation threshold, and cavitation erosion on the surface of a mechanical valve was examined by focusing on squeeze flow and the water hammer phenomenon during the closing period of the valve. A simple solenoid-actuated test device that can directly control the valve closing velocity was developed, and opening-closing tests of 3,000 and 40,000 cycles were performed at various closing velocities. There was a closing velocity threshold to occur erosion pitting of valve surface, and its value was about 0.4 m/s in this study. Cavitation-induced erosion pits were observed only in regions where squeeze flow occurred immediately before valve closure On the other hand, the number of the pits was found to be closely related to an area of water hammer-induced pressure wave below the critical pressure defined by water vapor pressure. Therefore, it was concluded that cavitation is initiated and augmented by the two pressure drops due to squeeze flow and water hammer phenomenon, respectively.

Analysis of Flow through High Pressure Bypass Valve in Power Plant (발전소용 고압 바이패스 밸브 내부 유동해석)

  • Cho, An-Tae;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.17-23
    • /
    • 2007
  • In the present work, flow analysis has been performed in the steam turbine bypass control valve (single-path type) for two different cases i.e., case with steam only and case with both steam and water. The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. The shear stress transport (SST) model and $k-{\varepsilon}$ model are used to each different case as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. The mass flow rate at maximum plug opening condition is compared with the designed mass flow rate. The numerical analysis of multiphase mixing flow(liquid and vapor) is also performed to inspect liquid-vapor volume fraction of bypass valve. The result of volume fraction is useful to estimate both the safety and confidence of valve design.

Subannular Aortic Aneurysm Accompanied with Subacute Bacterial Endocarditis.- Report of one case - (아급성 심내막염을 동반한 대동맥륜 하부 대동맥류의 수술치험 -1례 보고-)

  • Han, Jae-Jin;Yi, Won-Yong;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.1084-1087
    • /
    • 1989
  • Subannular aortic aneurysm is a word-wide rare disease entity occurring predominantly in young black men. In Korea, there has been no report. We report one patient, 46 years old man, who had been operated urgently because of acute aortic insufficiency and aortic valvular vegetation after antibiotics treatment of Subacute bacterial endocarditis for 6wks. At the operative field, We found the bulging aneurysmal mass between the aorta and superior vena cava above the right pulmonary artery, which has subannular communicating opening into the left ventricular cavity, beneath the anterior commissure of the bicuspid aortic valve. Pathologic findings are consistent with "portion of vascular wall with features of aneurysm.* The patients survived aortic valve replacement and patch closure of subannular aneurysm, with no symptoms at one-year postoperative follow-up.w-up.

  • PDF