• Title/Summary/Keyword: Validation Rate

Search Result 711, Processing Time 0.033 seconds

Validation of a Rate-Sensitive Model for Clayey Soils (점성토에서 전단속도 의존 모델의 검증)

  • Kim, Dae-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.596-601
    • /
    • 2009
  • In this study, the rate-sensitive constitutive model, which was developed in the previous paper of this journal, was validated using the experimental results obtained from the well-calibrated triaxial compression test conducted with the Boston blue clay. The validation was performed for the various cases of the strain rate of 0.05%/hr, 0.5%/hr, 5.0%/hr and OCR of 1, 2, 4, 8. The developed model was validated for the normally and slightly overconsolidated cases; however, the cases of heavily overconsolidation needs further research.

A Feature Map Compression Method for Multi-resolution Feature Map with PCA-based Transformation (PCA 기반 변환을 통한 다해상도 피처 맵 압축 방법)

  • Park, Seungjin;Lee, Minhun;Choi, Hansol;Kim, Minsub;Oh, Seoung-Jun;Kim, Younhee;Do, Jihoon;Jeong, Se Yoon;Sim, Donggyu
    • Journal of Broadcast Engineering
    • /
    • v.27 no.1
    • /
    • pp.56-68
    • /
    • 2022
  • In this paper, we propose a compression method for multi-resolution feature maps for VCM. The proposed compression method removes the redundancy between the channels and resolution levels of the multi-resolution feature map through PCA-based transformation. According to each characteristic, the basis vectors and mean vector used for transformation, and the transformation coefficient obtained through the transformation are compressed using a VVC-based coder and DeepCABAC. In order to evaluate performance of the proposed method, the object detection performance was measured for the OpenImageV6 and COCO 2017 validation set, and the BD-rate of MPEG-VCM anchor and feature map compression anchor proposed in this paper was compared using bpp and mAP. As a result of the experiment, the proposed method shows a 25.71% BD-rate performance improvement compared to feature map compression anchor in OpenImageV6. Furthermore, for large objects of the COCO 2017 validation set, the BD-rate performance is improved by up to 43.72% compared to the MPEG-VCM anchor.

Validation of FDS for the Pool Fires within Two Rooms (이중격실 Pool 화재에 대한 FDS 검증분석)

  • Bae, Young-Bum;Ryu, Su-Hyun;Kim, Yun-Il;Lee, Sang-Kyu;Keum, O-Hyun;Park, Jong-Seok
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.60-67
    • /
    • 2010
  • Fire model shall be verified and validated to reliably predict the consequences of fires within its limitations. Generally the verification and validation procedures are conducted by comparison with experimental test data. This study aims to evaluate predictive capabilities of FDS in the pool fire with two rooms and the sensitivity between input parameters such as heat release rate and ventilation rate and the output values like temperature, concentration, and heat flux. The predictive capabilities of FDS will be evaluated by comparing FDS simulation results with PRISME experimental data which result from the international fire test project. The sensitivity analysis will be conducted to decide which one of input parameters affects outcomes by comparison of FDS results with ${\pm}$ 10% changes of input parameter. From this study, the FDS predictive capabilities are within 20% error range. Heat release rate as input parameter affects most of outcomes and flow rate only has relation with concentration of oxygen and combustion products.

Some Validation of Nonlinear ${\kappa}-{\varepsilon}$ Models on Predicting Noncircular Duct Flows

  • Myong H. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.43-45
    • /
    • 2003
  • Nonlinear relationship between Reynolds stresses and the rate of strain for nonlinear${\kappa}-{\varepsilon}$ turbulence models is validated theoretically by using the boundary layer assumptions against the turbulence­driven secondary flows in noncircular ducts and then the prediction performance for several nonlinear models is evaluated numerically through the application to the turbulent flow in a square duct.

  • PDF

Validation of MODIS fire product over Sumatra and Borneo using High Resolution SPOT Imagery

  • LIEW, Soo-Chin;SHEN, Chaomin;LOW, John;Lim, Agnes;KWOH, Leong-Keong
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1149-1151
    • /
    • 2003
  • We performed a validation study of the MODIS active fire detection algorithm using high resolution SPOT image as the reference data set. Fire with visible smoke plumes are detected in the SPOT scenes, while the hotspots in MODIS data are detected using NASA's new version 4 fire detection algorithm. The detection performance is characterized by the commission error rate (false alarms) and the omission error rate (undetected fires). In the Sumatra and Kalimantan study area, the commission rate and the omission rate are 27% and 34% respectively. False alarms are probably due to recently burnt areas with warm surfaces. False negative detection occur where there are long smoke plumes and where fires occur in densely vegetated areas.

  • PDF

Development of an Ejector System for Operating of Chemical Lasers (III) - Development and Performance Validation of a Full-Scale Ejector System for High Power Chemical Lasers - (화학레이저 구동용 이젝터 시스템 개발 (III) - 고출력 화학레이저용 실물 크기의 이젝터 시스템 개발 및 성능 검증 -)

  • Kim, Se-Hoon;Jin, Jung-kun;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.9-15
    • /
    • 2005
  • From the geometric parameter study, an optimal ejector design procedure of pressure recovery system for chemical lasers was acquired. For given primary flow reservoir conditions, an up-scaled ejector was designed and manufactured. In the performance test, secondary mass flow rate of 100g/s air was entrained satisfying the design secondary pressure, $40{\sim}50torr$. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of the diffuser at the secondary inlet further reduced diffuser upstream pressure to 7torr. Lastly, the duplicate of apparatus (air 500g/s secondary mass flow rate each) was built and connected in parallel to assess proportionality behavior on a system to handle larger mass flow rate. Test and comparison of the parallel unit demonstrated the secondary mass flow rate was proportional to the number of individual units that were brought together maintaining the lasing pressure.

Assessment of a Phase Doppler Anemometry Technique in Dense Droplet Laden Jet

  • Koo, Ja-Ye;Kim, Jong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.7
    • /
    • pp.1083-1094
    • /
    • 2003
  • This study represents an assessment of the phase-Doppler technique to the measurements of dense droplet laden jet. High-pressure injection fuel sprays have been investigated to evaluate the use of the Phase-Doppler anemometry (PDA) technique. The critical issue is the stability of the phase-Doppler anemometry technique for dense droplet laden jet such as Diesel fuel spray in order to insure the results from the drop size and velocity measurements are repeatable, consistent, and physically realistic because the validation rate of experimental data is very low due to the thick optical density. The effect of shift frequency is minor, however, the photomultiplier tube (PMT) voltage setting is very sensitive to the data acquisition and noise in dense droplet laden jet. The optimum PMT voltage and shift frequency should be chosen so that the data such as volume flux and drop diameter do not change rapidly.

Web-Based On-Line Thermal Performance Analysis System for Turbine Cycle of Nuclear Power Plant (온라인 웹기반 원전 터빈 사이클 열성능 분석 시스템)

  • Choi KiSang;Choi KwangHee;Ji MoonHak;Hong SeungYeol;Kim SeongKun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.409-416
    • /
    • 2005
  • We need to develop a on-line thermal performance analysis system for nuclear power plant to determine performance status and heat rate of turbine cycle. We have developed PERUPS(PERformance Upgrade System) to aid the effective performance analysis of turbine cycle. Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on PTC(Performance Test Code). Robustness in the on-line performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful web interfaces for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis report. The system was successfully applied for YongGwang nuclear plant unit #3,4.

Quantitation and Validation of Atorvastatin using HPLC-UV

  • Heine, Daniel;Yong, Chul-Soon;Kim, Jung-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.187-192
    • /
    • 2007
  • A reversed phase HPLC analysis of atorvastatin (AS) standard solution was performed using diclofenac (DF) as internal standard. Column oven temperature, flow rate and the composition of the mobile phase were varied in order to determine a practical system setup using a C18 column and UV detector. Two C18 columns of different length were compared regarding their influence on the AS peak shape. Based on these preliminary experiments a validation study was performed utilizing a C18 column at $62^{\circ}C$ with a mobile phase consisting of sodium phosphate buffer (0.05 M, pH 4.0), methanol and acetonitrile (40:50:10, v/v/v). The detection limit for AS was $0.1{\mu}g/ml$ and inter- and intra-day calibration curves were linear over a concentration range of $0.2-50{\mu}g/ml$. Accuracy and precision were satisfactory in the AS concentration range of $0.5-50{\mu}g/ml$.

Development of On-Line Diagnostic Expert System : Heuristics and Influence Diagrams (현장진단 전문가 시스템의 개발 : 휴리스틱과 인플루언스 다이아그램)

  • Kim, Young-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.1
    • /
    • pp.95-113
    • /
    • 1997
  • This paper outlines a framework for a diagnosis of a complex system with uncertain information. Sensor validation ploys a vital role in the ability of the overall system to correctly determine the state of a system monitored by imperfect sensors. Here, emphases are put on the heuristic technology and post-processor for reasoning. Heuristic Sensor Validation (HSV) exploits deeper knowledge about parameter interaction within the plant to cull sensor faults from the data stream. Finally the modified probability distributions and validated data are used as input to the reasoning scheme which is the runtime version of the influence diagram. The output of the influence diagram is a diagnostic mapping from the symptoms or sensor readings to a determination of likely failure modes. Once likely failure modes are identified, a detailed diagnostic knowledge base suggests corrective actions to improve performance. This framework for a diagnostic expert system with sensor validation and reasoning under uncertainty applies in $HEATXPRT^{TM}$ a data-driven on-line expert system for diagnosing heat rate degradation problems in fossil power plants [1].

  • PDF