• Title/Summary/Keyword: Vacuum Evaluation

Search Result 386, Processing Time 0.029 seconds

Defects Evaluation of Blue Light Emitting Materials by Wet Etching and Transmission Electron Microscoppy

  • Hong, Soon-Ku;Kim, Bong-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.105-106
    • /
    • 1998
  • Evaluation of def3ects by etch-ppit formation was studied. A NaOH(30 mol%) etchant was found useful for etch-ppit developpment on ZnSe-based eppilayers grown on (001) gaAs. And a H3ppO4(85 mol%) was used in order to developp etch-ppits on GaN-base eppilayers grown on (0001) Al2O3 After etch-ppit formation on the surfsce. Transmission Electron Microscoppy(TEM) was cppmdicted. By etch-ppit developpment and TEM observation we could determine the defect typpes by etch-ppit configurfations and found origin of etch-ppit in the cse of ZnSe-based materials. Based uppon these results we can do defect identification by etch-ppit test simpply. In the case of GaN-based materials we could evaluate nanoppippe density. however high density of threading dislocations in GaN eppilayers were not revealed by etch-ppit developpment. Based uppon these results we can evaluate the nanoppippe density which difficult to evaluate using TEM beacause of its small size(diameter). And at ppresent status direct matching of etch-ppit density to dislocation density would make severe mistake.

  • PDF

Development of Uncertainty Evaluation Model for Vacuum Measurement Standards (진공측정표준의 불확도 평가모델 개발)

  • Hong, S.S.;Lim, J.Y.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.5
    • /
    • pp.313-321
    • /
    • 2011
  • The Korea Research Institute of Standards and Science (KRISS) has three major vacuum systems: an ultrasonic interferometer manometer (UIM), a static volume expansion system (SVES), and an orifice-type dynamic expansion system (ODES). For each system explict measurement model equations with multiple variables are respectively given. According to ISO standards, all these system variables errors were used to calculate the expanded uncertainty (U).

A Study on the Effect of the Contact Electrode Slits in the Vacuum Interrupter with Axial Magnetic Field Type (종자계형 진공 인터럽터에서 접점전극 슬릿의 영향에 관한 연구)

  • 하덕용;강형부;최승길;최경호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.9
    • /
    • pp.822-829
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density for each slits made on the contact electrode in the vacuum interrupter with axial magnetic field type using 3-dimension finite element analysis. It has been known that the presence of an axial magnetic field parallel to the current flow in the arc plasma can increase the high current breaking capacity of vacuum interrupter by carrying out the arc plasma from constricted mode to diffusion mode. The axial magnetic field is created of itself by current flow in the segments of coil electrode behind the contact electrode. The analyzed results show that if the slits are made in the contact electrode, they can increase the current density and axial magnetic flux density in the contact electrode surface and at the gap distance, which is due to decrease the effect of eddy currents flowing in the contact electrode. The phase shift due to eddy currents, defined 3s time difference between the maximum value of current and axial magnetic field, is decreased still more by increasing the number of slits made in the contact electrode at the center point of gap distance. These results demonstrate that 3-dimension finite element analysis has a great deal of merits in the development and evaluation of new electrode at the design of vacuum interrupter.

Operating Characteristics of Low Vacuum Pumps (저진공 펌프의 운전 특성)

  • 임종연;심우건;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.93-104
    • /
    • 2003
  • For evaluation of durability of low vacuum pumps, it is required to examine the performance and degradation of low vacuum pumps. Pump degradation may result from abnormalities associated with the performance in many areas of pump operation. The diagnostics method can be used to monitor the pump performance in the semi-conductor process line. Based on the mechanical defect of the pump, the dynamic response and reliability of the system for performance test, and the dynamic characteristics of the pump were experimentally assessed. The theoretical work rate for the compression process in the pump was calculated, and then the efficiency of the pump associated with the power consumption was evaluated. This analysis will be useful in detecting pump degradation with increasing the power consumption. To determine the predominant factors of pump degradation, it is important to evaluate the entire pumping system. We studied vibration, dynamic pressure, pumping speed, and power consumption of low vacuum pumps. Our results can be utilized for the future research on the evaluating technology of durability of low vacuum pumps.

Effect of Chlorine Dioxide Treatment on Microbial Growth and Qualities of Chicken Breast

  • Ko, Jong-Kwan;Ma, Yu-Hyun;Song, Kyung-Bin
    • Preventive Nutrition and Food Science
    • /
    • v.10 no.2
    • /
    • pp.122-129
    • /
    • 2005
  • Chlorine dioxide $(ClO_2)$ treatment was evaluated for microbial growth inhibition and its effects on the quality of vacuum-packaged chicken breasts. Chicken breast samples were treated with 3, 50, and 100 ppm of $ClO_2$ solution, respectively. After $ClO_2$ treatment, chicken breast samples were individually vacuum-packaged and stored at $4^{\circ}C$, a typical storage temperature for meat and meat product, for 7 days. The vacuum-packaged chicken breasts treated with $ClO_2$ had significantly lower total bacteria, yeast and mold, total coliform, and Salmonella spp. were significantly reduced by $ClO_2$ treatment. $D_{10}-values$ of total bacteria count, yeast and mold, total coliform, and Salmonella spp. in vacuum-packaged chicken breasts was 93, 83, 85, and 50 ppm, respectively. The pH of vacuum-packaged chicken breasts decreased with increasing $ClO_2$ concentration. Thiobarbituric acid reacted substance (TBARS) values of vacuum-packaged chicken breasts increased during storage, regardless of $ClO_2$ concentration. $ClO_2$ treatment caused negligible changes in Hunter L, a, and b values in the vacuum-packaged chicken breasts. Sensory evaluation of the vacuum-packaged chicken breasts showed that there were no significant changes among the samples treated with various $ClO_2$ concentration. These results indicate that $ClO_2$ treatment could be useful in improving the microbial safety and quality of meat products.

A Study on the Reliability Evaluation System for O-ring of Semiconductor Equipments (반도체장비용 오링의 종합 신뢰성 평가기술에 관한 연구)

  • 김동수;김광영;최병오;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.613-617
    • /
    • 2001
  • The test items like as endurance, air leakage and oil endurance test is requested for reliability evaluation about O-ring which is a kind of core machinery accessories of semi-conduct manufacturing equipment. For verification of these, we design and manufactured a test system for endurance, air leakage and oil endurance of O-ring for semi-conduct manufacturing equipment, and also performed the test for two kinds of O-ring, as it were Viton and Kalretz. The characteristics of this test equipment consist in realization of the test conditions of semi-conduct manufacturing equipment and satisfying the test method. The test conditions are cut gas, vacuum grade, temperature and revolution numbers in the endurance test system, vacuum grade and temperature in the air leakage test system, temperature and time in the oil endurance test system. The separating test results for wearing which is an oil endurance test item, the wearing index of domestic produced Viton O-ring is higher than foreign product by 2%, wearing rate of Kalretz O-ring better than Viton O-ring by 17%, and particles existed in various place. The test result of air leakage which is measured through the RGA sensor used Helium, the vacuum grade was $10^-3$Torr. And the test result of oil endurance, the volume change rate was 7~15%. Hereafter, we intend to analysis the reliability test evaluation and to utilize for domestic manufacturing companies by establishing data base and developing reliability softwares.

  • PDF

Experimental Approach to Equalizing the Orifice Method with the Throughput One for the Measurement of TMP Pumping Speed

  • Lim, J.Y.;Kang, S.B.;Shin, J.H.;Koh, D.Y.;Cheung, W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.18-18
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. With UHV gauges of uncertainties less than 15% and a calculated conductance of the orifice, about 35% of pumping speed uncertainties are experimentally derived in the pressure range of less than $10^{-6}$ mbar. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced an SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-3}$ mbar-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to less than $10^{-6}$ mbar with an uncertainty of 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.

  • PDF

Storage Stability of Cured Cooked Boneless Chicken Drumette under Vacuum and Its Acceptability as Raw Material for Chuncheon Dakgalbi (춘천닭갈비 원료로서 염지 육계 어깨살의 저장특성)

  • Utama, Dicky Tri;Jeong, Hae Seong;Kim, Juntae;Lee, Sung Ki
    • ANNALS OF ANIMAL RESOURCE SCIENCES
    • /
    • v.29 no.4
    • /
    • pp.183-190
    • /
    • 2018
  • This study was conducted to evaluate the acceptability of cured cooked boneless chicken drumettes as a raw material for Chuncheon Dakgalbi and to observe its effect on pH, lipid oxidation, volatile basic nitrogen (VBN) content and total viable count (TVC) during refrigerated storage under vacuum. Boneless chicken drumettes were dry cured with a mixed curing agent (0.20% w/w) consisting of sodium chloride (93.1%), sodium nitrite (5.9%) and sodium bicarbonate (1.0%) for 24 h at $2{\pm}2^{\circ}C$. Cured samples were cooked using an oven at $150^{\circ}C$ for 20 min and stored at $5.5{\pm}0.5^{\circ}C$ for 60 days under vacuum. Non-cured cooked sample was used as a control. Sensory evaluation was performed on day 2 of storage using 22 untrained panelists and samples were mixed with Dakgalbi sauce and reheated using a microwave for 2 min. There were no significant differences between control and treatment group on appearance, flavor, texture, juiciness and overall acceptability. Cured cooked boneless chicken drumettes had significantly (p<0.05) higher pH, lower lipid oxidation, VBN and TVC consistently during storage in comparison with control. These results suggest that dry curing could be applied to boneless chicken drumettes as raw material for Chuncheon Dakgalbi and could extend its shelf life during refrigerated storage under vacuum.