Optimization of Wind Turbine Pitch Controller by Neural Network Model Based on Latin Hypercube (라틴 하이퍼큐브 기반 신경망모델을 적용한 풍력발전기 피치제어기 최적화)

  • Lee, Kwangk-Ki;Han, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.9
    • /
    • pp.1065-1071
    • /
    • 2012
  • Wind energy is becoming one of the most preferable alternatives to conventional sources of electric power that rely on fossil fuels. For stable electric power generation, constant rotating speed control of a wind turbine is performed through pitch control and stall control of the turbine blades. Recently, variable pitch control has been implemented in modern wind turbines to harvest more energy at variable wind speeds that are even lower than the rated one. Although wind turbine pitch controllers are currently optimized using a step response via the Ziegler-Nichols auto-tuning process, this approach does not satisfy the requirements of variable pitch control. In this study, the variable pitch controller was optimized by a genetic algorithm using a neural network model that was constructed by the Latin Hypercube sampling method to improve the Ziegler-Nichols auto-tuning process. The optimized solution shows that the root mean square error, rise time, and settle time are respectively improved by more than 7.64%, 15.8%, and 15.3% compared with the corresponding initial solutions obtained by the Ziegler-Nichols auto-tuning process.

Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode (자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향)

  • Jeong, Woon-Chan;Joo, Young-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

Resistance of Vibrio parahaemolyticus Against the Environmental Factors (Vibrio parahaemolyticus의 환경인자(環境因子)에 대(對)한 저항성(抵抗性))

  • Kim, Sang-Chual;Kim, Doo-Hie;Park, Soon-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.183-194
    • /
    • 1988
  • This study was carried out to investigate for resistance of V. parahaemolyticus that isolated from patients of food poisoning and fish and shellfish, captured in east coast of Kyungpook province of Korea from 1985 to 1986. VP ATCC 17802 and NAG V. ATCC 6538 were used as control. In fish, shellfish and seaweed, the more temperature increased, the shorter survival time was. In case of sea-water, the more temperature rose up, the longer survival time was, particularly in $37^{\circ}C$ and $25^{\circ}C$, the strains had survived after 6 months. And in tapwater, it was sterilized in 150 mins. and survived for 11.5 days on maximum in ground water. In kimchi, at room temperature, germicidal time was shorter more than 6 times compared with that which had been kept in refrigerator. It survived for 57.1 days in milk, 49.2 mins. in yougurt. Strains had been surviving in frozen condition at $-70^{\circ}C$ even after 6 months, present study time. In resistance test in water bath at several degrees of temperature, all the strains were sterilized in 20 mins. with $60^{\circ}C$. In resistance test to driness, number of surviving strains dropped rapidly in 10-11%) water contents. In UV $2538{\AA}$, strains were sterilized in 20 mins. In resistance test to alcohol, strains had survived for 0.1-4 mins. in fermentative wine of below than 25% and distilled wine of over than 25% in alcohol concentration. The bactericidal concentration of disinfectant was 1% in phenol and 3% in cresol. In 0.1M acetic acid and 0.1M lactic acid, number of surviving colonies decreased rapidly but not in citric acid. The more NaCl concentration rose up, the lower decreasing rate of number of surviving colonies was. The strains had showed sensitive response to vancomycin, chloramphenicol, gentamicin, and resisted to carbenicillin, ampicillin and kanamycin. When one day culture strain was cultured till 25th day, resistant strains to tetracycline and cephalothin were changed to sensitive.

  • PDF

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Discrimination of Postradiotherapy Lung Fibrosis from Recurrence by Gallium-67 Scan in Lung Cancer (갈륨 스캔을 이용한 폐암의 치료 후 섬유성 변성과 재발의 감별)

  • Ryu, Sam-Uel;Lee, Jae-Tae
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.81-85
    • /
    • 1991
  • The differentiation between post-radiotherapy lung fibrosis and tumor recurrence is often a dilemma to physicians. Twenty two patients with lung cancer who had received 45~60 Gy to the chest were chosen to study the possible role of gallium-67 scan. Seventeen squamous cell carcinomas were treated with only radiotherapy, 3 small cell carcinomas with combination chemotherapy, 2 adenocarcinomas with lobectomy. A total of 8 patients with pneumonitis with or without fibrosis and recurrence showed uptake of gallium at the site of inflammation. Of the 12 recurrences and residual diseases after radiotherapy, positive gallium uptake was present in 11 cases (92%). Of the 10 recurrence-free cases, all the 5 patients with pneumonitis revealed gallium accumulation. However, 4 of the 5 patients (80%) with recurrence-free fibrosis have not accumulated gallium in the fibrotic areas. Fibroses in S patients were developed after 8 months of completion of radiotherapy. These facts suggest that gallium-67 scan after 1 year post-treatment may aid for the discrimination of fibrosis from tumor recurrence unless pneumonitis is present.

  • PDF

Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector (디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구)

  • Kim, Byung-Ki;Kim, Sang-Keun;Cha, Seon-Hwa;Choi, Jun-Gu;Lee, Jun;Kim, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Sun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

반도체 검출기의 절연 최적화를 위한 다층 절연막 평가

  • Park, Jeong-Eun;Myeong, Ju-Yeon;Kim, Dae-Guk;Kim, Jin-Seon;Sin, Jeong-Uk;Gang, Sang-Sik;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.372-372
    • /
    • 2014
  • 반도체 검출기는 입사되는 X선 에너지에 의하여 이온화되어 발생하는 전자 전공쌍을 수집함으로 방사선 정보를 확인하는 선량계로써 많은 연구와 활용이 이루어지고 있다. 하지만, X선 에너지에 의하여 반도체 검출기에서 발생하는 전기적 신호량이 높지 않기 때문에 누설 전류의 저감이 필수적이다. 누설 전류를 저감시키기 위한 방안으로 반도체 층과 전극 층의 Schottky Contact 구조의 설계, Insulating Layer의 사용, 높은 비저항의 반도체 물질 연구 등이 이루어지고 있다. 하지만, 기존에 누설 전류 저감을 위하여 Insulating Layer를 전극층과 반도체 층 사이에 형성하는 연구에 있어서 Insulating Layer와 반도체 층의 계면 사이에서 발생하는 Charge Trapping으로 인하여 생성되는 신호의 Reproducibility 저하, 동영상 적용의 제한 등의 문제점을 겪어왔다. 이에 본 논문에서는 누설 전류를 저감시킴과 동시에 Charge Trapping의 최소화를 이루기 위하여 Insulating Layer의 두께 최적화 연구를 수행하였다. 본 연구에서 사용한 Insulating Layer는 검출기 표면에 입사하는 X선 정보 손실을 최소화 시키는 동시에 누설 전류와 Charge Trapping을 최소화 시키는 방법으로써 CVD방법으로 검출기 표면에 균일하게 Insulating Layer를 코팅하였다. Insulating 물질은 Parylene을 사용하였으며, 그 중 온도, 습도 등 외부환경에 영향을 적게 받는 type C를 사용하였다. 증착에 사용한 장비의 진공도는 Torr로 설정하여 증착되는 Parylene의 두께가 약 $0.3{\mu}m$가 되게 하였으며, 실험에는 반도체 물질 PbO를 사용하였다. Parylene의 절연 특성은 Dark Current와 Sensitivity를 측정한 SNR을 이용하여 Parylene코팅이 되지 않은 동일 반도체 검출기와의 신호를 비교하였으며 또한 Parylene를 다층 제작한 검출기의 수집 신호량을 비교하였다. 제작한 검출기의 X선 조사 시의 수집 전하량 측정 결과, 100 kVp, 100mA, 0.03s의 X선 조건에서 $1V/{\mu}m$의 기준 시, Parylene를 코팅하지 않은 PbO 검출기의 Dark current는 0.0501 nA/cm2, Sensitivity는 0.6422 nC/mR-cm2, SNR은 12.184이었으며, Parylene단층의 두께인 $0.3{\mu}m$로 증착된 시편의 Dark current는 0.04097 nA/cm2, Sensitivity는 0.53732 nC/mR-cm2으로 Dark current가 감소되고 sensitivity도 감소하였지만 SNR은 13.1150으로 높아진 것을 확인할 수 있었다. Perylene이 $0.6{\mu}m$로 증착된 시편의 경우, Dark Current는 0.04064 nA/cm2, Sensitivity는 0.31473 nC/mR-cm2, SNR은 7.7443으로써 Insulating Layer가 없는 시편보다 SNR이 약 40% 낮아진 것을 확인할 수 있었다. Parylene이 $0.9{\mu}m$로 증착된 시편의 경우 Dark current는 0.0378 nA/cm2, Sensitivity 0.0461 nC/mR-cm2로 Insulating Layer가 없는 시편에 비해 SNR은 약 1/12배 감소한 1.2196이었고, Parylene이 $1.2{\mu}m$로 증착된 시편의 SNR은 1.1252로서 더 감소하였다. 따라서 Parylene을 다층 코팅한 검출기일수록 절연 효과의 영향이 커짐으로써 SNR 비교 시 수집되는 신호량이 줄어드는 것을 확인하였다. 반도체 검출기의 누설 전류를 저감시킴과 동시에 신호 수집율에 영향을 최소화시키기 위하여 Insulating Layer의 두께를 적절하게 설정하여 적용하면 Insulating Layer가 없는 검출기에 비해 누설전류를 최소한으로 줄일 수 있고 신호 검출효율이 감소하는 것을 방지할 수 있을 것이라 사료된다.

  • PDF

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries (복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구)

  • Jang, Ji-Sung;Choi, Weon-Keun;Jung, Jae-Yon;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

Performance Evaluation of Aprons according to Lead Equivalent and Form Types (방사선 방어용 앞치마의 납당량, 형태에 따른 성능 평가)

  • Kim, Ki-Won;Choi, Sung-Hyun;Kim, Ki-Yeol;Lee, Ik-Pyo;Hwang, Sun-Gwang;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.219-225
    • /
    • 2016
  • The apron is one of the essential protectors to reduce the exposure dose of radiological technologists. This study is to provide a guideline for purchasing the aprons with excellent performance and to help reducing the exposure dose by measuring the shielding ration and uniformity of aprons according to lead equivalent and form types. The shielding ratio of aprons were measured by using radiation generator and dosimeter. Exposure conditions were 81 kVp, 25 mAs, source to image receptor distance (SID) 100 cm and field of view (FOV) $17^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$. Exposure areas for front type and around type aprons were divided into 9 areas and for 2 pieces type aprons were divided into 3 areas of top and 4 areas of skirt. The uniformity of aprons were measured by using fluoroscopy and Image J. The 4 regions of interest (ROI) were set into acquired images and measured uniformity by measuring the standard deviation of pixel intensity in ROIs. In continuous shielding ration measurement of aprons according to exposure area, there was not statistical significance (P>0.05). In ANOVA test of aprons, there was statistical significance (P<0.01). In the results of sheilding ratio, although the aprons had equal lead equivalent, there were difference in shielding ratio from 83.59% to 98.15%. In the results of uniformity, the front type aprons with equal lead equivalent indicated the similar uniformity. However, the around type and 2 pieces type apron with equal lead equivalent indicated the different uniformity each other, from 1.8 to 22.2. If the performance evaluation in this study were conducted regularly before and after purchase the aprons, the exposure does to patients and radiological technologists could be reduced.