Examination of Cavitation-Induced Surface Erosion Pitting of a Mechanical Heart Valve Using a Solenoid-Actuated Apparatus

  • Lee, Hwan-Sung (Department of Biomedical Engineering, Korea University) ;
  • Hwang, Sung-Won (Graduate School of Engineering, Chonbuk National University) ;
  • Katsuyuki Yamamoto (Division of Biomedical System Engineering, Graduate School of Engineering, Hokkaido University)
  • Published : 2003.09.01

Abstract

Several factors, including peak dp/dt of the ventricular pressure and maximum closing velocity of leaflet have been studied as indices of the cavitation threshold. In the present study, just before closing velocity of the leaflet has been studied as indices of the cavitation threshold, and cavitation erosion on the surface of a mechanical valve was examined by focusing on squeeze flow and the water hammer phenomenon during the closing period of the valve. A simple solenoid-actuated test device that can directly control the valve closing velocity was developed, and opening-closing tests of 3,000 and 40,000 cycles were performed at various closing velocities. There was a closing velocity threshold to occur erosion pitting of valve surface, and its value was about 0.4 m/s in this study. Cavitation-induced erosion pits were observed only in regions where squeeze flow occurred immediately before valve closure On the other hand, the number of the pits was found to be closely related to an area of water hammer-induced pressure wave below the critical pressure defined by water vapor pressure. Therefore, it was concluded that cavitation is initiated and augmented by the two pressure drops due to squeeze flow and water hammer phenomenon, respectively.

Keywords

References

  1. Graf, T., Reul, H., Detlefs, C., Wilmes, R. and Rau, G., 1994, 'Causes and Formation of Cavitation in Mechanical Heart Valve,' J Heart Valve Disease, Vol, 3(Suppl. I), pp.49-64
  2. Klepetko, W., Moritz, A., Mlczoch, J., Schurawitzki, H., Domanig, E. and Wolner, E., 1989, 'Leaflet Facture in Edwards-Duromedics Bileaflet Valves,' J Thorae Cardiovsae Surg, Vol, 97, pp.90-94
  3. Lee, C. S., Chandran, K. B. and Chen, L. D., 1994, 'Cavitation Dynamics of Mechanical Heart Valve Prostheses,' Artif Organs, Vol, 18, pp.758-767 https://doi.org/10.1111/j.1525-1594.1994.tb03315.x
  4. Lee, C. S., Chandran, K. B. and Chen, L. D., 1996, 'Cavitation Dynamics of Medtronic Hall Mechanical Heart Valve Prosthesis: Fluid Squeezing Effect,' J Biomech Engineering, Vol, 118, pp.97-105 https://doi.org/10.1115/1.2795951
  5. Lee, H. S., Shimooka, T., Mitamura, Y., Yamamoto, K. and Yuhta, T., 2000, 'Surface Pitting of Heart Valve Disks Tested in an Accelerated Fatigue Tester,' Frontiers of Med and Biol Engineering, Vol, 10, pp. 167-176 https://doi.org/10.1163/15685570052062567
  6. Makhijani, V. B., Yang, H. Q., Singhal, A. K. and Hwang, N. H. C., 1994, 'An Experimental-Computational Analysis of MHV Cavitation: Effect of Leaflet Squeezing and Rebound,' J Heart Valve Disease, Vol, 3 ( Suppl. I), pp. 35-48
  7. Richard, G., Beavan, A. and Strzepa, P., 1994, 'Cavitation Threshold Ranking and Erosion Characteristics of Bileaflet Heart Valve Prostheses,' J Heart Valve Disease, Vol, 3 (Suppl. I), pp.94-101
  8. Shu, M. C. S., Leuer, L. H., Armitage, T. L., Schneider, T. E. and Christiansen, D. R., 1994, 'In Vitro Observations of Mechanical Heart Valve Cavitation,' J Heart Valve Disease, Vol, 3 (Suppl. I), pp. 85-93
  9. Wu, Z. J., Shu, M. C. S., Scott, D. R. and Hwang, N. H. C., 1994, 'The Closing Behavior of Medtronic Hall Mechanical Heart Valves ASAIO Journal, pp.702-706 https://doi.org/10.1097/00002480-199407000-00089