• Title/Summary/Keyword: Value Measurement

Search Result 4,756, Processing Time 0.038 seconds

A PTV Applied to Measuring the Solid Particle Velocity of Slurry Flow in a Vertical Pipe (PTV를 이용한 수직관 내 슬러리유동의 고체입자 속도계측 연구)

  • Yang, Chan-Kyu;Choi, Jong-Su;Hong, Sup
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.213-219
    • /
    • 2001
  • In this paper, particle velocity of slurry flow, a kind of solid-particle two phase flow, was measured by using a particle tracking velocimetry. Particles are modeled by sphere-shaped glass whose diameters are 3mm, 5mm, and 7mm At first, a particle which is falling in the water is captured and analyzed to give their free falling velocity. The falling velocity was very high up to about 4m/sec in the air, which needs special algorithm for the accurate measurement. For the upwelling slurry flow in the straight duct, there are some noises caused by cavity. However, the effect was so small that it does not affect the measurement of large particles. From the preliminary study of applying the PTV to measurement of particle movement in slurry flow, we could find out the optimum value of parameters: threshold value., searching area radius and correlation area size.

  • PDF

Development of Back Analysis Program for Total Management Using Observational Method of Earth Retaining Structures under Ground Excavation (지반굴착 흙막이공의 정보화시공 종합관리를 위한 역해석 프로그램 개발)

  • 오정환;조철현;김성재;백영식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10c
    • /
    • pp.103-122
    • /
    • 2001
  • For prediction of ground movement per the excavation step, observational results of ground movement during the construction was very different with prediction during the analysis of design. step because of the uncertainty of the numerical analysis modelling, the soil parameter, and the condition of a construction field, etc. however accuratly numerical analysis method was applied. Therefore, the management system through the construction field measurement should be achieved for grasping the situation during the excavation. Until present, the measurement system restricted by ‘Absolute Value Management system’only analyzing the stability of present step was executed. So, it was difficult situation to expect the prediction of ground movement for the next excavation step. In this situation, it was developed that ‘The Management system TOMAS-EXCAV’ consisted of ‘Absolute value management system’ analyzing the stability of present step and ‘Prediction management system’ expecting the ground movement of next excavation step and analyzing the stability of next excavation step by‘Back Analysis’. TOMAS-EXCAV could be applied to all uncertainty of earth retaining structures analysis by connecting ‘Forward analysis program’ and ‘Back analysis program’ and optimizing the main design variables using SQP-MMFD optimization method through measurement results. The application of TOMAS-EXCAV was confirmed that verifed the three earth retaing construction field by back analysis.

  • PDF

A Study on Sexual Differentiation by Means of Discriminant Functions in the Dental Easurement (치열계측의 판별함수에 의한 성별판정에 관한 연구)

  • 배재일;김한평
    • Journal of Oral Medicine and Pain
    • /
    • v.8 no.1
    • /
    • pp.121-126
    • /
    • 1983
  • This study is conducted with a view to make correct sexual differentiation by the utilization of discriminant functions. For that purpose were randomly sampled out 148 young adults testes, comprising 67 males and 81 females, ranging from 15 through 18 years fo age. Based on the values made available from the measurement of 6 items corresponding to the maxillary cast models, a statistical analysis was made to abstract feasible discriminant functions. The results findings are as follows: 1. The mean value by sex indicates, in all items, higher one in male group than in female group. 2. Through the measurement were defined as singnificant items in sexual differentiation the bucco-lingual dimensions of canine, 1st-molar, 2nd molar, and 1st bimolat width. 3. Derived from the value from measurement items were discriminant functions with the intention of applying them to sexual differentiation, as follows: 1) Y=-25.4112+0.7513BL3+0.3298BL4-0.2854BL5+0.7350BL6-0.3482BL7+0.2893AW (as tested by Method I) 2)Y=-25.0628+0.7737BL3+0.7468BL6-0.3885BL5+0.2951AW(as tested by Method II) BL3 : Bucco-lingual dimension of upper canine BL4 : Bucco-lingual dimension of upper first prmolar BL5 : Bucco-lingual dimension of upper second premolar BL5 : Bucco-lingual dimension of upper first molar BL6 : Bucco-lingual dimension of upper second molar AW : Upper first bimolar width 4. Sexual defferentiation in terms of descriminant functions represented a probility of 74.6%.

  • PDF

Reliability Assessment of Temperature Indicator for Simplified Measurement on Conservation Environment of Cultural Heritage (문화재 보존환경 간이 측정을 위한 온도지시카드 신뢰성 평가)

  • Lim, Bo-A;Shin, Eun-Jeong;Lee, Sun-Myung
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.59-68
    • /
    • 2010
  • Cultural heritages are damaged by surrounding several environmental factors. Main factors are temperature, humidity, light, atmosphere and indoor pollutant, organism, etc. Therefore, to prevent damage of cultural heritage from such environmental factor, conservation environment monitoring becomes more important. Indicator is one of the simple method for environment monitoring. It can be used without expensive and complex equipments. However, it should be performed scientific examination for application to cultural heritage. In this study, some Temperature Indicators were chosen and reliability assessment was carried out for application to cultural heritage. Brightness($L^*$) is selected for reliability assessment factor. As a result of lab test, Temperature Indicators were not influenced greatly in humidity change. When they were exposed to setting temperature, the color was changed in setting temperature area and ${\pm}2^{\circ}C$ part of setting temperature. Especially brightness value was high in setting temperature area. Also, Temperature Indicators were stabilized after about 16 minutes when were exposed to temperature difference of $10^{\circ}C$ and when temperature difference with exposure environment is smaller, stabilization time shortened. Therefore, it is a possible to confirm that selected Temperature Indicator is reliable product through measurement of color difference value and naked eye observation.

  • PDF

Measurement Feasibility Assessment of Coating Film Thickness using Dual Sensor (이중센서를 이용한 코팅막 두께 측정 가능성 평가)

  • 김주현;김성렬;김정욱;김화영;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.78-81
    • /
    • 2004
  • A technical performance of the coating depends greatly on the thickness of painting film or coating film. Therefore the confirmed report of the technique to measure accurately is essential to the coating film thickness for the assessment about a coating quality performance. In this paper, two gap sensors - eddy current gap sensor and capacitance gap sensor - which has a different operating principle were used to measure the thickness of a nonmagnetic substance coating film such as paint, enamel or ceramic that was coated on the metallic material. A capacitance gap sensor was used to measure the distance between the sensor head and a coating film and an eddy current gap sensor to measure the distance between the sensor head and a base metal. Then the thickness of a coating film was obtained by the difference of two measurement value. At this result, the suggested dual sensor can measure an arbitrary film thickness to be coated on a base metal as the measurement value of coating thickness exists accurately within the 2% error.

  • PDF

Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging (웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발)

  • Ahn, Misook;Han, Yong-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

Estimation of Genetic Parameters and Breeding Value for Measurement Traits of Pacific Oyster Crassostrea gigas at Nine Months Old (9개월령 참굴의 계측형질에 대한 유전모수 및 육종가 추정)

  • Park, Ki-Yeol;Kim, Hyun-Chul;Kim, Byoung-Hak;Choi, Nack-Joong;Moon, Tae-Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.6
    • /
    • pp.600-603
    • /
    • 2009
  • Genetic and phenotypic parameter estimates for measurement traits were obtained from pacific oyster Crassostrea gigas at nine months old. For the growth-related traits among nine months old pacific oyster, heritabilities of shell length, shell height, shell width, total weight, body weight and shell weight were estimated as 0.4855, 0.5248, 0.0884, 0.7236, 0.7726 and 0.6957, respectively. Genetic correlations among the growth-related traits of pacific oyster at nines month old, shell length, shell height, shell width, total weight, body weight, shell weight were showing highly positive correlations. Breeding value on growth-related traits of pacific oyster at nine months old were estimated as shell length -7.044-11.870, shell height -11.380-18.370, shell width -1.234-2.831, total weight -8.339-17.140, body weight -1.813-3.507 and shell weight -4.422-8.837. The results show that there is quite substantial additive genetic variance for measurement traits in pacific oyster that can be exploited through selective breeding.

Uncertainty Analysis on Wind Speed Profile Measurements of LIDAR by Applying SODAR Measurements as a Virtual True Value (가상적 참값으로써 소다 측정자료를 적용한 라이다에 의한 풍속연직분포 측정의 불확도 분석)

  • Kim, Hyun-Goo;Choi, Ji-Hwi
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.79-85
    • /
    • 2010
  • The uncertainty in WindCube LIDAR measurements, which are specific to wind profiling at less than 200m above ground levelin wind resource assessments, was analyzed focusing on the error caused by its volume sampling principle. A two-month SODAR measurement campaign conducted in an urban environment was adopted as the reference wind profile assuming that various atmospheric boundary layer shapes had been captured. The measurement error of LIDAR at a height z was defined as the difference in the wind speeds between the SODAR reference data, which was assumed to be a virtually true value, and the numerically averaged wind speed for a sampling volume height interval of $z{\pm}12.5m$. The pattern of uncertainty in the measurement was found to have a maximum in the lower part of the atmospheric boundary layer and decreased with increasing height. It was also found that the relative standard deviations of the wind speed error ratios were 6.98, 2.70 and 1.12% at the heights of 50, 100 and 150m above ground level, respectively.

Automatic Color Recognition System for Stockigt Sizing Test (I) - Bias of Stockigt sizing test based on observer's subjectiveness - (스테키히트 시험용 자동 발색 인지 시스템 개발을 위한 기초연구(I) - Stockigt 사이즈도 시험법에 영향을 주는 요인 분석 -)

  • 김재옥;김철환;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • One of the most frequently used method for measurement of the degree of sizing (viz., hydrophobicity) is the Stockigt test. However, the Stockigt test was influenced by various factors such as dropping height, dropping amount, dropping speed and viewing angle. The resultant data of the sizing degree on the same specimen also varied according to different testers. Thus, the Stockigt test should be modified to be regarded as a highly reliable and reproducible standard method. For modifying the Stockigt test, it was required to quantify red coloration by reaction between 1% ferric chloride and 2% ammonium thiocyante during Stockigt testing. The cameras capturing the serial images during the red coloration process were the CMOS (Complementary Metal Oxide Semiconductor)-type and CCD (Charge Coupled Device)-type cameras. For measurement based on KS M 7025, the CCD-type camera must be used due to its high resolution, and on the other hand, for measurement based on Tappi Useful Method 429, the CMOS-type camera may be used owing to its low resolution. It was needed to covert the RGB values of a droplet image into HSV(Hue, Saturation, and Value) values because the human eyes are much closer to HSV than RGB. Among HSV values, the Hue value was accepted as the most reliable index consistent with the red coloration process by excluding the surrounding conditions such as light, tester's movement etc.

Measurement of a Mirror Surface Topography Using 2-frame Phase-shifting Digital Interferometry

  • Jeon, Seok-Hee;Gil, Sang-Keun
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.245-250
    • /
    • 2009
  • We propose a digital holographic interference analysis method based on a 2-frame phase-shifting technique for measuring an optical mirror surface. The technique using 2-frame phase-shifting digital interferometry is more efficient than multi-frame phase-shifting techniques because the 2-frame method has the advantage of a reduced number of interferograms, and then takes less time to acquire the wanted topography information from interferograms. In this measurement system, 2-frame phase-shifting digital interferograms are acquired by moving the reference flat mirror surface, which is attached to a piezoelectric transducer, with phase step of 0 or $\pi$/2 in the reference beam path. The measurements are recorded on a CCD detector. The optical interferometry is designed on the basis of polarization characteristics of a polarizing beam splitter. Therefore the noise from outside turbulence can be decreased. The proposed 2-frame algorithm uses the relative phase difference of the neighbor pixels. The experiment has been carried out on an optical mirror which flatness is less than $\lambda$/4. The measurement of the optical mirror surface topography using 2-frame phase-shifting interferometry shows that the peak-to-peak value is calculated to be about $0.1779{\mu}m$, the root-mean-square value is about $0.034{\mu}m$. Thus, the proposed method is expected to be used in nondestructive testing of optical components.