• Title/Summary/Keyword: Vacuum gauge

Search Result 75, Processing Time 0.027 seconds

Development of an Automatic Refrigerant Charging Device for Refrigeration Applications (냉동기용 자동 냉매 충전장치 개발)

  • 김성수;윤희정;홍희기;강용태
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.253-258
    • /
    • 2003
  • Manual type manifold gauge has been used for charging the refrigerant in the refrigeration systems. In this case, the refrigerant is released to the ambient during the hose-switching period. :he objectives of this study are to develop a novel automatic refrigerant charging system, and to quantify the effect of the automatic systems on the reduction of the non-condensable gas and the contamination of the compressor oil. The automatic charging system makes the pressure test, vacuum test, and refrigerant charging work very simple and easy because the charging hose does not have to be switched many times. It is found that the amount of water in the SiO$_2$and the compressor oil reduces to l/4 times of that for the manual type manifold gauge and the refrigerant is not released to the ambient at all when the automatic charging system is adopted.

Effects of Storage Temperature and Packaging Methods on the Quality of Raw and Boiled Vegetable Peanut (저장온도 및 포장방법이 풋땅콩 품질에 미치는 영향)

  • 최윤희;정영근;박기훈;김영두
    • Food Science and Preservation
    • /
    • v.9 no.3
    • /
    • pp.267-270
    • /
    • 2002
  • This study was carried out to establish storage methods and to keep high quality of the raw and boiled vegetable peanut. After boiling at 100$^{\circ}C$ for 20min at 7% saline water far 40min the pods were packaged with 80 $\mu\textrm{m}$ Ny/LDPE film in vacuum, 80$\mu\textrm{m}$ LDPE film and Gauge-bag, and stored at room temperature and 4$^{\circ}C$. The moisture content of pods in room temperature were decreased than pods at 4$^{\circ}C$. After 21days storaging with Gauge-bag, texture of pods were toughen because moisture content of pods reduced severely. Colour of raw pods in packaging 80 $\mu\textrm{m}$ Ny/LDPE film vacuum was severely browning but boiled pods was browning little after opening a seal. After 2days storage at room temperature and 21days storage at 4t, pods were deteriorated. The hardness was much lower in boiled kernels than raw kernels and decreased when the storage period elapsed.

The Prediction of Self-life on Functional Beverage (기능성 음료의 유통기간 예측)

  • Lee Gee-Dong;Kim Jung-Ok;Kim Min-Sun;Lee Kang-Pyo
    • Food Science and Preservation
    • /
    • v.13 no.2
    • /
    • pp.154-160
    • /
    • 2006
  • Shelf-life of functional beverage for the purpose of body fat reduction during storage was estimated at different temperatures. To estimate quality change of functional beverage, vacuum gauge, sugar concentration pit acidify, Hunter's color value, browning color intensity, total cell count and sensory evaluation were measured periodically. Vacuum gauge, sugar concentration pH and acidity were little changed and total cell count was not detected. By using the correlation coefficient between sensory evaluation and physicochemical properties, b-value was chosen for quality index of functional beverage. $Q_{10}-values$ for shelf-life were in the range of $2.13{\sim}2.59$. When sensory evaluation was 2.5 at $50^{\circ}C$, storage period was 6.83 weeks. And shelf-life calculated by $Q_{10}-values$ were 73.89, 34.21 and 13.21 weeks in $20^{\circ}C,\;30^{\circ}C\;and\;40^{\circ}C$, respectively.

Measurement of CTE Change in a Composite Laminate with Aging under Space Environment using Fiber Optic Sensors (광섬유센서를 이용한 우주환경하에서 복합재료 적층시편의 노화에 따른 열팽창계수변화 측정)

  • Gang,Sang-Guk;Gang,Dong-Hun;Kim,Cheon-Gon;Hong,Chang-Seon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.21-26
    • /
    • 2003
  • In this research, the change of coefficient of thermal expansion (CTE) of graphite/epoxy composite laminate under space environment was measured using fiber optic sensors. Two fiber Bragg grating (FBG) sensors have been adopted for the simultaneous measurement of thermal strain and temperature. Low Earth Orbit (LEO) conditions with high vacuum, ultraviolet and thermal cycling environments were simulated in a thermal vacuum chamber. As a pre-test, a FBG temperature sensor was calibrated and a FBG strain sensor was verified through the comparison with the electric strain gauge (ESG) attached on an aluminun specimen at high and low temperature respectively. The change of the CTE in a composite laminate exposed to space environment was measured for intervals of aging cycles in real time. As a whole, there was no abrupt change of the CTE after 1000 aging cycles. After aging, however, the CTE decreased a Little all over the test temperature range. These changes are caused by outgassing, moisture desorption, matrix cracking etc.

Examination of the Impact of Substituting Germanium for Bismuth on the Energy Density and Electrical Conductivity of the Se60Ge40-xBix Alloy

  • Kareem Ali Jasim;Haider Sahi Hussein;Shaymaa Hashim Aneed;Ebtisam Mohammed Taqi Salman
    • Korean Journal of Materials Research
    • /
    • v.34 no.6
    • /
    • pp.267-274
    • /
    • 2024
  • In this study, four different samples of Se60Ge40-xBix chalcogenides glasses were synthesized by heating the melt for 18 h in vacuum Pyrex ampoules (under a 10-4 Torre vacuum), each with a different concentration (x = 0, 10, 15, and 20) of high purity starting materials. The results of direct current (DC) electrical conductivity measurements against a 1,000/T plot for all chalcogenide samples revealed two linear areas at medium and high temperatures, each with a different slope and with different activation energies (E1 and E2). In other words, these samples contain two electrical conduction mechanisms: a localized conduction at middle temperatures and extended conduction at high temperatures. The results showed the local and extended state parameters changed due to the effective partial substitution of germanium by bismuth. The density of extended states N(Eext) and localized states N(Eloc) as a function of bismuth concentration was used to gauge this effect. While the density of the localized states decreased from 1.6 × 1014 to 4.2 × 1012 (ev-1 cm-3) as the bismuth concentration increased from 0 to 15, the density of the extended states generally increased from 3.552 × 1021 to 5.86 × 1021 (ev-1 cm-3), indicating a reduction in the mullet's randomness. This makes these alloys more widely useful in electronic applications due to the decrease in the cost of manufacturing.

Separation of Nitric Acid and Acetic Acid from the Waste Acid in LCD Etching Process (LCD 식각폐액으로부터 질산과 초산의 분리)

  • Chun, Hee-Dong;Roh, Yu-Mi;Park, Sung-Kuk;Kim, Ju-Han;Shin, Chang-Hoon;Kim, Ju-Yup;Ahn, Jae-Woo
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.123-128
    • /
    • 2008
  • The waste solution, which was discharged from the recovery process of LCD etching solution, consists of 15 wt% nitric acid and 20 wt% acetic acid. In this study, it was conducted to separate acid individually from the mixed acid by vacuum evaporation under -760 mmHg gauge and at $40^{\circ}C$. We have investigated evaporation behavior of acid as a function of temperature. There have been problems that tiny amount of nitric acid were evaporated simultaneously above $33^{\circ}C$. Thus, efforts were conducted to recover acetic acid by vacuum evaporation with adding $H_2O$, waste mixed acid and 20 g/L NaOH for a curb on evaporation of nitric acid. By adding $H_2O$, evaporation of nitric acid was reduced from 7% to 0.78%. However, it was reduced from 7% to 0.25% by adding mixed acid. In view of the results achieved so far, we may expect to separate the etching solution individually by controlling vacuum conditions.

  • PDF

Thermal Expansion Coefficient Measurement of STS430 by Laser Speckle Interferometry (레이저 스페클간섭법에 의한 STS430의 열팽창계수 측정)

  • 김경석;이항서;정현철;양승필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.29-33
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,000$^{\circ}C$. Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 800$^{\circ}C$. There needs to measure the data up to 800$^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000$^{\circ}C$. In previous studies related to thermal strain analysis, the quantitative results are not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,000$^{\circ}C$and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow 600$^{\circ}C$ however, there is some difference up to 600$^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 800$^{\circ}C$. The reason is the phase transformation of STS430 probably begins at 800$^{\circ}C$.

  • PDF

Thermal Expansion Coefficient Measurement of STS430 at High Temperature by In-plane ESPI (In-plane ESPI를 이용한 고온에서 STS430의 열팽창계수 측정)

  • 김경석;강기수;장호섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.69-74
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,00$0^{\circ}C$ . Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 80$0^{\circ}C$ . There needs to measure the data up to 80$0^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000'E In previous studies related to thermal strain analysis, the quantitative results have not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,00$0^{\circ}C$ and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow $600^{\circ}C$ however, there is some difference up to $600^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 80$0^{\circ}C$ . The reason is the phase transformation of STS430 probably begins at 80$0^{\circ}C$

Fabrication and Characterization of Transparent Piezoresistors Using Carbon Nanotube Film (탄소나노튜브 필름을 이용한 투명 압저항체의 제작 및 특성 연구)

  • Lee, Kang-Won;Lee, Jung-A;Lee, Kwang-Cheol;Lee, Seung-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1857-1863
    • /
    • 2010
  • We present the fabrication and characterization of transparent carbon nanotube film (CNF) piezoresistors. CNFs were fabricated by vacuum filtration methods with 65?92% transmittance and patterned on Au-deposited silicon wafer by photolithography and dry etching. The patterned CNFs were transferred onto poly-dimethysiloxane (PDMS) using the weak adhesion property between the silicon wafer and the Au layer. The transferred CNFs were confirmed to be piezoresistors using the equation of concentrated-force-derived resistance change. The gauge factor of the CNFs was measured to range from 10 to 20 as the resistance of the CNFs increased with applied pressure. In polymer microelectromechanical systems, CNF piezoresistors are the promising materials because of their high sensitivity and low-temperature process.

Effect of Ovum Pick-up Frequency on In Vitro Production of Embryos in Hanwoo Cattle (한우에 있어서 초음파기기를 이용한 생체내 개체별 난자 채취 빈도 및 수정란 생산효율에 관한 연구)

  • 박성재;양보석;임기순;성환후;양병철;장원경;정일정;정기화;심보웅
    • Journal of Embryo Transfer
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2000
  • The ultrasound-guided oocytes cllection (ovum pick-up ; OPU) has become a substitution for superovlation in cattle. The objective of this study was to examine the effect of OPU frequency on the in vitro production of embryos in Hanwoo cattle. Six cycling Hanwoo cows were distributed into two groups for either once or twice weekly OPU sessions. Oocytes were collected by ultrasound-guided follicle aspiration(SA600) using a 6.5HMz transducer and attached with 18 gauge needle, with vacuum pressure of 40 mmHg. The cumulus-oocyte complexes (COCs) collected from each donor were matured in TCM 199 supplemented with 10% fetal bovine serum at 5% CO2 in air at 38.5$^{\circ}C$ for 22h and in vitro matured oocytes were co-incubated with sperm(separated by Percoll gradient) for 6h. The zygotes were co-cultured on cumulus cell monolayer in 10ul droplets in the same culture medium and conditions used for IVM for 7 days. On Day 7 of culture, development to blastocysts was examined. Although the number of oocytes collected was variable depending on individuals, overall embryo production in the twice per week OPU sessions was better that in the once per week sessions(6~21 vs 2~7 blastocysts produced, respectively). Two cows(E, A) were good oocyte donors and embryo production was superior in cow C ; however, cow F was a poor donor as compared to the others. In conclusion, these results suggest that for embryo production, twice weekly OPU sessions were better than once per week for producing embryos in vitro from Hanwoo cattle.

  • PDF