• Title/Summary/Keyword: Vacuum-pressure treatment

Search Result 171, Processing Time 0.03 seconds

Role of Endoscopic Vacuum Therapy as a Treatment for Anastomosis Leak after Esophageal Cancer Surgery

  • Lee, Dong Kyu;Min, Yang Won
    • Journal of Chest Surgery
    • /
    • v.53 no.4
    • /
    • pp.205-210
    • /
    • 2020
  • Esophageal anastomotic leak is the most common and serious complication following esophagectomy. However, the standard treatment for anastomotic leaks remains unclear. Recently, endoscopic vacuum therapy has become an important non-surgical alternative treatment method for patients with esophageal anastomotic leak. This treatment involves the endoscopic placement of a sponge connected to a nasogastric tube into the defect cavity or lumen. Subsequently, continuous negative pressure is delivered to the cavity through the tube. Several studies have reported a treatment success rate of 80% to 100%. In this study, we review the mechanism of action, the method of performing the procedure, its safety and efficacy, and prognostic factors for failure of endoscopic vacuum therapy in the management of patients with anastomotic leak, and on this basis attempted to confirm the possibility of establishing a standardized treatment protocol using endoscopic vacuum therapy.

Shallow ground treatment by a combined air booster and straight-line vacuum preloading method: A case study

  • Feng, Shuangxi;Lei, Huayang;Ding, Xiaodong;Zheng, Gang;Jin, Yawei
    • Geomechanics and Engineering
    • /
    • v.24 no.2
    • /
    • pp.129-141
    • /
    • 2021
  • The vacuum preloading method has been used in many countries for soil improvement and land reclamation. However, the treatment time is long and the improvement effect is poor for the straight-line vacuum preloading method. To alleviate such problems, a novel combined air booster and straight-line vacuum preloading method for shallow ground treatment is proposed in this study. Two types of traditional vacuum preloading and combined air booster and straight-line vacuum preloading tests were conducted and monitored in the field. In both tests, the depth of prefabricated vertical drains (PVDs) is 4.5m, the distance between PVDs is 0.8m, and the vacuum preloading time is 60 days. The prominent difference between the two methods is when the preloading time is 45 days, the injection pressure of 250 kPa is adopted for combined air booster and straight-line vacuum preloading test to inject air into the ground. Based on the monitoring data, this paper systematically studied the mechanical parameters, hydraulic conductivity, pore water pressure, settlement and subsoil bearing capacity, as determined by the vane shear strength, to demonstrate that the air-pressurizing system can improve the consolidation. The consolidation time decreased by 15 days, the pore water pressure decreased to 60.49%, and the settlement and vane shear strengths increased by 45.31% and 6.29%, respectively, at the surface. These results demonstrate the validity of the combined air booster and straight-line vacuum preloading method. Compared with the traditional vacuum preloading, the combined air booster and straight-line vacuum preloading method has better reinforcement effect. In addition, an estimation method for evaluating the average degree of consolidation and an empirical formula for evaluating the subsoil bearing capacity are proposed to assist in engineering decision making.

Resin Impregnation of Sawdust Board for Making Woodceramics (I) - Effect of Impregnation Method and Time on Physical and Mechanical Properties -

  • Oh, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.25-32
    • /
    • 2004
  • This research work explored physical and mechanical properties of impregnated sawdust boards from three softwood species (P, densifora, L. kaemferi, and P. koraiensis) with phenol-formaldehyde (PF) resin by various vacuum treatment methods of combining pressure, vacuum, and ultrasonic waves. Simultaneous vacuum and ultrasonic wave treatments with no pressure resulted in the greatest increase in resin content, density, dimensional changes (thickness and length), bending strength, and hardness of impregnated board. This result seemed to be attributed to the ultrasonic wave treatment.

Field instrumentation and settlement prediction of ground treated with straight-line vacuum preloading

  • Lei, Huayang;Feng, Shuangxi;Wang, Lei;Jin, Yawei
    • Geomechanics and Engineering
    • /
    • v.19 no.5
    • /
    • pp.447-462
    • /
    • 2019
  • The vacuum preloading method has been used in many countries for ground improvement and land reclamation works. A sand cushion is required as a horizontal drainage channel for conventional vacuum preloading. In terms of the dredged-fill foundation soil, the treatment effect of the conventional vacuum preloading method is poor, particularly in Tianjin, China, where a shortage of sand exists. To solve this problem, straight-line vacuum preloading without sand is widely adopted in engineering practice to improve the foundation soil. Based on the engineering properties of dredged fill in Lingang City, Tianjin, this paper presents field instrumentation in five sections and analyzes the effect of a prefabricated vertical drain (PVD) layout and a vacuum pumping method on the soft soil ground treatment. Through the arrangement of pore water pressure gauges, settlement marks and vane shear tests, the settlement, pore water pressure and subsoil bearing capacity are analyzed to evaluate the effect of the ground treatment. This study demonstrates that straight-line vacuum preloading without sand can be suitable for areas with a high water content. Furthermore, the consolidation settlement and consolidation degree system is developed based on the grey model to predict the consolidation settlement and consolidation degree under vacuum preloading; the validity of the system is also verified.

Pressure Effect on Safranine Penetration in Some Hardwood Species

  • Chong, Song-Ho;Ahmed, Sheikh Ali;Park, Byung-Su;Chun, Su-Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.18 no.2
    • /
    • pp.111-119
    • /
    • 2007
  • An experiment was conducted to know the safranine impregnation distance from surface to inward using 6 different hardwood species. During impregnation, 3 parameters were applied-vacuum, pressure and soaking time. Only vacuum treatment did not increase the permeability of wood. Vacuum followed by pressure increased the penetration depth of safranine in radial, tangential and longitudinal direction. Longitudinal penetration was found easy to impregnate. Comparing with radial and tangential direction, radial penetration was found easy. There was a striking difference among sapwood and heartwood permeability. Safranine input depth was found highest in diffused porous wood rather than in ring porous wood. At increased vacuum and pressure, safranine penetration was found easy.

  • PDF

Evaluation of Effectiveness of Vacuum Oral Cleaner Developed for Patients with Limited Mobility

  • Lee, Jae-Hyun;Jung, Ki-Won;Kim, Hee-Kyung;Koo, Ki-Tae;Kim, Sung-Hun
    • The Journal of the Korean dental association
    • /
    • v.54 no.12
    • /
    • pp.1035-1044
    • /
    • 2016
  • Purpose : The purpose of this study was to compare the plaque removal effects of vacuum oral cleaner developed for the patients with limited mobility with those of manual toothbrushes and high pressure injection oral cleaner (dental water jet). Meterials and methods : Thirty human subjects were measured with Patient Hygiene Performance index (PHP index) and O'Leary index before and after the use of toothbrush, high pressure injection oral cleaner and vacuum oral cleaner. These three different oral hygiene methods were conducted with seven-day intermittence. Then the statistical analysis was carried out to define plaque removal rate of three different oral hygiene methods (${\alpha}=.05$). Results : According to the efficacy analysis of plaque removal before and after the oral cleaning using each of three methods, significant reduction in plaque after the treatment compared to the previous state when using toothbrush, high pressure injection oral cleaner, and vacuum oral cleaner was observed (P < 0.001). PHP index of tooth brushing was higher than that of the high pressure injection oral cleaner, while PHP index of vacuum oral cleaner did not show significant difference from either of the other two methods. There was no significance difference in O'Leary index among the three methods. Conclusion : Effect of plaque removal using the vacuum oral cleaner is comparable to that of manual tooth brush or high pressure injection oral cleaner, so it will be helpful for self-oral hygiene care of the patients with limited mobility.

  • PDF

Vacuum Pressure Treatment of Water-Soluble Melamine Resin Impregnation for Improvement of Mechanical Property, Abrasion Resistance and Incombustibility on Softwood (목재의 기계적 성질, 내마모성 및 난연성 개선을 위한 진공가압 멜라민 수지함침처리)

  • Oh, Seung-Won;Park, Hee Jun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.792-797
    • /
    • 2015
  • In this study, three softwood species were treated with water-soluble melamine resin by different concentration and treatment time under vacuum pressure for improving mechanical property, abrasion resistance, and incombustibility. After the treatment, a compreg was manufactured and then evaluated on physical properties. Additionally, incombustibility of compreg was determined by comparing with a wood that was treated by spraying a water-soluble fire retardant on surface. As concentration of resin increased, bending strength and Brinell hardness increased as well as abrasion resistance, but there was no correlation on treatment and mechanical properties by treatment time. The wood impregnated by water-soluble melamine resin under vacuum pressure showed better incombustibility than that of a water-soluble fire retardant sprayed wood. Therefore, this treatment could be used for improving incombustibility of wood.

A Study on Sewage Sludge Treatment by Vacuum Drying Method (감압건조법(減壓乾燥法)을 이용(利用)한 하수(下水)슬러지처리(處理))

  • Jang, Seong-Ho;Park, Jin-Sick;Kim, Soo-Saeng
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.1
    • /
    • pp.67-73
    • /
    • 1998
  • This study was to experiment, through sewage sludge treatment by Vacuum Drying Method, variation of water content with reaction pressure, reaction time, reaction temperature. The result are as follows; The water content decreased with the same reaction temperature and reaction time at lower pressure and 360~40 mmHg (a close vacuum) showed lower water content at low reaction temperature and short reaction time. The water content rapidly decreased with the same reaction pressure and time at low reaction temperature (above $120^{\circ}C$).

  • PDF

Development of an advanced atmospheric pressure plasma source with high spatial uniformity and selectiveness for surface treatment

  • Im, Yu-Bong;Choe, Won-Ho;Lee, Seung-Hun;Han, U-Yong;Lee, Jong-Hyeon;Lee, Sang-Gyun;Ha, Jeong-Min;Kim, Jong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.176-177
    • /
    • 2016
  • In the last few decades, attention toward atmospheric pressure plasma (APP) has been greatly increased due to the numerous advantages of those applications, such as non-necessity of high vacuum facility, easy setup and operation, and low temperature operation. The practical applications of APP can be found in a wide spectrum of fields from the functionalization of material surfaces to sterilization of medical devices. In the secondary battery industry, separator film has been typically treated by APP to enhance adhesion strength between adjacent films. In this process, the plasma is required to have high stability and uniformity for better performance of the battery. Dielectric barrier discharge (DBD) was usually adopted to limit overcurrent in the plasma, and we developed the pre-discharge technology to overcome the drawbacks of streamer discharge in the conventional DBD source which makes it possible to produce a super-stable plasma at atmospheric pressure. Simulations for the fluid flow and electric field were parametrically performed to find the optimized design for the linear jet plasma source. The developed plasma source (Plasmapp LJPS-200) exhibits spatial non-uniformity of less than 3%, and the adhesion strength between the separator and electrode films was observed to increase 17% by the plasma treatment.

  • PDF

IGZO 박막 표면의 수소 이온 빔 처리 효과

  • Lee, Seung-Su;Min, Gwan-Sik;Yun, Ju-Yeong;O, Eun-Sun;Jeong, Jin-Uk;Kim, Jin-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.154.1-154.1
    • /
    • 2014
  • Indium gallium zinc oxide (IGZO)는 차세대 디스플레이 평판 패널에 사용되는 반도체 화합물의 일종으로 최근 주목받고 있는 물질의 하나이다. 기존의 IGZO를 사용하여 박막을 증착한 뒤 표면 처리를 통해 박막의 특성 변화에 대한 연구들이 진행되어 왔으며, 기존의 연구들은 plasma 환경에 노출을 시켜 간접적인 plasma treatment를 통해 박막의 특성을 향상시켜 왔다. 본 연구에서는 기존의 plasma treatment에서 발견된 방식인 ion beam treatment를 통해 플라즈마를 직접적으로 표면에 조사하여 박막의 특성 변화를 알아보았다. 한국표준과학연구원에서 자체 제작한 chamber를 이용하여 RF sputter로 Si wafer 위에 IGZO 박막을 증착하고 수소 ion beam treatment를 한 뒤, SEM과 XPS를 사용하여 박막 표면의 물성 변화를 분석하였다. 실험에 사용된 chamber에는 sputter gun과 ion beam이 함께 장착되어 있으며, scroll pump와 TMP를 사용하여 pressure를 유지하였다. 실험 시 base pressure는 $1.4{\times}10^{-6}Torr$였다. RF power 150 W. ion beam power 2,000 V에서 실험을 진행하였다.

  • PDF