• 제목/요약/키워드: Vacuum therapy

검색결과 58건 처리시간 0.03초

Large-scale Synthesis of Uniform-sized Nanoparticles for Multifunctional Medical Applications

  • Hyeon, Taeg-Hwan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.1-1
    • /
    • 2011
  • We developed a new generalized synthetic procedure, called as "heat-up process," to produce uniform-sized nanocrystals of many transition metals and oxides without a size selection process. We were able to synthesize uniform magnetite nanocrystals as much as 1 kilogram-scale from the thermolysis of Fe-oleate complex. Clever combination of different nanoscale materials will lead to the development of multifunctional nano-biomedical platforms for simultaneous targeted delivery, fast diagnosis, and efficient therapy. In this presentation, I would like to present some of our group's recent results on the designed fabrication of multifunctional nanostructured materials based on uniform-sized magnetite nanoparticles and their medical applications. Uniform ultrasmall iron oxide nanoparticles of <3 nm were synthesized by thermal decomposition of iron-oleate complex in the presence of oleyl alcohol. These ultrasmall iron oxide nanoparticles exhibited good T1 contrast effect. In in vivo T1 weighted blood pool magnetic resonance imaging (MRI), iron oxide nanoparticles showed longer circulation time than commercial gadolinium complex, enabling high resolution imaging. We used 80 nm-sized ferrimagnetic iron oxide nanocrystals for T2 MRI contrast agent for tracking transplanted pancreatic islet cells and single-cell MR imaging. We reported on the fabrication of monodisperse magnetite nanoparticles immobilized with uniform pore-sized mesoporous silica spheres for simultaneous MRI, fluorescence imaging, and drug delivery. We synthesized hollow magnetite nanocapsules and used them for both the MRI contrast agent and magnetic guided drug delivery vehicle.

  • PDF

구강암 수술 후 발생한 구강 경부 누공(orocutaneous fistula) 치료 시 진공 음압 폐쇄(vacuum-assisted closure) 시스템을 이용한 상처 치료 (Postoperative orocutaneous fistula closure using a vacuum-assisted closure system: a case report)

  • 이승준;권진일;임경민;김형준;차인호;남웅
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권5호
    • /
    • pp.413-416
    • /
    • 2010
  • Fleischmann et al. first described the concept of using sub-atmospheric pressure to treat open or infected wounds in 1993. Since then, Argenta and Morykwas developed subatmospheric, or negative pressure dressings in 1997 as a means of managing complicated wounds. Since its introduction in 1997, the vacuum-assisted closure (VAC) system has been used widely in general plastic surgery, general surgery, and orthopedic surgery to manage complicated wounds of the torso and extremities. However, there is a paucity of literature describing its use in the head and neck region, particularly in oral and maxillofacial surgery. We report a successful case of postoperative orocutaneous fistula closure using a VAC system in a 59-year male with a review of the relevant literature.

사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰 (Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients)

  • 안승권;김용배;이익재;송태수;손동민;장영재;조정희;김주호;김동욱;조재호;서창옥
    • Radiation Oncology Journal
    • /
    • 제26권3호
    • /
    • pp.189-194
    • /
    • 2008
  • 목 적: 본 연구팀은 사지에 발병한 카포시육종의 방사선치료를 위하여, 물볼루스를 사용할 수 있는 기구를 고안하였고, 쌀볼루스 사용시와 비교하여 유용성을 평가하고자 하였다. 대상 및 방법: 환자가 앙와위 자세에서 하지를 삽입 할 수 있는 폴리스틸렌 상자를 만들고 비닐 재질의 진공비닐을 집어 넣어 물이 누수 되지 않도록 결합하였으며, 진공비닐안에 하지와 물 사이의 공기를 없애기 위해 진공 밸브와 진공 펌프를 연결하여 공기를 제거하였다. 본 연구에서 제작한 물기반 볼루스의 선량 균질도를 비교 평가하기 위해 진공비닐에 하지 팬텀을 삽입한 후 폴리스틸렌 상자에 직접 쌀을 채운 경우, 비닐봉지에 쌀을 담아서 넣은 경우, 그리고 물을 직접 채운 경우에 대해 전산화단층촬영을 시행하였다. 방사선치료계획시스템을 사용하여 공기층의 부피에 의한 밀도의 변화를 분석하였다. 또한 선형가속기를 사용하여 전산화단층 모의치료기와 동일한 셋업에서 하지 팬텀에 필름을 감고, 열형광선량계 6개를 조사야 안에 균등하게 붙여서, 대향이문 조사하여 선량의 균질도 및 선량 값을 측정하였다. 결 과: 각 세 종류 실험의 밀도 측정결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 14% 감소했으며, 쌀을 비닐 봉지에 나누어 넣은 경우는 18% 감소하였다. 필름의 분석 결과 물볼루스가 쌀볼루스보다 균질도가 $4{\sim}4.4%$ 정도 우수한 것으로 나타났다. 열형광선량계 측정 평균값 분석결과 물볼루스를 기준으로 쌀을 직접 넣은 경우는 3.4% 증가했으며, 쌀을 비닐봉지에 나누어 넣은 경우는 4.3% 증가하였다. 결 론: 자체 제작한 물볼루스 기구는 육안으로 치료 조사야를 확인할 수 있어 셋업의 정확성을 높였으며, 진공 밸브와 진공 펌프를 사용하여 공기층을 감소시켜 치료의 정확성을 높이는 동시에 목적 종양에 균질도가 높은 선량을 부여 할 수 있는 좋은 방안이라 할 수 있다.

호흡 운동에 의한 내부 장기의 움직임 감소에 관한 연구 (A Study on the Reduction of Organ Motion from Respiration)

  • 김재균;이동한;이동훈;김미숙;조철구;류성렬;양광모;오원용;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.179-185
    • /
    • 2004
  • 선형 가속기를 통한 세기 변조절 방사선치료(Intensity Modulated Radiation Therapy, IMRT), IGRT, 3D-CRT (Three-Dimensional Conformal Radiotherapy) 및 사이버나이프를 통한 치료와 같은 3차원 방사선 치료에서 호흡에 의해 발생하는 종양의 움직임은 실제 치료에 있어 매우 중요한 요소이다. 이와 관련하여 움직이는 종양에 보다 정확한 방사선량을 조사시키기 위하여 ABC (Active Breathing Control), 호흡동기 방사선 치료 등의 여러 방법들이 사용되고 있다. 본 연구에서는 방사선 치료시 호흡에 따른 내부 장기의 움직임 감소 장치를 개발하여 내부 장기 중 횡격막 운동이 얼마나 효율적으로 감소하였는지에 대한 연구를 시행하였다. 4개의 벨트로 구성된 움직임 감소 장치를 환자에게 장착시키고, 환자의 복부 위에 작은 진공쿠션(Vaccum cusion)을 놓아 최대한 호흡을 내쉬게 한 후, 벨트로 환자의 횡격막 주위를 묶는 방법을 사용하였다 이때 횡격막에 움직임 감소 장치를 사용한 경우와 사용하지 않는 경우로 나누어 투시영상(fluoroscopy)에 나타난 횡격막의 움직임을 디지털 카메라 동영상 모드로 촬영하였다. 이 파일을 퍼스널 컴퓨터에 연결 후 포토샵 6.0 소프트웨어 프로그램을 통하여, 횡격막의 가장 높은 지점이 움직이는 최대점과 최소점을 관찰하여 횡격막 운동의 범위를 측정하였다. 움직임 감소장치를 사용하지 않은 경우 횡격막 움직임의 범위는 최소 1.14 cm에서 최대 3.14 cm였고, 그 평균값은 2.14 cm였다. 그러나 횡격막에 움직임 감소 장치를 사용한 결과 그 범위는 0.72~l.95 cm로, 평균값은 1.16 cm로 감소하였다. 횡격막 운동은 20~68.4% (평균 44.9%) 감소효과가 있었다. 횡격막 운동의 주기의 경우에는, 움직임 감소 장치를 사용한 결과 호흡 주기의 평균값이 4.4초에서 3.07초로 줄어들어 호흡이 빨라졌음을 확인할 수 있었다. 본 연구를 통하여 움직임 감소 장치를 사용함으로써 내부 장기 중 횡격막 움직임의 범위가 감소함과 동시에 CTV-PTV 마진이 크게 줄어드는 결과를 확인하였다. 이 결과를 통하여 흉부 또는 복부에 종양을 가진 환자 치료 시 더욱 질 높은 방사선 치료가 실현될 것으로 기대한다.

  • PDF

Pseudoaneurysm Leading to Necrotizing Fasciitis at the Femoral Arterial Puncture Site

  • Hong, Soo Chung;Choi, Hwan Jun;Kim, Yong Bae
    • Archives of Plastic Surgery
    • /
    • 제41권1호
    • /
    • pp.81-84
    • /
    • 2014
  • In this article, we present two cases of femoral pseudoaneurysm (PA) at the femoral arterial puncture site followed by necrotizing fasciitis, which is rare but can be fatal when not managed appropriately. PA was revealed by lower-extremity angiography and color-flow Doppler ultrasonography. Hematoma removal, thrombolysis, and bleeder ligation with Gelfoam were repeatedly performed by a vascular surgeon. When necrotizing fasciitis developed, aggressive surgical drainage and creation of a viable wound bed for reconstruction were mandatory. We adopted a vacuum-assisted closure device (Kinetics Concepts International) as the standard treatment for complicated, serious, infected PA of the puncture site. Excellent clinical outcomes were obtained.

Nanovesicles: Diagnostic and Therapeutic Tools in Nanoscale Medicine

  • Kim, Minji;Kim, Moonjeong;Kim, Kwang-sun
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.103-107
    • /
    • 2016
  • The use of nanovesicles (NVs) has contributed to nanotechnology in the development of new concept medicine to compete with diseases of deleterious and infectious to human health. Due to their properties of size, morphology, and biocompatibility NVs have great impact on public health especially in the development of new therapeutic and prophylaxis approaches in addition to the device for biosensors to diagnose human diseases. Recent data also strongly suggest that NVs are regarded as innovative materials in developing for vaccines and diagnostic tools. In this review, we focus on the basic concepts and recent applications of NVs to utilize or engineer them as therapeutic materials.

Teensy 마이크로 컨트롤러 기반 산소 유량 제어기 개발 및 성능평가 (Development and Evaluation of a Teensy Microcontroller-based O2 Mass Flow Controller)

  • 유민상;장연숙;김무환;조성보
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권4호
    • /
    • pp.193-200
    • /
    • 2021
  • Flowmeter and oxygen sensors are listed in COVID-19 essential medical devices. This article reports a Teensy microcontroller-based Oxygen mass flow controller (MFC), core part of the oxygen respirator or extracorporeal membrane oxygenation (ECMO). The developed MFC consisting of the microcontroller, MEMS flow sensor, and solenoid valve was able to accurately control 0 to 100 sccm of oxygen flow rate. The pressure of vacuum chamber increased proportionally to the flow rate (0.998 of Pearson correlation coefficient). The experimental results proved that the developed MFC exhibits comparable performance to a commercial MFC in accuracy, settling time, linearity with pressure, and repeatability of oxygen mass flow control. It is expected that this simple and cheap MFC is utilized for oxygen therapy against the severe acute respiratory syndrome coronavirus 2.

Integra®를 이용한 화상 반흔 구축 재건에 있어 Vacuum-Assisted Closure(VAC)의 유용성 (Acceleration of Integra Incorporation in Reconstruction of Burn Scar Contracture with The Vacuum-Assisted Closure(VAC))

  • 오석준;전만경;고성훈
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.432-436
    • /
    • 2009
  • Purpose: Negative pressure therapy has been used in various conditions to promote wound healing. It has also been used to secure a skin graft by improving microcirculation and improving tight adhesion between the graft and the recipient bed. To reduce post burn scar contracture and improve aesthetical result, many types of dermal substitutes have been invented and used widely. The goal of this study was evaluate usefulness of the VAC (Kinetic concepts Inc., San Antonio, TX) in improving the take rate and time to incorporation of Integra$^{(R)}$ in reconstruction of burn scar contracture. Methods: A retrospective study was performed from October, 2006 to December, 2008. The VAC was utilized for 11 patients. The average patient's age was 19.7 years (range 5 - 27) and average surface area was $785cm^2$ (range 24 - 1600). The burn scars were excised deep into normal subcutaneous tissue to achieve complete release of the scar, Integra$^{(R)}$ was sutured in place with skin staple와 Steri - strip$^{(R)}$. Then slit incisions were made on silicone sheet only with No.11 blade for effective drainage. The VAC was used as a bolster dressing over Integra$^{(R)}$. Negative - Pressure ranging from 100 to 125 mm Hg was applied to black polyurethane foam sponge trimmed to the appropriate wound size. An occlusive seal over the black polyurethane foam sponge was maintained by a combination of the occlusive dressing, OP - site$^{(R)}$. The VAC dressing changes were performed every 3 or 4 days until adequate incorporation was obtained. The neodermis appeared slightly yellow to orange color. When the Integra$^{(R)}$ deemed clinically incorporated, The VAC was removed and take was estimated with visual inspection. Very thin STSG(0.006 ~ 0.008 inches) was performed after silicone sheet removal. Result: The mean time for clinically assessed incorporation of Integra$^{(R)}$ was 10.00 days (range 9 - 12). The mean dressing change was 3.5 times until take was obtained. In All patients, Integra$^{(R)}$ had successful incorporation in tissue without serious complications. Conclusion: Integra$^{(R)}$ in combination with Vacuum - Assisted Closure(VAC) may be incorporated earlier than conventional dressing method.

간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가 (Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy)

  • 오병천;최태규;김기철
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.11-18
    • /
    • 2010
  • 목 적: 방사선 치료에서 매번 치료를 시행할 때마다 호흡에 의한 해부학적인 내부 장기의 움직임과 환자자세의 변화에 따라 치료부위 오차가 발생한다. 이런 치료부위 오차의 발생은 치료부위와 정상 조직 간의 선량분포의 변화에 영향을 줄 수 있는 원인이 된다. 간암 환자 치료 시 Body-fix의 사용 유무 차이에 따른 임상치료에서의 유용성을 알아보고자 한다. 대상 및 방법: 본원에서 2009년 10월부터 2010년 7월까지 Hi-Art Tomotherapy를 시행 받은 55~60세 사이의 남자환자 중에서 간의 Couinaud 분류 중 V~VI 구역에서 간세포성 암(Hepatocellular carcinoma)이 발생한 환자 10명을 대상으로 Body-fix 사용 유무에 따라 2 그룹으로 분류하여 조사하였다. Body-Fix를 사용 시 진공펌프(Vacuum pump, Medical intelligence, Germany)를 이용하여 80 mbar의 압력으로 진공상태를 유지하였다. 환자는 정상호흡(free breathing)을 유지한 상태에서 바로누운자세(supine position)로 치료 시작부터 5회 치료 시 획득한 MV-CT (Megavoltage computed tomograpy, MVCT)와 KV-CT(Kilovoltage computed tomograpy, KVCT)을 융합하여 일치시키는 작업 후 X축의 좌우방향(Right to Left, RL), Y축의 상하방향(Craniocaudal, CC), Z축의 전후방향(Anterioposterior, AP)에서의 발생하는 방사선 치료 준비오차를 측정하여 비교 분석하였다. 결 과: 영상융합을 통한 평균 방사선 치료 준비오차는 A 그룹에서 $0.3{\pm}1.1\;mm$ (상하), $-1.1{\pm}0.7\;mm$ (좌우), $-0.2{\pm}0.7\;mm$ (전후)이었다. B 그룹에서는 $0.62{\pm}1.94\;mm$ (상하), $-3.62{\pm}1.5\;mm$ (좌우), $-0.22{\pm}1.2\;mm$ (전후)로 이동하였다. 두 그룹간의 Body-fix의 사용유무에 따른 X축, Y축, Z축 방향의 편차는 최대 X축(좌우) 5.5 mm, Y축(상하) 19.8 mm, Z축(전후) 3.2 mm로 측정되었다. 또한 오차방향의 분석과 관련하여 모든 환자에 일관성이 존재하지는 않지만 Body-Fix를 사용 시 매일 환자자세 변화와 호흡변화가 발생함에도 불구하고 방사선 치료 준비오차에 대한 위치 변화가 안정적인 양상의 결과를 보여준다. 결 론: 간암 환자 치료 시 Body-Fix의 사용은 방사선 치료 준비오차가 환자자세와 호흡변화에도 불구하고 각 그룹간의 편차가 발생하는 가운데에 안정적이며 규칙적이므로 Tomotherapy와 같은 고 정밀 치료에 효과적으로 사용되리라 사료된다.

  • PDF

하행 괴사성 종격동염의 치험례 (A Case of Descending Necrotizing Mediastinitis)

  • 이인수;최환준;이한정;이재욱;이동기
    • Archives of Plastic Surgery
    • /
    • 제36권3호
    • /
    • pp.351-355
    • /
    • 2009
  • Purpose: Cervical necrotizing fasciitis tends to involve the deep soft tissues and spread caudally to the anterior chest and mediastinum, often resulting in major complications and death. It may rapidly spread into the thorax along fascial planes, and the associated diagnostic delay results in this descending necrotizing mediastinitis. So, aggressive multidisciplinary therapy with surgical drainage is mandatory. We present a very rare case of descending necrotizing mediastinitis with literature review. Methods: A 53 years old male visited our department 7 days after trauma in neck. His premorbid conditions and risk factors of necrotizing fasciitis were concealed hepatoma, trauma history, chronic liver disease, and nutrition deficit. Computed tomographic scans of the head and neck region were performed in this patient : signs of necrotizing fasciitis, were seen in the platysma, sternocleidomastoid, trapezius muscle and strap muscles of the neck. Fluid accumulations involved multiple neck spaces and mediastinum. At the time, he diagnosed as necrotizing fasciitis on his neck and anterior chest. Necrotic wound was excised serially and we treated this with the Vacuum - assisted closure(VAC, Kinetics Concepts International, San Antonio, Texas) system device. After appropriately shaping the sponge and achieving additional 3 pieces drainage tubes in the pockets, continuous negative pressure of 125 mmHg was applied. The VAC therapy was utilized for a period of 12 days. Results: We obtained satisfactory results from wide excision, abscess drainage with the VAC system, and then split thickness skin graft. The postoperative course was uneventful. Conclusion: The refined technique using the VAC system can provide a means of simple and effective management for the descending necrotizing mediastinitis, with better cosmetic and functional results. Finally, the VAC system has been adopted as the standard treatment for deep cervical and mediastinal wound infections as a result of the excellent clinical outcome.