DOI QR코드

DOI QR Code

Web-Based On-Line Thermal Performance Analysis System for Turbine Cycle of Nuclear Power Plant

온라인 웹기반 원전 터빈 사이클 열성능 분석 시스템

  • 최기상 (호서대학교 대학원 기계설계전공) ;
  • 최광희 (한국전력공사 전력연구원 원자력연구실) ;
  • 지문학 (한국전력공사 전력연구원 원자력연구실) ;
  • 홍승열 (한국전력공사 전력연구원 원자력연구실) ;
  • 김성근 (호서대학교 공과대학 기계설계전공)
  • Published : 2005.03.01

Abstract

We need to develop a on-line thermal performance analysis system for nuclear power plant to determine performance status and heat rate of turbine cycle. We have developed PERUPS(PERformance Upgrade System) to aid the effective performance analysis of turbine cycle. Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on PTC(Performance Test Code). Robustness in the on-line performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful web interfaces for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis report. The system was successfully applied for YongGwang nuclear plant unit #3,4.

Keywords

References

  1. Kim, S.K. and Choi, K.H., 2001, 'Development of Performance Analysis System (NOPAS) for Turbine Cycle of Nuclear Power Plant,' Journal of Korean Nuclear Society, Vol. 33 No. 1, pp. 211-218
  2. Kim, S.K. and Choi, K.H., 2000, 'Development of Performance Analysis Methodology for Nuclear Power Plant Turbine Cycle Using Validation Model of Performance Measurements,' Tran. of the KSME (B), Vol. 24, No. 12, pp. 1625-1634
  3. Kim, S.K. and Choi, K.H., 2000, 'Thermal Performance Analysis System Based on Measurement Validation for Nuclear Power Plant,' 4th KSME-JSME Thermal Engineering Conference
  4. Korea Hydraulic and Nuclear Co., 2003, 'User's Guide for PERUPS, Programmer's Guide for PERUPS, Technological Guide for PERUPS'
  5. Korea Hydraulic and Nuclear Co., 2003, 'Development of Thermal Performance Analysis Computer Program on Turbine Cycle of Yonggwang 3,4 Units,' Research Report Korea Hydraulic and Nuclear Co
  6. American Society of Mechanical Engineers, 1976, Performance Test Code 6, 'Steam Turbines,'
  7. American Society of Mechanical Engineers, 1982, Performance Test Code 6A, 'Appendix A to Test Code for Steam Turbines,'
  8. American Society of Mechanical Engineers, 1978, Performance Test Code 12.1, 'Closed Feed Water Heaters.'
  9. American Society of Mechanical Engineers, 1983, Performance Test Code 12.2, 'Steam Condensing Apparatus,'
  10. Glorian, D., 1995, 'Performance of Thermal Generating Plants Worldwide: Current Situation and Outlook,' 8th Int. Conference & Exhibition for the Power Generating Industries, USA, pp. 337-350
  11. Munchausen, J. H., 1995, 'EPRI Performance Enhancement Program,' Proceedings of the American Power Conference, USA, pp. 519-521
  12. Spencer, R.C., Cotton, K.C. and Cannon, C.N., 1974, 'A Method for Predicting the Performance of Steam Turbine-Generators, 16,500KW and Larger,' General Electric Co. Report
  13. British Electricity International, 1991, 'Modern Power Station Practice: Volume G Station Operation and Maintenance,'
  14. Kim, S.K. and Han, S.T., 1996, 'A Study on the Computerization of Performance Evaluation for Thermal Power Plant,' 3rd KSME-JSME Thermal Engineering Conference