• Title/Summary/Keyword: VSC

Search Result 276, Processing Time 0.035 seconds

PSCAD/EMTDC Simulation for Modular Multilevel Converter System (Modular Multilevel Converter 시스템을 위한 PSCAD/EMTDC 시뮬레이션)

  • Son, G.T.;Lee, H.J.;Beak, S.T.;Lee, U.H.;Chung, Y.H.;Hur, K.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1214-1215
    • /
    • 2011
  • 현재 HVDC 및 FACTS와 같은 전력전자소자 기반 전력기기의 최신 개발은 능동형 스위치소자의 발전 및 설치 환경의 변화로 인하여 VSC Topology로 이동되고 있다. 하지만 VSC Toplolgy의 스위칭 손실등의 문제로 대용량 전력기기의 경우 MMC(Modular Multilevel Converter) 적용이 가속화되고 있다. 이에 본 논문에서는 MMC Topology의 특징, 구동 원리, 시뮬레이션 과정을 소개한다. Modulation 및 Quantization 그리고 Sorting Algorithm을 통해 7-level, 151-level 삼상 MMC Topology을 시뮬레이션을 수행하였다.

  • PDF

Characteristic analysis of LCC and VSC HVDC system in Jeju power system using RTDS (RTDS를 이용한 제주도 전력계통에서의 전압형과 전류형 직류송전 시스템 특성분석)

  • Ju, Chang-Hyeon;Kim, Jin-Geun;Dinh, Minh-Chau;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.828-829
    • /
    • 2011
  • This paper performs a comparison analysis of two types of HVDC system in Jeju power system. A traditional HVDC transmission system had been composed of line commutated converter based on thyristors and the development of semiconductors enables to apply voltage source converter using IGBTs. The detailed parameters of Jeju power system were considered to make a similar condition with real system in real time digital simulator. Two types of HVDC transmission system were modeled and simulated to compare their characteristics in Jeju power system. The simulation results demonstrate that the VSC-HVDC system has more stable performance due to the fast response speed than LCC-HVDC when the transmission capacity was fluctuated.

  • PDF

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.

Analysis. Design and Control of Two-Level Voltage Source Converters for HVDC Systems

  • Mohan, D. Madhan;Singh, Bhim;Panigrahi, B.K.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.248-258
    • /
    • 2008
  • The Voltage Source Converter (VSC) is replacing the conventional line commutated current source converters in High Voltage DC (HVDC) transmission systems. The control of a two-level voltage source converter and its design dealt with HVDC systems and various factors such as reactive power, power factor, and harmonics distortion are discussed in detail. Simulation results are given for the two-level converter and designed control is used for bidirectional power flow. The harmonics minimization is taken by extending the 6-pulse VSC to multipulse voltage source converters. The control is also tested and simulated for a 12-pulse voltage source converter to minimize the harmonic distortion in AC currents.

Variable Structure Control using Inertial Coordinate-Operator Feedback (Inertial Coordinate-Operator Feedback을 이용한 가변구조제어)

  • You, Wan-Sik;Hur, Young-Jae;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.465-467
    • /
    • 1994
  • A VSC with Inertial COFB(Coordinate-Operator Feedback) is presented for chattering alleviation. Athought the conventional sliding mode controller has good properties of robustness for disturbances or parameter variations, fast response, and easy implementation, there exists an inevitable chattering problem which deteriorates the control performance of system. VSC using Inertial COFB has properties of bounded feedback gain, reduced chattering, and robustness for disturbances or parameter variations. The validity of the proposed method is demonstrated through computer simulation for a position control of BLDCM.

  • PDF

A Novel Solid State Controller for Parallel Operated Isolated Asynchronous Generators in Pico Hydro Systems

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.358-365
    • /
    • 2007
  • This paper deals with a novel solid state controller (NSSC) for parallel operated isolated asynchronous generators (IAG) feeding 3-phase 4-wire loads in constant power applications, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of asynchronous generators. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 4-leg voltage source converter (CC-VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The complete system is modeled in MATLAB along with simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of isolated generating system consisting of NSSC and parallel operated asynchronous generators driven by uncontrolled pico hydro turbines and feeding 3-phase 4-wire loads.

Stability Analysis of Jeiu Power System added with HVDC (HVDC 추가도입에 대한 제주도 계통의 정태 안정도 분석)

  • Shin, Seong-Su;Kim, Do-Hyung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.491-493
    • /
    • 2008
  • This paper presents results of comparing CSC HVDC with VSC HVDC on the stability in case of connecting Haenam to Jeju electrical power system, the steady-state stability in the case of Jeju electrical power system with CSC HYDC or VSC HVDC, is validated through PV curve, QV curve of Jeju electrical power system. And in the case of CSC HVDC, it is considered that synchronous condenser is connected or not. The results are compared each other. PSS/E simulation tool is used for the steady-state stability analysis.

  • PDF

Battery Energy Storage System Based Controller for a Wind Turbine Driven Isolated Asynchronous Generator

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.81-90
    • /
    • 2008
  • This paper presents an investigation of a voltage and frequency controller for an isolated asynchronous generator (IAG) driven. by a wind turbine and supplying 3-phase 4-wire loads to the isolated areas where a grid is not accessible. The control strategy is based on the indirect current control of the VSC (voltage source converter) using the frequency PI controller. The proposed controller consists of three single-phase IGBT (Insulated Gate Bipolar Junction Transistor) based VSC, which are connected to each phase of the IAG through three single phase transformers and a battery at their DC link. The controller has the capability of controlling reactive and active powers to regulate the magnitude and frequency of the generated voltage, harmonic elimination, load balancing and neutral current compensation. The proposed isolated system is modeled and simulated in MATLAB using Simulink and PSB (Power System Block-set) toolboxes to verify the performance of the controller.

A Test System of Valve and Poles for Large Scale Inverter using Resonant Circuit (공진회로를 이용한 대용량 인버터 구성용 밸브 및 폴 시험설비에 관한 연구)

  • Han, Young-Seong;Chung, Chung-Choo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.971-976
    • /
    • 2011
  • This paper proposes a test system for a valve and poles building blocks used for large scale inverters such as STATCOM, SSSC, UPFC and VSC HVDC. Power semiconductors in the valve are normally connected in series to withstand switching voltage much larger than the voltage rating of a single power semiconductor. Therefore, there is a need to verify if the dynamic voltage sharing during switching in a valve is satisfactory. In this paper, we propose a test system that provides the necessary test condition: voltage and current in the valve using resonant circuits. A test scheme for a single phase inverter consisting two poles is also proposed. The performance of the inverter pole has to be verified at the factory test, before the system is installed at the site to secure the reliability of the system. The proposed scheme makes it possible to confirm if the pole can withstand voltage and current switching condition and handle loss.

Grid-Connected Off-Shore Wind Power System Using 3-Level ANPC VSC (Active Neutral-Point-Clamped Voltage Source Converter) (Active NPC를 적용한 계통연계형 해상 풍력 발전용 전력변환 시스템)

  • Hong, Seok-Jin;Shin, Soo-Cheol;Lee, Hee-Jun;Choi, Chi-Hwan;Won, Chung-Yuen;Kim, Hack-Seong
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.249-250
    • /
    • 2012
  • 해상 풍력 발전은 가장 유망한 재생 에너지원의 하나이며, 육상 풍력 발전보다 풍력이 강력하고 일정하여 장시간 고출력 발생이 가능하다. 또한 소음, 공간적 한계, 경관훼손 등 기존 육상 풍력 발전의 단점을 보완하고 초대형 단지조성이 가능한 장점이 있다. 초대형 해상풍력단지에는 일반적으로 MW급의 해상풍력발전기가 사용된다. 본 논문에서는 MW급의 해상 풍력발전기에 ANPC(Active Neutral-Point-Clamped) Multi-Level VSC(Voltage Source Converter)를 적용하여 Back-to-Back으로 구성한 시스템을 제안하고 계통연계형 풍력 발전 시스템을 모의한 시뮬레이션을 통하여 제안된 시스템의 성능을 검증한다.

  • PDF