• 제목/요약/키워드: Valve Remote Control System

검색결과 31건 처리시간 0.029초

형상기억합금을 이용한 난방용 온도조절 밸브 및 원격 제어장치 개발 (Development of Heat Control Valve Using SMA and Remote Controller for House Heating System)

  • 최정주;염정국
    • 한국기계가공학회지
    • /
    • 제9권2호
    • /
    • pp.6-11
    • /
    • 2010
  • For the purpose of reducing the energy consumption in the house heating, the various devices have been developed. One of these is to control the flow in the heat pipe and the flow control valve using shape memory alloy(SMA) spring is proposed in our study. The proposed house heating system is to save the gas consumption and the remote control system is designed for the convenience of using the proposed valve. The developed valve consists of SMA spring, disk, return spring, and regulation handle. The regulation handle is for supplying the additional hot water and is controlled by remote-control-motor. In order to design the remote control system, the Zigbee wireless communication protocol is used. The performance of the proposed valve structure is shown through the experimental result.

체크밸브의 원격 상태감시 시스템 구현 (Realization of Remote Condition Monitoring System for Check Valve)

  • 이승연;전정섭;유준
    • 제어로봇시스템학회논문지
    • /
    • 제11권8호
    • /
    • pp.662-668
    • /
    • 2005
  • This paper presents a realization of check valve condition monitoring system based on fault diagnosis algorithm and Fieldbus communication. We first acquired AE(acoustic emission) sensor data at the check valve test loop, extract fault features through the teamed neural network, and send the processed data to a remote site. The overall system has been implemented and experimented results are given to show its effectiveness.

VRCS(Valve Remote Control System)의 적용설계에 관한 연구 (A Study on the Application Design for VRCS(Valve Remote Control System))

  • 박창권;김태형;정원지
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.272-278
    • /
    • 2002
  • At present most mechanical design engineers use the techniques that perform shape modeling, force analysis and DMU(Digital Mok-Up). This kind of design methods shorten the time of manufacturing prototypes and have a merit that decreases development cost. But a hydrauric system has inconvenience that engineers have to modify, and complement whenever needed, because simulation-based approaches are not ubiquitous compared to the case of general mechanical parts. This paper presents a case study of efficient application to hydrauric system for designing VRCS(Valve Remote Control System) using a Hycdraulic system design and analysis software.

  • PDF

A Study on the Prevention of Spill of Fuel Oils and Lubricating Oils for Sunken Ships

  • Han, Won-Heui;Ju, Hae-Ji
    • 해양환경안전학회지
    • /
    • 제21권3호
    • /
    • pp.309-314
    • /
    • 2015
  • A sunken ship often involves an oil spill. This paper was carried out to minimize environmental and cost damages stemming from oil spil of sunken shipl. Through the analysis of both the standards of the oil tank system and installation, we have identified potential oil spill sites and proposed a remedy of prevention. The result of study, the air pipes of the oil tank are a vulnerable point for oil spill. Also, the remote control devices of emergency shut-off valve have poor accessibility at abandon ship, making it difficult to shut off the emergency shut-off valve. Thus, we propose the addition of a remote quick closing valve in the air pipe and the building of a central control system.

유압원격제어를 위한 덤프와 감압밸브의 특성에 관한 연구 (A Study on Characteristics of Dump and Reducing Valve for Hydraulic Remote Control System)

  • 오철환;김광;송창섭
    • 한국정밀공학회지
    • /
    • 제5권3호
    • /
    • pp.81-90
    • /
    • 1988
  • In recent, the requirement of remote control of hychaulic system is in- creasing. The actuator unit whose output position is proportional to input electrical signal needs a pressure reducer and a dump valve. The pressure reducer provides a constant regulated pressure and filters contaminants. The dump valve supplies proper pressure to the pressure reducer and unloads when the system is not operated. In this thesis, dump valve and pressure reducer with auxiliary function are studied. The choke in the pressure reducer prevents actuator from supplying higher pressure than necessary pressure at beginning, and the spring constant affects on the dynamic characterisics. In dump valve, it is proved that diameter of servo-slide hold and choke diameter of dump plunger affects on damping response.

  • PDF

비례유량제어밸브 네트워크 제어기 설계 (Design of Network Controller for Proportional Flow Control Solenoid Valve)

  • 정규홍
    • 유공압시스템학회논문집
    • /
    • 제8권4호
    • /
    • pp.17-23
    • /
    • 2011
  • Proportional control solenoid is a type of modulating valve that can continuously control the valve position with magnetic force of solenoid. Recent microcontroller based digital servocontroller for proportional valve is being developed toward the smart valve with additional features such as enhanced control algorithm for finer process and intelligent on-board diagnosis for maintenance. In this paper, development of servocontroller network control with CAN bus which is free from problems of security and network traffic jam is presented. Design of network control system includes modes of communication between master and slave, assignment of 29bit message identifier and message objects, transaction of communication sequence, etc. Monitoring function and control experiments for remote valve through CAN network prove the extended function of smart valve control system.

전력선 통신 및 제어기능을 구비한 원격 밸브 제어시스템 개발 (Development of Remote Valve Control System with Power Line Communication)

  • 문형순;김종철;이병열;김용백;김지온
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2009년도 특별논문집
    • /
    • pp.71-79
    • /
    • 2009
  • The world-wide ship construction market is forecast that the considerable portion of shipbuilding and oceanic plant industry will be transferred consequently in China after 5 or 10 years. This point of view where the Korean ship construction industry seizes the initiative from the world-wide ship construction/oceanic field, we must cultivate technical power of base technology, and focus our interests on the development of core parts. In this study, our proprietary remotely operated valve actuator system with power line technology was developed to enhance the installation and commissioning process by our own technology. This paper describes the new design and functions of the remotely operated valve system for shipbuilding and offshore market especially for FPSO.

  • PDF

전자 유압식 비례 교축 제어 밸브의 특성 (Static and Dynamic Characteristics of Electro - hydraulic Proportional Throttle Control Valve)

  • 오인호;이일영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.87-99
    • /
    • 1993
  • Nowadays, the cartridge valve can be controlled proportionally in remote place by adopting proportional solenoid and it becomes widely used as control component in hydraulic systems. Especially, multi stage proportional valve is attractive because it consumes less input power though its characteristics might slightly be defected. But, the system parameter should be carefully chosen to obtain optimistic characteristics. This study concerning three stage proportional throttle control valve is purposed to examine the influences of paameters to the dynamic characteristics. The typical transient and frequency responses of proportional throttle control valve were inspected through the experiments and compared to those derived from the theoritical analyses. And it was confirmed that the analyses are appropriate. Then the influences of various system parameters to the dynamic characteristics were examined by means of simulations. For the analyses, the basic equations derived from lumped model were linearized and the linearized equations were transformed to the transfer functions between inputs and outputs. Then the transient responses and frequency responses were obtained from transfer functions. 1. It is appropriate to estimate the dynamic characteristics of valve which has relatively sophisticated structure by means of system analyses using linearized equations. 2. Though the valve has two pilot stages, fairly good characteristics can be obtained by carefully choosing system parameters. 3. Main valve very quickly follows the movement of second pilot valve when the parameters of main valve(the oil supply passage and discharge passage fpr second pilot valve) are appropriately chosen.

  • PDF

이중화 모드버스 통신을 이용한 퍼지기반 고장진단기능을 가진 선박 밸러스트 전기유압식 원격밸브제어시스템 개발 (Development of electro hydraulic ballast remote valve control system with diagnostic function using redundant modbus communication)

  • 김종현;유영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.292-301
    • /
    • 2014
  • 본 논문은 밸러스트 탱크용 분산형 독립전기유압식 원격밸브제어시스템을 개발하기 위하여 밸브개폐를 제어하는 슬레이브시스템과 다수의 슬레이브시스템을 제어감시하는 마스터시스템, 정보교환을 위하여 실시간 제어시스템에서 사용되는 이중화 모드버스 통신시스템, 선박의 통합관리 시스템에 접속 가능한 이더넷 모드버스 TCP/IP 통신시스템을 구현한다. 또한 퍼지기반 고장진단 시스템을 추가하여 시스템의 열화를 예측하고 정비시간을 단축함으로써 선박용 밸러스트 밸브 제어시스템의 안전성과 신뢰성을 높인다. 그리고 선박의 통합제어 시스템과 연계할 수 있는지를 확인할 수 있도록 이더넷 시뮬레이터를 개발하고 이들 장치의 시험에 대하여 기술한다.