• Title/Summary/Keyword: VP2

Search Result 639, Processing Time 0.034 seconds

중국 황도화(黃島話)의 'NP1+VP+기(起)+NP2'구문에 관한 초보적 고찰

  • Chae, Chun-Ok
    • 중국학논총
    • /
    • no.63
    • /
    • pp.65-90
    • /
    • 2019
  • In Huangdao Dialect, the "NP1+VP+起+NP2" sentence structure can not only be used with monosyllabic and bisyllabic adjectives and active adjectives, but also with passive adjectives. The usage of the VP is broader in Huangdao Dialect than in Qingdao dialect in case it is a verb phrase. The negative of "NP1+VP+起+NP2" sentence structure uses "不" or "沒有." If common comparative element can be found between NP1 and NP2, the negative particles are used at the beginning of the sentence in general to generate topic sentences. NP1 is often a common noun, modifying phrase, and quantifying phrase, while it can also be a verb-object phrase or modifying phrase. Huangdao Dialect may exhibit specific quantifying phrases that express comparative differences. The inquisitive style of "NP1+VP+起+NP2" sentence structure include appending a question mark at the end of the sentence, combining the positive and negative forms of the adjective, and appending "'是沒" or "是不是" in the front of the adjective.

The Activity of Standard and Fast SCR over V-based Catalysts Supported on Various TiO2 (다양한 TiO2에 담지된 바나디아 촉매의 표준 및 빠른 SCR 활성)

  • Ji Eun Jeong;Yeon Jeong Jo;Inyoung Lee;Jeongkeun Lee;Chang-Yong Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.584-589
    • /
    • 2023
  • The physicochemical properties of VOx/TiO2 catalysts with different TiO2 supports were analyzed, and SCR reactions were performed. VOx/TiO2 catalysts were prepared by impregnation using anatase TiO2, which was manufactured by Sigma Aldrich and prepared from TiOCl2 and titanium isopropoxide (TTIP) as a precursor. They are denoted as VS, VC, and VP. The specific surface area of the VS was 1/10 or less of that of the VC and VP, and the dispersibility of vanadium oxide was relatively low. As a result of XPS analysis, the ratio of adsorbed oxygen was higher in VS and VP with Ti3+ than in VC. In VC and VP, vanadium mainly existed in V4+ and V3+ states in relation to the dispersibility of vanadium oxide. The amount of adsorbed oxygen contributed more to NH3-SCR activity than vanadium oxide dispersibility below 250 ℃, while vanadium oxide dispersibility contributed more to activity beyond 300 ℃. The fast SCR activity in all three samples was the highest at NO2/NOx = 0.5, followed by VS < VC < VP samples. It was determined that the dispersibility of vanadium oxide had a significant effect on fast NH3-SCR activity.

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

Silent Verbs in Northern Mandarin: A Silence Neither Gaps Nor Emptiness Can Fill

  • Kim, Ji-Yung
    • Language and Information
    • /
    • v.11 no.2
    • /
    • pp.87-103
    • /
    • 2007
  • This paper reanalyzes examples with missing verbs. Northern Mandarin rejects argument nominal phrases after a silent verb, as well as silent verbs inside islands. These restrictions suggest a grammatical process which silences verbs. I propose that these restrictions are the result of VP-topicalization followed by ellipsis. This analysis accounts for the island sensitivity of these constructions: since VP-topicalization feeds ellipsis, constructions with elided VPs are not derivable from configurations where movement is impossible. Also, to avoid topicalization along with the VP, the argument must move out of VP; the subsequent topicalization of the VP containing the argument's trace would then give rise to a configuration where that trace c-commands the moved-out DP. Adjuncts do not pose a problem because they are located outside of that smallest VP-shell. The data presented here are accommodated by neither of Tang's (2001) proposals for silent verbs (gapping and empty verbs). Instead, they provide support for a third source for silent verbs, VP-ellipsis via topicalization.

  • PDF

Surface Micelle Formation of Polystyrene-b-Poly(2-vinyl pyridine) Diblock Copolymer at Air-Water Interface

  • Park, Myunghoon;Bonghoon Chung;Byungok Chun;Taihyun Chang
    • Macromolecular Research
    • /
    • v.12 no.1
    • /
    • pp.127-133
    • /
    • 2004
  • We have studied the surface micelle formation of polystyrene-b-poly(2-vinyl pyridine) (PS-b-P2VP) at the air-water interface. A series of four PS-b-P2VPs were synthesized by anionic polymerization, keeping the PS block length constant (28 kg/㏖) and varying the P2VP block length (1, 11, 28, or 59 kg/㏖). The surface pressure-area ($\pi$-A) isotherms were measured and the surface morphology was studied by atomic force microscopy (AFM) after Langmuir-Blodgett film deposition onto silicon wafers. At low surface pressure, the hydrophobic PS blocks aggregate to form pancake-like micelle cores and the hydrophilic P2VP block chains spread on the water surface to form a corona-like monolayer. The surface area occupied by a block copolymer is proportional to the molecular weight of the P2VP block and identical to the surface area occupied by a homo-P2VP. It indicates that the entire surface is covered by the P2VP monolayer and the PS micelle cores lie on the P2VP monolayer. As the surface pressure is increased, the $\pi$-A isotherm shows a transition region where the surface pressure does not change much with the film compression. In this transition region, which displays high compressibility, the P2VP blocks restructure from the monolayer and spread at the air-water interface. After the transition, the Langmuir film becomes much less compressible. In this high-surface-pressure regime, the PS cores cover practically the entire surface area, as observed by AFM and the limiting area of the film. All the diblock copolymers formed circular micelles, except for the block copolymer having a very short P2VP block (1 kg/㏖), which formed large, non-uniform PS aggregates. By mixing with the block copolymer having a longer P2VP block (11 kg/㏖), we observed rod-shaped micelles, which indicates that the morphology of the surfaces micelles can be controlled by adjusting the average composition of block copolymers.

Syntactic Ambiguities and their Resolution in Prosody in Japanese (일본어 유악센트 방언과 무악센트 방언의 통사적 애매성의 해소와 운율적 특징)

  • Choi, Young-Sook
    • Speech Sciences
    • /
    • v.9 no.3
    • /
    • pp.211-221
    • /
    • 2002
  • The prosody can play a crucial role in differentiating ambiguous sentences to correctly reflect their intended syntactic structures. In what way do the speakers in Tokyo and Sendai dialects of Japanese use prosodic elements to differentiate syntactic ambiguities? Acoustic measurement was made of utterances of ambiguous sentences in Japanese to observe prosodic strategies for disambiguation. Materials were sentences of the type ADV-VP1-NP-VP2, ADV-NP1-NP2-VP2, where the ambiguity lies in locative adverbial modification, ADV modifying either VP1 or VP2. For this construction the Japanese create the same ambiguities. After defining the depth of a syntactic boundary, F0 of the phrase before and after the boundary, and duration of the syllable and pause before the boundary were measured. The results show that Tokyo dialects speakers use F0 after syntactic boundary, and Sendai dialects speakers use of the syllable and/or pause before the boundary.

  • PDF

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.

Quality and Shelf-life of Chilled Smoked Pork Belly Depending on Packaging Methods (포장방법에 따른 냉장 훈제삼겹살의 품질과 저장성)

  • Lim, Ji-Hoon;Cheong, Sung-Hee;Lee, Sung-Ki;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.2_3
    • /
    • pp.43-51
    • /
    • 2010
  • The changes in quality and shelf life of smoked pork belly according to packaging methods were investigated during storage at $5{\pm}1^{\circ}C$ up to 12 days. Three packaging treatments including air-containing packaging (AC), vacuum packaging (VP), and packaging incorporated with oxygen scavenger (OS) were applied in this experiment. In all treatments, the initial total aerobic plate count (TPC) was 2.4 log cfu/g which was increased with storage period. The rapidest increase of TPC was observed in the AC samples, followed by OS and VP. The VP samples showed inhibiting effects on the growth of Pseudomonas spp. and coliforms over the storage. The TBA values were increased in the order of AC-OS-VP. The VBN values of the VP and OS samples tended to be increased slower than the AC samples during the storage. According to the sensory evaluations, the point of losing marketability in the raw AC, OS, and VP samples was determined to be the day 8, 10, and 12, respectively. However, the evaluations for the cooked samples showed the AC and OS samples preserved the marketing value until the day 10 and 12, while the VP samples until the day 12 except in the parameter of texture. In conclusion, it was found that the most appropriate packaging method for preserving the quality and extending the shelf life of chilled smoked pork belly is vacuum packaging.

  • PDF

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

Evaluation of Image Quality and dose with the Change of kVp and BMI in the Liver CT (CT 검사 시 관전압과 BMI 변화에 따른 화질 및 피폭평가)

  • Kim, Dong-Hyun;Ko, Sung-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Choi, Seok-Yoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.331-338
    • /
    • 2013
  • CT for follow-up visits because of liver disease, body mass index (BMI) and kVp according to the change of the image quality and radiation dose to evaluate for changes. March 2010 to June 2011 at Pusan P University Hospital, abdominal CT scans a patient BMI (Body Mass Index. Less BMI) index was less than 25 in the treatment of subjects had a 48-person Noise and SNR at 100kVp abdominal image is lager than the 120kVp image. CTDI volume value at by the analysis of the radiation dose is 4.47mGy(100kVp) and 9.01mGy(120kVp). So CTDIvol in 100kVp is smaller than CTDIvol in 120kVp(decrease by 44.1%). And, effective dose is 7.1mSv(100kVp) and 12.51mSv(120kVp). So effective dose in 100kVp is smaller than effective dose in 120kVp(decrease by 43%). Evaluation of image quality is that Unacceptable 0 person, Suboptimal 0 person, Adequate 0 person, Good 1 person, Excellent 47 person. In case of repeatly patient, we examinate abdomianl CT scan by using low kVp and body mass index less than 25. We can has good quality image and benefit of low radiation dose.