• Title/Summary/Keyword: Vacuum pressure difference

Search Result 100, Processing Time 0.023 seconds

Repair of Plasma Damaged Low-k Film in Supercritical Carbon Dioxide (초임계이산화탄소를 이용한 플라즈마 손상된 다공성 저유전 막질의 복원)

  • Jung, Jae-Mok;Lim, Kwon-Taek
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.191-197
    • /
    • 2010
  • Repair reaction of plasma damaged porous methyl doped SiOCH films was carried out with silylation agents dissolved in supercritical carbon dioxide ($scCO_2$) at various reaction time, pressure, and temperature. While a decrease in the characteristic bands at $3150{\sim}3560cm^{-1}$ was detectable, the difference of methyl peaks was not identified apparently in the FT-IR spectra. The surface hydrophobicity was rapidly recovered by the silylation. In order to induce effective repair in bulk phase, the wafer was heat treated before reaction under vacuum or ambient condition. The contact angle was slightly increased after the treatment and completely recovered after the subsequent silylation. Methyl groups were decreased after the plasma damage, but their recovery was not identified apparently from the FT-IR, spectroscopic ellipsometry, and secondary ion mass spectroscopy analyses. Furthermore, Ti evaporator was performed in a vacuum chamber to evaluate the pore sealing effect. The GDS analysis revealed that the open pores in the plasma damaged films were efficiently sealed with the silylation in $scCO_2$.

Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure (유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과)

  • Ryu, Young Hyo;Uhm, Han Sup;Park, Gyung Soon;Choi, Eun Ha
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.55-65
    • /
    • 2013
  • Sterilization of Neurospora crassa has been investigated in this research by using a surface air plasma with dielectric barrier discharged (DBD) structure under atmospheric pressure. The sinusoidal alternating current has been used in this experiment with discharge voltage of 1.4~2.3 kV. The phase difference between the voltage and current signals are found to be almost 80 degree due to the capacitive property of dielectric barrier. Temperature on the biomaterials has been minimized by radiating the heat with the air cooling system. It is noted that the substrate temperature remains under 37 degree for plasma exposure time of 10 minutes with operation of cooler system. It is found that the ozone, $O_3$, has been measured to be about 25~30 ppm within 1 cm region and to be about 5 ppm at the 150 cm downstream region away from the suface plasma. It is also noted that the nitric oxide, NO, and nitric dioxide, $NO_2$, are not nearly detected. Germination rate and mitochodrial activity of Neurospora crassa immersed in the deionized water have been found to be drastically decreased as the plasma treatment time and its electrical power are increased in this experiment. Here, the mitochondrial activity has been analyzed by MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) assay. However, sterilization of Neurospora crassa immersed in the Vogel's minimal media has been found to be low by plasma treatment, which is caused by surrounding background solution. This research shows the sterilization possibility of Neurospora crassa by using the noncontated surface DBD plasma, which is different from the plasma jet. This is mainly attibuted to the reactive species generated by the surface plasma, since they play a major role for inhibition of micobes such as Neurospora crassa.

The Effect of Deposition Parameters on the Morphology of KLN Thin Films (증착 조건이 KLN 박막의 형상에 미치는 영향)

  • Park, Seong-Geun;Jeon, Byeong-Eok;Kim, Jin-Su;Kim, Ji-Hyeon;Choe, Byeong-Jin;Nam, Gi-Hong;Ryu, Gi-Hong;Kim, Gi-Wan
    • Korean Journal of Materials Research
    • /
    • v.11 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • The growth characteristics of 4-fold grain which was appeared in KLN deposition on $Pt/Ti/SiO_2/Si(100)$ substrate was studied by varying process variables. Substrate temperature, sputtering pressure, rf power were selected as process variables, and experiment was carried out near optimum fabrication condition. When using K and Li enriched target, the optimum fabrication conditions were substrate temperature of $600^{\circ}C$, sputtering pressure of 150mTorr, rf power of 100 W and its surface morphology is sensitively varied by small deposition condition changes. KLN is composed of elements which have large difference of boiling point. And it is difficult to fabricate thin film at high temperature and high vacuum deposition condition. Furthermore the phenomenon during deposition process can not be explained by using Thorton's model which explains the relation between thin film structure and melting point of thin film materials. These phenomenon can be explained using boiling point of elements which consist of thin film material.

  • PDF

Effect of High Pressure after the Addition of Vegetable Oil on the Safety and Quality of Beef Loin (식물성 유지 첨가 후 초고압 처리가 우육의 안전성 및 육질에 미치는 영향)

  • Jung, Yeon-Kook;Jung, Samooel;Lee, Hyun-Jung;Kang, Min-Gu;Lee, Soo-Kee;Kim, Yun-Ji;Jo, Cheorun
    • Food Science of Animal Resources
    • /
    • v.32 no.1
    • /
    • pp.68-76
    • /
    • 2012
  • Olive oil and grape seed oil (10% of meat weight) were added to a package of beef loin. The package was then vacuum-sealed, and high pressure was applied (HP, 600 MPa) to investigate the effect of the penetration of vegetable oil into meat and safety and quality of the meat. Non-HP (0.1 MPa) without any oil treatment was considered as a control. The color $L^*$ and $b^*$-values of beef loin were higher and the $a^*$-value was lower than those of the control after HP at 600 MPa. The total aerobic bacterial number was 3 Log CFU/g in the control but no viable cell was detected in the beef with 600 MPa. All inoculated E. coli and L. monocytogenes were inactivated by HP. The beef loin with vegetable oil added without HP did not show any difference in fatty acid composition, but that treated by HP showed a higher oleic and linoleic acid content when olive oil and grape seed oil were added, respectively. The addition of olive oil inhibited lipid oxidation, and sensory evaluation revealed that there was no difference among treatments. The results indicate that the addition of vegetable oil followed by the application of HP enhances the safety of beef loin, changing the fatty acid composition in a health beneficial way. In addition, the use of olive oil can inhibit lipid oxidation induced by HP.

Microstructure of ZnO Thin Film on Nano-Scale Diamond Powder Using ALD (나노급 다이아몬드 파우더에 ALD로 제조된 ZnO 박막 연구)

  • Park, S.J.;Song, S.O.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.538-543
    • /
    • 2008
  • Recently a nano-scale diamond is possible to manufacture forms of powder(below 100 nm) by new processing of explosion or deposition method. Using a sintering of nano-scale diamond is possible to manufacture of grinding tools. We have need of a processing development of coated uniformly inorganic to prevent an abnormal grain growth of nano-crystal and bonding obstacle caused by sintering process. This paper, in order to improve the sintering property of nano-scale diamond, we coated ZnO thin films(thickness: $20{\sim}30\;nm$) in a vacuum by ALD(atomic layer deposition) Economically, in order to deposit ZnO all over the surface of nano-scale diamond powder, we used a new modified fluidized bed processing replaced mechanical vibration effect or fluidized bed reactor which utilized diamond floating owing to pressure of pulse(or purge) processing after inserted diamond powders in quartz tube(L: 20 mm) then closed quartz tube by porosity glass filter. We deposited ZnO thin films by ALD in closed both sides of quartz tube by porosity glass filter by ALD(precursor: DEZn($C_4H_{10}Zn$), reaction gas: $H_2O$) at $10^{\circ}C$(in canister). Processing procedure and injection time of reaction materials set up DEZn pulse-0.1 sec, DEZn purge-20 sec, $H_2O$ pulse-0.1 sec, $H_2O$ purge-40 sec and we put in operation repetitive 100 cycles(1 cycle is 4 steps) We confirmed microstructure of diamond powder and diamond powder doped ZnO thin film by TEM(transmission electron microscope) Through TEM analysis, we confirmed that diamond powder diameter was some $70{\sim}120\;nm$ and shape was tetragonal, hexagonal, etc before ALD. We confirmed that diameter of diamond powders doped ZnO thin film was some $70{\sim}120\;nm$ and uniform ZnO(thickness: $20{\sim}30\;nm$) thin film was successfully deposited on diamond powder surface according to brightness difference between diamond powder and ZnO.

The Influence of Feeding Dietary Differences on Growth Performance and Carcass Quality in Finishing Pigs (사료조성 차이가 돼지 생산 및 도체형질에 미치는 영향)

  • 진상근;김일석;송영민;하경희;이성대;김회윤;주선태;박구부
    • Food Science of Animal Resources
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2003
  • All diets were based on feeds of fattening period pigs(LY x D, ca. 90 kg) with six treatments, which were the control, containing 5% beef tallow(C), 3% beef tallows and 2% perilla seeds oil(T1), 250 ppm vit. E(${\alpha}$-tocopheryl acetate) in T1(T2), 3% beef tallow and 2% squid viscera oil(T3), 250 ppm vit. E in T3(T4), and 3% beef tallow and 2% CLA(T5), respectively. Produced porks and their carcass characteristics were as follows. The daily gain of pigs was higher in T2 and 73 than any other treatments(p<0.05). Its T2 and T3 was 3.71 and 3.80 respectively, however, there was no significance in feed intake. The highest back fat thickness was shown in control group on market weight, while there was no significant difference on their initial weight. Loin-eye muscle area did not show any significant difference on initial weight and on market weight, however, its T5 was about twice as large as T2's. Content of triglyceride in blood was high in control group as compared to others; especially, the values for T3, T4 and T5 were significantly low(p <0.05). There was no significant difference in total cholesterol contents, and the ratio of HDL cholesterol/total cholesterol was higher in vit. E treated samples than untreated sample. Atherogenic index was high in sample with T3 and low in sample with T2. The perilla seed oil, squid fish oil, and vit. E decreased atherogenic index. Dressing percentage, back fat thickness, and grade did not show any significant difference(p >0.05); however, T2, C and T3, T1 and T5 showed 4.67, 4.29, 4.00 respectively, in grades.

Gas Permeation Properties of Polymeric Membranes for Biosensor Prepared from Poly(vinyl chloride) Derivatives (Poly(vinyl chloride) 유도체로부터 제조된 바이오센서용 고분자막의 기체 투과특성)

  • Lim, Chun-Won;Kim, Wan-Young;Lee, Youn-Sik;Yoon, Jeong-Won;Jeong, Yong-Seob
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.362-366
    • /
    • 1999
  • Membranes for biosensor were prepared from poly(vinyl chloride) (PVC)l derivatives using the solution casting method, and their gas permeabilities were studied. The polymer membranes dried slowly in air showed higher permeability coefficients than those dried in vacuum. The permeabilily coefficients of carboxylated poly(vinyl chloride) (CPVC) membranes for $O_2$ and $CO_2$ decreased as the pressure of the feed gas increased. The addition of dioctylphthalate (DOP) enhanced the permeation rates for $O_2$ and $CO_2$. For example, the permeability coefficients of CPVC membranes containing 30 wt. % DOP for $O_2$ and $CO_2$ at 100 psig were 2.03 and 0.96 Barrer, respectively, which were about 4~5 times higher than those of the membranes without DOP. Poly(vinyl chloride-co-vinyl acetate-co-vinyl alcohol) (Syn-PVCAcAl) obtained by hydrolysis of poly(vinyl chloride-co-vinyl acetate (PVCA) showed a higher permeability coefficient for $CO_2$ in the presence of DOP than that for commercial PVCAcAl, but did not show any significant difference in permeability for $O_2$.

  • PDF

Effect of Aromatic Additives on the Coke Reduction and the Asphaltene Conversion in a Slurry-phase Hydrocracking (슬러리상 수첨분해 반응에서 아로마틱 유분 첨가에 따른 코크 저감 및 아스팔텐 전환 특성)

  • Lim, Suk Hyun;Go, Kang Seok;Nho, Nam Sun;Lee, Jae Goo
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.244-252
    • /
    • 2019
  • This study investigated the effect of addition of aromatics such as Toluene/LCO/resin on the coke depression and asphaltene conversion. The experiment was carried out with vacuum residue as a feedstock with Molybdenum dispersed catalysts under the slurry-phase hydrocracking condition (Temp. of $425^{\circ}C$, $H_2$ pressure of 80 bar at $80^{\circ}C$, reaction time of 4 hr, Mo-concentration of 500 ppm). As results, the coke reduction was shown to be similar irrespective of types of aromatics, while asphaltene was more converted to gas and maltene when LCO and resin with higher dipole moment were added. The addition of aromatics with change of reaction time showed no difference in terms of depression of coke formation. But the addition of LCO rather increased the coke yield after 2 hr. And it was found that asphaltene in liquid phase had the higher aromaticity index so that asphaltene is difficult to disperse in oil phase.

Effects of Cooking Method and Temperature on the Lipid Oxidation of Electron-Beam Irradiated Hanwoo Steak. (가열방법 및 온도가 전자선 조사한 한우 steak의 지질산화에 미치는 영향)

  • Park T. S.;Shin T. S.;Lee J. I.;Park G. B.
    • Journal of Life Science
    • /
    • v.15 no.5 s.72
    • /
    • pp.840-846
    • /
    • 2005
  • This study was carried out to investigate the effect of electron beam irradiation and cooking temperature on physico-chemical characteristics and lipid oxidation of beef. A total of six beef carcasses ($280\∼300 kg$) that were quality grade $1^{+}$(marbling score No.7, meat color No.4, maturity No.1, texture No.1) was purchased at the commercial slaughter house. The carcasses were transported and washed using high pressure water, and pasteulized with $ 50\% $ ethyl alcohol in the laboratory. After the carcasses were deboned and trimmed, loin and round were taken out to make steak (1.5cm thickness) or ground beef respectively. Samples were wrap or vacuum packaged and irradiated with 0, 3, 4.5, 6 and 7.5 kGy using electron-beam accelerator at Samsung Heavy Industries Ltd. Co. (in Taejun). Irradiated samples were cooked with different methods(electronic pan and gas oven) and temperatures ($ 60^{\circ}C, 70^{\circ}C and 80^{\circ}C$) and used to measure fatty acid composition, TBARS, cholesterol oxide products and panel test scores. The content of saturated fatty acids increased by increasing heating temperature in oven boiling steak (OBS) and pan boiling steak (PBS), and there was no difference by electron-beam irradiation. Both irradiated and non-irradiated treatment were high as the heating temperature increased in TBARS by heating temperature in PBS (p < 0.05) and the amount of Malonaldehyde (MA), standard of fat deterioration, was increased in OBS (p < 0.05). Non-irradiated and 3, 6 kGy treatment produced about 2 fold amount of MA at $ 60^{\circ}C $ compared with $ 80^{\circ}C $. In comparison with PBS, OBS produced much amount of MA and a bit different from non-irradiated treatment but did not show no tendency. As irradiation levels and heating temperature increased, the amount of cholesterol oxides products was increased and also pan-heating method, direct heating method, significantly increased the degree of oxidation compared with oven-heating method, indirect heating method (p < 0.05).

Improvement of Oxygen Isotope Analysis in Seawater samples with Stable Isotope Mass Spectrometer (질량분석기를 이용한 해수 중 산소안정동위원소 분석법의 개선)

  • Park, Mi-Kyung;Kang, Dong-Jin;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.4
    • /
    • pp.348-353
    • /
    • 2008
  • Oxygen isotope has not been used actively in water mass studies because of difficulties on the analysis though it has advantages as a water mass tracer. The most popular method to analysis the oxygen isotope ratio in water samples is equilibration method: isotopic equilibrium of water with $CO_2$ at constant temperature. The precision of oxygen isotope analysis using commercial automatic $H_2O/CO_2$ equilibrator is ${\pm}0.1%o$. This value is not sufficient for studies in open ocean. The object of this study is to improve the analytical precision enough to apply open ocean studies by modification of the instrument. When sample gas is transferred by the pressure difference, the fractionation which is preferential transportation of light isotope can be occurred since the long transportation path between the equilibrator and mass spectrometer. And the The biggest source of error during the analysis is long distance and large volume of the pathway of sample gas between. Therefore, liquid nitrogen trap and high vacuum system are introduced to the system. The precisions of 14 time analysis of same seawater sample are ${\pm}0.081%o$ and ${\pm}0.021%o$ by built-in system and by modified system in this study, respectively.