• Title/Summary/Keyword: VSI

Search Result 306, Processing Time 0.022 seconds

DC-Link Voltage Ripple Analysis of Minimum Loss Discontinuous PWM Strategy in Two-Level Three-Phase Voltage Source Inverters (최소 손실 불연속 변조 기법에 따른 2레벨 3상 전압원 인버터의 직류단 전압 맥동 분석)

  • Lee, Junhyuk;Park, Jung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.120-126
    • /
    • 2021
  • DC-link capacitors are one of the main components in two-level three-phase voltage source inverters (VSIs); they provide the pulsating input current and stabilize the vacillating DC-link voltage. Ideally, the larger the capacitance of DC-link capacitors, the better the DC-link voltage stabilizes. However, high capacitance increases the cost and decreases the power density of VSI systems. Therefore, the capacitance should be chosen carefully on the basis of the DC-link voltage ripple requirement. However, the DC-link voltage ripple is dependent on the pulse-width modulation (PWM) strategy. This study especially presents a DC-link voltage ripple analysis when the minimum loss discontinuous PWM strategy is applied. Furthermore, an equation for the selection of the minimum capacitance of DC-link capacitors is proposed. Experimental results with R-L loads are also provided to verify the effectiveness of the presented analysis.

Contribution of Microbleeds on Microvascular Magnetic Resonance Imaging Signal

  • Chang Hyun Yoo;Junghwan Goh;Geon-Ho Jahng
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.88-100
    • /
    • 2022
  • Purpose: Cerebral microbleeds are more susceptible than surrounding tissues and have been associated with a variety of neurological and neurodegenerative disorders that are indicative of an underlying vascular pathology. We investigated relaxivity changes and microvascular indices in the presence of microbleeds in an imaging voxel by evaluating those before and after contrast agent injection. Methods: Monte Carlo simulations were run with a variety of conditions, including different magnetic field strengths (B0), different echo times, and different contrast agents. ΔR2* and ΔR2 and microvascular indices were calculated with varying microvascular vessel sizes and microbleed loads. Results: As B0 and the concentration of microbleeds increased, 𝜟R2* and 𝜟R2 increased. 𝜟R2* increased, but 𝜟R2 decreased slightly as the vessel radius increased. When the vessel radius was increased, the vessel size index (VSI) and mean vessel diameter (mVD) increased, and all other microvascular indices except mean vessel density (Q) increased when the concentration of microbleeds was increased. Conclusions: Because patients with neurodegenerative diseases often have microbleeds in their brains and VSI and mVD increase with increasing microbleeds, microbleeds can be altered microvascular signals in a voxel in the brain of a neurodegenerative disease at 3T magnetic resonance imaging.

Comparison of Educational Effectiveness Between Instructor-Centered Learning and Video Self-Instruction about Automatic External Defibrillator for High School Girls (여고생의 자동제세동기에 대한 강사중심학습과 영상자가학습과의 교육효과 비교)

  • Park, Sang-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1732-1739
    • /
    • 2011
  • This study aims to make a comparison of educational effectiveness between instructor-centered learning and video self-instruction(VSI) about automatic external defibrillator(AED) for high school girls in order to help select an effective teaching method concerning AED. A total of 59 high school girls (29 for the experimental group, 30 for the control group) in J Province participated in this study from July 7 to 14, 2010. The analysis was carried out by using an SPSS WIN 12.0 Version program. After the AED instruction, the knowledge increased more in the experimental group (1.72) than that in the control group (1.60); self-confidence increased more in the experimental group (1.58) than that in the control group (1.46); and accuracy of technical performance increased more in the control group (5.46) than that in the experimental group (4.20). The experimental group (5.68) was more satisfied with AED instruction than the control group (4.95). Since video self-instruction proved to be more educationally effective than instructor-centered learning in most areas, it is necessary to apply video self-instruction to AED instruction in the future. However, further researches are necessary to see if video self-instruction is effective.

Markov Chain Method for Monitoring Several Correlated Quality Characteristics with Variable Sampling Intervals

  • Chang, Duk-Joon
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.3
    • /
    • pp.39-50
    • /
    • 1997
  • Markov chain method to evaluate the properties of control charts with variable sampling intervals(VSI0 for simultaneously monitoring several correlated quality characteristics under multivariate normal process are investigated. For comparing the efficiencies and properties of multivariate control charts, we consider multivariate Shewhart, CUSUM and EWMA charts in terms of average time to signal(ATS) and average number of samples to signal(ANSS). We obtained stabilized numerical results with Markov chain method when the number of transient state is greater than 100.

  • PDF

Properties of variable sampling interval control charts

  • Chang, Duk-Joon;Heo, Sun-Yeong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.4
    • /
    • pp.819-829
    • /
    • 2010
  • Properties of multivariate variable sampling interval (VSI) Shewhart and CUSUM charts for monitoring mean vector of related quality variables are investigated. To evaluate average time to signal (ATS) and average number of switches (ANSW) of the proposed charts, Markov chain approaches and simulations are applied. Performances of the proposed charts are also investigated both when the process is in-control and when it is out-of-control.

Improved PWM for reducing torque ripple in PMSM with B4 inverter (인버터 폴트 (B4) 환경 하에 토크리플 절감을 위한 개선된 변조방식)

  • Park Jin-Sik;Jung Sin-Myung;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.292-294
    • /
    • 2006
  • This paper presents a study on the use of improved space-vector modulation of VSI employing only four switches, four body diodes. Different switching sequence strategy for vector control for inverter fault mode are described. The influence of different switching patterns at same modulation index and improved PWM method is proposed. The proposed PWM is compared with conventional PWM. Simulation and experimental results are presented.

  • PDF

두 개의 이상원인을 고려한 VSSI $\bar{X}$ 관리도의 통계적 특성

  • 이호중;임태진
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2004.04a
    • /
    • pp.64-69
    • /
    • 2004
  • This research investigates statistical characteristics of variable sampling size & interval(VSSI) X charts under two assignable causes. Algorithms for calculating the average run length(ARL) and average time to signal(ATS) of the VSSI X chart are proposed by employing Markov chain method. Extensive sensitivity analysis shows that the VSSI. X chart is superior to the VSS or VSI X chart as well as to the Shewhart X chart in statistical sense, even under two assignable causes.

  • PDF

Steady-State Torque Pulsations in Current Source Inverter Fed Induction Motor Drives (전류원 인버터로 구동되는 유도전동기의 맥동토오)

  • 신휘범;윤명중
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.4
    • /
    • pp.197-204
    • /
    • 1988
  • A simple method that estimates the torque fluctuations in induction motor driven by CSI under steady state condition is presented and that uses the phasor diagram from the modified singlephase equivalent circuit. This method is also applied to evaluate the PWM and programmed do link modulation techniques for reducing the torque pulsations. The simplified calculations are compared with the exact digital solutions from machine D-Q equation. It is noted that the torque pulsations in induction motor driven by CSI are dependent upon the load condition unlike VSI.

  • PDF

Failure Mode of 3 Phase VSI by using Average Method of Power Loss (전력 손실 평균화 기법에 의한 3상 전압형 인버터의 소손 모드에 관한 연구)

  • Cho, Su-Eog
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.199-201
    • /
    • 2007
  • 본 논문에서는 저가의 3상 전압형 인버터를 개발하기 위하여, 시스템에 최적화된 전력 변환 장치로 설계하고 이 때 산업 사회에서 요구하는 수명을 만족하기위해 실시간으로 전력 손실을 감시하여 전력 반도체의 수명을 보장하고, 소손 시 분석을 용이하게 하기위하여 소손 모드를 패턴 화 하였다. 전력반도체 열 손실의 이상 유무를 평균 전류 혹은 평균 손실을 이용하여 계산된 온도 상승 기울기와 방열판에서 실측된 온도 상승 기울기와 비교하여 일정 범위 내에 존재함을 확인함으로서 그 가능성을 실험을 통하여 확인하였다.

  • PDF

Influence on the Ground Reaction Force Parameters According to Wearing Positions of Backpacks During Stair Ascending and Descending (계단 오르기와 내리기 시 가방착용 위치가 지면반력 파라미터에 미치는 영향)

  • Hyun, Seung-Hyun;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.85-94
    • /
    • 2015
  • Purpose : The purpose of this study was to investigate the influence on the ground reaction force parameters according to wearing positions of backpack for during stair ascending and descending. Methods : Participants selected as subject were consisted of young female(n=10) and performed stairs walks(ascending and descending) with 2 types of wearing position(front of trunk[FT], rear of trunk[RT]). Passive(Fz 1) and active(Fz 2) forces of the vertical GRF were determined from time function and frequency domain. Also shear forces(Fx, Fy 1, Fy 2), dynamic postural stability index(MLSI, APSI, VSI, DPSI), loading rate and center of pressure (${\Delta}COPx$, ${\Delta}COPy$, COP area) were calculated from time function and frequency domain. Results : Fx, Fy 1, Fy 2, and Fz 1 in GRF didn't show significant differences statistically according to the wearing positions of backpack(p>.05), but stair descending showed higher forces than that of stair ascending. Particularly, Fz 2 of stair ascending showed higher forces than that of stair descending(p<.001), RT types showed higher than that of FT types(p<.05). MLSI, APSI, VSI, and DPSI of stair descending showed the increased stability index than that of stair ascending(p<.05), MLSI of RT types showed the decreased stability index than that of FT types(p<.05). Loading rate didn't show significant differences statistically according to the wearing positions of backpack(p>.05), but stair descending showed higher loading rate than that of stair ascending(p<.001). Also, ${\Delta}COPx$ in stair descending showed the increased movement than that of stair ascending(p<.05). Conclusions : A backpack of 10 kg(10 kg(ratio of body weights $17.61{\pm}1.17%$) showed significantly change GRF parameters according to wearing positions during stair ascending and descending. If possible, we suggest that the dynamic stability, in case of stairs walking with a smaller weights can be further improved.