• Title/Summary/Keyword: VP16

Search Result 145, Processing Time 0.022 seconds

Transcriptional Regulation of the VP16 Gene of Herpes Simplex Virus Type 1

  • Kwun, Hyun-Jin;Jun, Hong-Ki;Lee, Tae-Ho;Jang, Kyung-Lib
    • BMB Reports
    • /
    • v.32 no.5
    • /
    • pp.456-460
    • /
    • 1999
  • The promoter of the HSV-1 VP16 gene contains binding sites for the cellular transcription factors such as USF, CTF, and Sp1, each of which affects basal level expression of the VP16 gene. Transcription of the VP16 gene was induced by viral immediate-early proteins, ICP0 and ICP4, in a synergistic manner but repressed by ICP22. To gain further insight into the role of ICP0 in the expression of the VP16 gene during virus infection, several mutants with deletions in each of their transcriptional regulatory elements were generated. According to transient gene expression assays of these mutants using the CAT gene as a reporter, the USF and CTF binding sites were necessary for efficient induction of the promoter in the presence of transfected ICP0 or during virus infection, whereas the Sp1 binding site had little effect on ICP0-mediated VP16 expression. These results indicate that the immediate early proteins of HSV-1 regulate expression of the VP16 gene during virus infection by modulating the activities of cellular transcription factors such as USF and CTF.

  • PDF

Characterization of tTA and Its Functional Domain in Tetracycline Repressor-mediated Gene Repression System

  • Kim, Hong-Jin;Kim, Ki-Ho
    • Archives of Pharmacal Research
    • /
    • v.21 no.3
    • /
    • pp.320-325
    • /
    • 1998
  • To elucidate of role(s) of tTA as a repressor in the tTA-mediated gene repression system, we introduced mutations into the acidic domain of VP16 and examined the effects of such various mutations. In the transient repression experiment, a region containing 34 amino acids of the activation domain of VP16 (412-456) which interacts with TFIIB was found to be necessary and sufficient for the tTA-mediated repression of gene expression. However, in the experiment to investigate the fact that tTA-regulated repression is related to the activation function of VP16, we found that the repression abilities of tTA derivatives did not correlate exactly with their activation abilities. Therefore, we conclude that increased mass of VP16 in tTA might be also important for efficient repression in addition to functional domain of VP16.

  • PDF

Multiple hTAFII31-binding motifs in the intrinsically unfolded transcriptional activation domain of VP16

  • Kim, Do-Hyoung;Lee, Si-Hyung;Nam, Ki-Hoon;Chi, Seung-Wook;Chang, Ik-Soo;Han, Kyou-Hoon
    • BMB Reports
    • /
    • v.42 no.7
    • /
    • pp.411-417
    • /
    • 2009
  • Transcriptional activation domain (TAD) in virion protein 16 (VP16) of herpes simplex virus does not have any globular structure, yet exhibits a potent transcriptional activity. In order to probe the structural basis for the transcriptional activity of VP16 TAD, we have used NMR spectroscopy to investigate its detailed structural features. Results show that an unbound VP16 TAD is not merely "unstructured" but contains four short motifs (residues 424-433, 442-446, 465-467 and 472-479) with transient structural order. Pre-structured motifs in other intrinsically unfolded proteins (IUPs) were shown to be critically involved in target protein binding. The 472-479 motif was previously shown to bind to $hTAF_{II}31$, whereas the $hTAF_{II}31$-binding ability of other motifs found in this study has not been addressed. The VP16 TAD represents another IUP whose pre-structured motifs mediate promiscuous binding to various target proteins.

Expression of Gal4-VP16 and Gal4-DNA binding domain under the control of the T lymphocyte-specific lck proximal promoter in transgenic mice

  • Ryu, Chun-Jeih;Whitehurst, Charles E.;Chen, Jianzhu
    • BMB Reports
    • /
    • v.41 no.8
    • /
    • pp.575-580
    • /
    • 2008
  • Thymocyte-specific transcriptional regulatory systems can be used to better understand the relationship between transcription and V(D)J recombination during early T cell development. In this study, we generated transgenic mice expressing the transactivator Gal4-VP16 or the Gal4 DNA binding domain (Gal4-DBD) under the control of the lck proximal promoter, which is only active in immature thymocytes. From these studies Gal4-VP16 and Gal4-DBD expression was shown to significantly alter thymic cellularity and differentiation without significantly changing the $CD3^+$ thymocyte distribution. Furthermore, the presence of Gal4-VP16 or Gal4-DBD in the transgenic thymocytes retarded the mobility of the Gal4 DNA binding motif as determined by a gel mobility shift assay, suggesting that the developmental alteration did not affect the functional property of the transgenic proteins. These results indicated that lck promoter-driven Gal4-VP16 or Gal4-DBD expression did not affect $CD3^+$ mature thymocytes, thus this system can be applied to study transcriptional regulation of transresponder genes in bigenic mouse model thymocytes.

Design of Unified Inverse Transformer for HEVC and VP9 (HEVC 및 VP9 겸용 통합 역변환기의 설계)

  • Jung, Seulkee;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.596-602
    • /
    • 2015
  • In this paper, a unified inverse transformer is designed for HEVC and VP9. The proposed architecture performs all modes of HEVC and VP9 in the unified inverser transformer, such as $4{\times}4{\sim}32{\times}32$ HEVC IDCT, $4{\times}4$ HEVC IDST, $4{\times}4{\sim}32{\times}32$ VP9 IDCT, $4{\times}4{\sim}16{\times}16$ VP9 IADST and $4{\times}4$ IWHT. Same computations are used in HEVC IDCT and VP9 IDCT, except for the scales of the coefficients. Similarly, same computations are used in HEVC $4{\times}4$ IDST and VP9 $4{\times}4$ IADST, except for the scales of the coefficients. Furthermore, HEVC IDCT, VP9 IDCT, and VP9 IADST are the subsets of upper level IDCTs. The proposed architecture reuses multipliers when the computation is identical. Also it shares adders and butterfly structures even when the multiplier coefficients are different. So it reduces the hardware size significantly. Synthesized in 0.18 um technology, the gate count is 456,442 gates. which achieved 22.6% reduction compared to conventional architectures.

Effects of HIF-1α/VP16 Hybrid Transcription Factor on Estrogen Receptor in MCF-7 Human Breast Cancer Cells

  • Cho, Jung-Yoon;Park, Mi-Kyung;Lee, Young-Joo
    • Biomolecules & Therapeutics
    • /
    • v.13 no.4
    • /
    • pp.227-231
    • /
    • 2005
  • The estrogen receptor (ER) is activated and degraded by estrogen. We have examined ER downregulation and activation under hypoxia mimetic conditions. Cobalt chloride induced ER downregulation at 24 h of treatment. This degradation involved hypoxia-inducible factor-1$\alpha$ (HIF-1$\alpha$) as examined by using a constitutively active form of HIF-1$\alpha$, HIF-1$\alpha$/VP16, constructed by replacing the transactivation domain of HIF-1$\alpha$ with that of VP16. Western blot analysis revealed that E2-induced ER downregulation was observed within ${\~}6h$, whereas HIF-1$\alpha$/VP16-induced ER degradation was observed within 12${\~}$20h. HIF-1$\alpha$/VP16 activated the transcription of estrogen-responsive reporter gene in the absence of estrogen. These results suggest that ER downregulation and activation under hypoxia maybe mediated in part by a HIP-1$\alpha$ expression.

Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography (저 선량 전산화단층촬영의 관전압과 적응식 통계적 반복 재구성법 적용에 따른 영상평가 및 피폭선량)

  • Moon, Tae-Joon;Kim, Ki-Jeong;Lee, Hye-Nam
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.261-267
    • /
    • 2017
  • The study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying filter back projection (FBP), the existing test method, and adaptive statistical iterative reconstruction (ASIR) with different values of tube voltage during the low dose computed tomography (LDCT). With the image reconstruction method as basis, chest phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of tube voltage (100 kVp, 120 kVp). For image evaluation, back ground noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were measured, and, for dose assessment, CTDIvol and DLP were measured respectively. In terms of image evaluation, there was significant difference in ascending aorta (AA) SNR and inpraspinatus muscle (IM) SNR with the different amount of tube voltage (p < 0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120 kVp were 2.6 mGy with no-ASIR and 2.17 mGy with 20%-ASIR respectively, decreased by 0.43 mGy, and the values with 100 kVp were 1.61 mGy with no-ASIR and 1.34 mGy with 20%-ASIR, decreased by 0.27 mGy. In terms of DLP, the measured values with 120 kVp were $103.21mGy{\cdot}cm$ with no-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$ (about 16.7%), and the values with 100 kVp were $63.84mGy{\cdot}cm$ with no-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$ (about 16.7%). At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise.

The Study of Energy Compensation Filter Thickness for Each Energy Area of Low Energy X-ray Beam Optimization on Active Electronic Personal Dosimeter (능동형 전자식 개인피폭선량계의 저에너지 X선 영역별 최적화를 위한 에너지보상 필터 두께에 대한 연구)

  • Kim, Jung-Su;Park, Youn-Hyun;Chae, Hyun-Sic
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.519-526
    • /
    • 2022
  • Electronic personal dosimeter (EPD) provide real time monitoring and a direct indication of the accumulated dose or dose rate in terms of personal dose. Most EPD do not perform well in low energy photon radiation fields present in medical radiation environments. It has poor responsibility and large error rate for low energy photon radiation of medical radiation environments. This study evaluated to optimal additional filtration for EPD using silicon PIN photodiode detector form 40 to 120 kVp range in medical radiation environments. From 40 to 80 kVp energy range, Al 0.2 mm and Sn 1.0 mm overlapped filtration showed good responsibility to dose rate and from 80 kVp to 120 kVp energy range, Al 0.2 mm and Sn 1.6 mm overlapped filtration showed good responsibility to dose rate.

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.