Browse > Article
http://dx.doi.org/10.5392/JKCA.2013.13.06.331

Evaluation of Image Quality and dose with the Change of kVp and BMI in the Liver CT  

Kim, Dong-Hyun (부산가톨릭대학교 보건과학대학 방사선학과)
Ko, Sung-Jin (부산가톨릭대학교 보건과학대학 방사선학과)
Kang, Se-Sik (부산가톨릭대학교 보건과학대학 방사선학과)
Kim, Jung-Hoon (부산가톨릭대학교 보건과학대학 방사선학과)
Choi, Seok-Yoon (부산가톨릭대학교 보건과학대학 방사선학과)
Kim, Changsoo (부산가톨릭대학교 보건과학대학 방사선학과)
Publication Information
Abstract
CT for follow-up visits because of liver disease, body mass index (BMI) and kVp according to the change of the image quality and radiation dose to evaluate for changes. March 2010 to June 2011 at Pusan P University Hospital, abdominal CT scans a patient BMI (Body Mass Index. Less BMI) index was less than 25 in the treatment of subjects had a 48-person Noise and SNR at 100kVp abdominal image is lager than the 120kVp image. CTDI volume value at by the analysis of the radiation dose is 4.47mGy(100kVp) and 9.01mGy(120kVp). So CTDIvol in 100kVp is smaller than CTDIvol in 120kVp(decrease by 44.1%). And, effective dose is 7.1mSv(100kVp) and 12.51mSv(120kVp). So effective dose in 100kVp is smaller than effective dose in 120kVp(decrease by 43%). Evaluation of image quality is that Unacceptable 0 person, Suboptimal 0 person, Adequate 0 person, Good 1 person, Excellent 47 person. In case of repeatly patient, we examinate abdomianl CT scan by using low kVp and body mass index less than 25. We can has good quality image and benefit of low radiation dose.
Keywords
kVp; BMI; CTDI; DLP;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 C. Suess and X. Chen, "Dose optimization in pediatric CT: current technology and future innovation," Pediatr Radiol, Vol.32, pp.729-734, 2002.   DOI   ScienceOn
2 B. Wintersperger, T. Jakobs, P. Herzog, S. Schaller, and K. Nikolaou, "Aorto-iliac multidetector-row CT angiograpy with low kV setting:improved vessel enhancement and simulataneous reduction of radiation dose," Eur Radiol, Vol.15, No.2, pp.334-341, 2005.   DOI   ScienceOn
3 D. J. Brenner, Radiaton risks potentially associated with low-dose CT screening of adult smokers for lung cancer, Radiology, Vol.231, pp.440-445, 2004.   DOI   ScienceOn
4 S. Yoshinaga, K. Mabuchi, A. J. Sigurdson, M. M. Doody, and E. Ron, Cancer risks among radiologists and radiologic technologists: review of epidermiologicstudies, Radiology, Vol.233, pp.313-321, 2004.   DOI   ScienceOn
5 고인호, 김경근, 김동윤, Textbook of Computed Tomography, p.62, 청구문화사, 2003.
6 S. Gryspeerdt, G. Hoe, L. V. Marchal, and A. L. Baert, "Evaluation of hepatic perfusion disorders with double-phase spiral CT," RadioGraphics, Vol.17, pp.337-348, 1997.   DOI   ScienceOn
7 J. P. Heiken, J. A. Brink, and M. W. Vannier, "Spiral(helical)CT," Radiology, Vol.189, pp.647-656, 1993.   DOI
8 R. K. Zeman and S. H. Fox, "Silverman PM,etal.Helical(spiral)CT of abdomen," AJR Vol.160, pp.719-725, 1993.   DOI   ScienceOn
9 M. A. Hoon, S. J. Lee, and S. A. Kim, "Usefulness of Follow-up Computed Tomography after Surgery for Early Gastric Cancer," J Korean Radioi Soc, Vol.47, pp.513-518, 2002.   과학기술학회마을   DOI
10 W. Huda, E. M. Scalzetti, and G. Levin, "Technique factors and image quality as functions of patient weight at abdominal CT," Radiology, Vol.217, pp.430-435, 2002.
11 A. B. Sigal-Cinqualbre, R. Hennequin, H. T. Abada, X. Chen, J. F. Paul, "Low-kilovoltage multi-detector row chest CT in adults:feasibility and effect on image quality and iodine dose," Radiology, Vol.231, pp.169-174, 2004.   DOI   ScienceOn
12 Y. Nakayama, K. Awai, Y. Funama, M. Hatemura, M. Imuta, and T. Nakaura, "Abdominal CT with low tube voltage: preliminary observation about radiation dose, contrast enhancement, image quality, and noise," Radiology, Vol.237, pp.945-951, 2005.   DOI   ScienceOn
13 Y. C. Nam, "복부 CT 검사시 SDCT와 MDCT의 선량비교 및 16채널 MDCT에서 scan parameter의 변화에 의한 선량비교", 대한전산화단층기술학회지, 제5권, 제1호, pp.55-63, 2006.
14 보건복지가족부, 식품의약품안전평가원, 대한영상의학회, 대한방사선협회, "CT 엑스선검사에서의 환자선량 권고량 가이드 라인", 방사선안전관리시리즈, No.19, 2009.
15 UNSCEAR 2000 Report Vol. I Sources and Effects of Ionization Radiation, Annex D Medical radiation exposure, UNSCEAR (2000)
16 B. Jung, A. H. Mahnken, A. Stargardt, J. Simon, T. G. Flohr, and S. Schaller, "Individual weigt-adepted examination protocol in retrospectively ECG-gated MSCT of the heart," Eur Radiol, Vol.13, pp.2560-2566, 2003.   DOI   ScienceOn
17 김문찬, "복부 CT검사시 technical factor 변화에 따른 환자피폭선량의 비교", 대한전산화단층기술학회지, 제4권, 제1호, p.91, 2003.
18 T. Irle and H. Inoue, "Individual modulation of the tube current-seconds to achieve similar levels of image noise in contrast-enhanced abdominal CT," AJR Am J Roentgenol, Vol.184, pp.1514-1518, 2005.   DOI   ScienceOn
19 K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, and M. Kanematsu, "Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity," AJR Am J Roentgenol, Vol.190, pp.777-784, 2008.   DOI   ScienceOn
20 김윤경, "체질량 지수 및 관전압 변화에 따른 CT 관상동맥 조영술에서 영상의 질 및 방사선 피폭량 비교," 대한 영상 의학회지, 제62권, pp.29-35, 2010.
21 D. Brenner, C. Elliston, and W. Berdon, "Estimated risks of radiation-induced fatal cancer from pediatric CT," AJR Am J Roentgenol, Vol.176, pp.289-296, 2001.   DOI   ScienceOn
22 D. J. Brenner and C. D. Elliston, Estimated radiaton risks potentially associated with full-body CT screening, Radiology, Vol.232, pp.735-738, 2004.   DOI   ScienceOn