• Title/Summary/Keyword: VCM

Search Result 204, Processing Time 0.029 seconds

A Dual-Servo Type VCM for a Nano-Level Measurement System

  • Yoo, Yong-Min;Kwon, Byung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.50-54
    • /
    • 2007
  • In this paper, a dual-servo type VCM (Voice Coil Motor) for the measuring of nano-level displacement and small thrust is proposed and developed. The shape of VCM for improving the resolution of displacement and ensuring a large displacement are presented. The FEM (finite element method) is utilized to analyze the characteristics of VCM that produces linear driving thrust and satisfies the thrust that the measurement system requires. The Prototype is fabricated and an experiment is performed in order to measure displacement. As a result of simulation and testing, the proposed VCM shows the applicable possibility for a nano-level measurement system.

A Method of Multi-Scale Feature Compression for Object Tracking in VCM (VCM 의 객체추적을 위한 다중스케일 특징 압축 기법)

  • Yong-Uk Yoon;Gyu-Woong Han;Dong-Ha Kim;Jae-Gon Kim
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.11a
    • /
    • pp.10-13
    • /
    • 2022
  • 최근 인공지능 기술을 바탕으로 지능형 분석을 수행하는 기계를 위한 비디오 부호화 기술의 필요성이 요구되면서, MPEG 에서는 VCM(Video Coding for Machines) 표준화를 시작하였다. VCM 에서는 기계를 위한 비디오/이미지 압축 또는 비디오/이미지 특징 압축을 위한 다양한 방법이 제시되고 있다. 본 논문에서는 객체추적(object tracking)을 위한 머신비전(machine vision) 네트워크에서 추출되는 다중스케일(multi-scale) 특징의 효율적인 압축 기법을 제시한다. 제안기법은 다중스케일 특징을 단일스케일(single-scale) 특징으로 차원을 축소하여 형성된 특징 시퀀스를 최신 비디오 코덱 표준인 VVC(Versatile Video Coding)를 사용하여 압축한다. 제안기법은 VCM 에서 제시하는 기준(anchor) 대비 89.65%의 BD-rate 부호화 성능향상을 보인다.

  • PDF

SAD-Based Reordering of Feature Map Sequence for VCM (VCM 을 위한 SAD 기반 특징맵 시퀀스 재배열)

  • Kim, Dong-Ha;Yoon, Yong-Uk;Kim, Jae-Gon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • fall
    • /
    • pp.30-32
    • /
    • 2021
  • 최근 머신비전 임무(machine vision task)를 위해 기계에 소비되는 비디오가 증가하면서 MPEG 은 기계를 위한 비디오 부호화 표준으로 VCM(Video Coding for Machine) 표준화 진행하고 있다. VCM 은 기계분석 네트워크에 입력되는 비디오 또는 특징(feature)을 부/복호화하여 압축 대비 임무 수행 정확도를 평가한다. 본 논문은 기계분석 네트워크에서 추출한 특징 데이터를 기존의 비디오 코덱을 사용하여 부/복호화를 진행할 때, 각 채널의 특징맵을 SAD(Sum of Absolute Difference) 기반으로 재배열하는 방법을 제안한다. 제안기법은 VCM 의 기준성능(anchor)에는 미치지 못하지만, 채널 재배열하지 않은 특징을 비디오 코덱으로 부호화 할 때 보다 개선된 성능을 보인다.

  • PDF

Compression of Multiscale Features of FPN for VCM (VCM 을 위한 FPN 다중 스케일 특징 압축)

  • Kim, Dong-Ha;Yoon, Yong-Uk;Lee, Jooyoung;Jeong, Se-Yoon;Kim, Jae-Gon;Jeong, Dae-Gwon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2022.06a
    • /
    • pp.143-145
    • /
    • 2022
  • MPEG-VCM(Video Coding for Machine)은 입력된 비디오 특징(feature)를 압축하는 Track1 과 입력 영상을 직접 압축하는 Track2 로 나뉘어 표준화가 진행중이다. 본 논문은 VCM Track 1 에 해당하는 Detectron2 FPN(Feature Pyramid Network)에서 추출한 다중 스케일 특징맵을 VVC 로 압축하는 MSFC(Multi-Scale Feature Compression)을 구조를 제안한다. 본 논문의 MSFC 에서는 다중 스케일 특징을 결합하여 부호화/복호화하는 기존의 구조에서 특징맵의 해상도를 줄여 압축하는 개선된 MSFC 를 제시한다. 제안 방법은 VCM 의 Track2 의 영상 앵커(image anchor) 보다 우수한 BPP-mAP 성능을 보이고 최대 -84.98%의 BD-rate 성능향상을 보인다.

  • PDF

Development of Rotary VCM type Actuator for Small Form Factor ODD (초소형 ODD 용 로터리 VCM 타입 엑추에이터 개발)

  • Kim, Yoon-Ki;Kim, Sa-Ung;Lee, Dong-Joo;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.672-675
    • /
    • 2006
  • It is becoming more significant to develop a rotary VCM type actuator for small form factor ODD, as portables are getting more and more popularized nowadays. In this paper, the procedure of development of the actuator which is applicable to compact flash II card and is fit in the specification of BD 1X is explained. This is based on the rotary VCM type actuator, which is good for reducing thickness. Air core solenoid coil is used in order to do focusing mechanism. And the total weight is reduced by using the structure of steel-aluminium-steel triple layer, so, the stiffness is still adequate. Additionally, the tracking coil is moved next to the actuator, so the total length was reduced, then the actuator become applicable to compact flash II card. The force of Magnetic Circuit is improved by using Magnetic Circuit DOE. And flexible mode frequency improved through the DOE of structure part. Modeling was exactly done in consideration of air core solenoid coil and pivot bearing. It is confirmed that the designed model is satisfied with the specification of BD 1X and is applicable to Compact Flash II card.

  • PDF

Development of Music Classification of Light and Shade using VCM and Beat Tracking (VCM과 Beat Tracking을 이용한 음악의 명암 분류 기법 개발)

  • Park, Seung-Min;Park, Jun-Heong;Lee, Young-Hwan;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.6
    • /
    • pp.884-889
    • /
    • 2010
  • Recently, a music genre classification has been studied. However, experts use different criteria to classify each of these classifications is difficult to derive accurate results. In addition, when the emergence of a new genre of music genre is a newly re-defined. Music as a genre rather than to separate search should be classified as emotional words. In this paper, the feelings of people on the basis of brightness and darkness tries to categorize music. The proposed classification system by applying VCM(Variance Considered Machines) is the contrast of the music. In this paper, we are using three kinds of musical characteristics. Based on surveys made throughout the learning, based on musical attributes(beat, timbre, note) was used to study in the VCM. VCM is classified by the trained compared with the results of the survey were analyzed. Note extraction using the MATLAB, sampled at regular intervals to share music via the FFT frequency analysis by the sector average is defined as representing the element extracted note by quantifying the height of the entire distribution was identified. Cumulative frequency distribution in the entire frequency rage, using the difference in Timbre and were quantified. VCM applied to these three characteristics with the experimental results by comparing the survey results to see the contrast of the music with a probability of 95.4% confirmed that the two separate.

Study on the control of VCM and its application to the vibration isolator (VCM의 제어 및 제진 장치 응용에 관한 연구)

  • Kim, Jin-Man;Nam, Taek-Kun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • The degradation of durability and increase of fatigue on the ship are mainly caused by vibration of the engine and rotating machineries. The damper to minimize the influence from vibration is usually attached between the machineries and its base. General damper applied on the vessel is passive damper which is designed to attenuate specified frequency signals, i.e, high frequency vibration signals. But it is hard to anticipate its performance for low frequency signals. In this research, active vibration isolator using VCM is developed to suppress wide band vibration signals. Routh-Huritz's stable condition, ultimate sensitivity method and parameter tuning are applied to derive PID parameters and 2 and 4 phase choppers are also adapted to drive VCM. Simulation and experiments are executed to confirm the effectiveness of the proposed control schemes.

The level of urinary malondialdehyde concentrations in vinyl chloride monomer exposure workers (염화비닐 노출 근로자의 요중 Malondialdehyde 농도 수준)

  • Kim, Hyun Soo;Kim, Chi-Nyon;Won, Jong Uk;Park, Jun Ho;Kim, Gwang Suk;Ahn, Mi Hyun;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.81-88
    • /
    • 2007
  • The aim of this study was to investigate whether the exposure to vinyl chloride monomer(VCM) induces lipid peroxidation in workers by evaluating the concentration of malondialdehyde(MDA) in the urine in order to assess worker's oxidative stress due to exposure of vinyl chloride monomer. The subjects investigated in the study were divided into the experimental group; 18 workers exposed to VCM, and the control group; 19 workers unexposed to VCM. A gas chromatography/pulsed flame photometric detector(GC/PFPD) was utilized to analyze thiodiglycolic acid(TDGA), which was methylated with trimethylsilyldiazomethane (2.0M in diethyl ether) in urine and the urinary MDA, the product of lipid peroxidation, was determined by high-performance liquid chromatography/ultraviolet-visible detector after derivatized with 2,4-dinitrophenylhydrazine(DNPH). The concentrations of urinary TDGA in controls and VCM exposure workers were 0.13(2.01)mg/g Cr. GM(GSD) and 0.35(1.96)mg/gCr. GM(GSD), respectively. The concentrations of urinary MDA were $0.12(2.21){\mu}mol/gCr$. GM(GSD) in controls and $1.35(1.79){\mu}mol/gCr$. GM(GSD) in VCM exposure workers. As a result of simple regressions analysis between urinary concentration of TDGA and MDA in VCM exposure workers, it was found that the $R^2$ value was 0.261 (p=0.03) and the drinking and smoking did not affect their level. In conclusion, the workers exposed to VCM have a potentially to suffered by oxidative stress due to VCM exposure and the urinary MDA can be applicable to the marker of effect to assess the level of worker's VCM exposure.

Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling (공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향)

  • Yoon, Jon Jung;Lim, Nam Gu;Kim, Chi Nyun;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF

Development of Rotary VCM type Actuator for Small Form Factor Optical Disk Drive (초소형 광디스크 드라이브용 VCM타입 엑추에이터 개선)

  • Woo, Jung-Hyun;Kim, Sa-Ung;Song, Myong-Gyu;Lee, Dong-Joo;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.474-478
    • /
    • 2006
  • It is becoming more significant to develop a rotary voice coil motor(VCM) type's actuator for small form factor (SFF) optical disk drive(ODD), as portables are getting more and more popularized nowadays. The actuator which is applicable to small-sized ODD with a compact flash(CF) II card size was developed and fabricated. The experimental results showed that the finite element(FE) model is different from the fabricated model. And so flexible mode frequencies did not satisfy specifications of small-sized ODD, and tuning. Tuning procedures were required to improve dynamic characteristics of the fabricated actuator through finite difference method(FDM). At first, design variables were extracted through parameter study and the tuned FE model was improved by design of experiment(DOE). Consequently, It was confirmed that the improved model was applicable to SFF ODD.

  • PDF