• 제목/요약/키워드: V.A.K.

검색결과 24,917건 처리시간 0.054초

한전 765kV 변전소의 기본설계 개요 (A summary of KEPCO's 765kV substation design)

  • 김문덕;정시환;김종화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2139-2142
    • /
    • 1999
  • 765kV substations which will be the core installation of the bulk power transmission system in Korea for the upcoming $21^{st}$ century, were designed of outdoor full GIS type to minimize required area. As principal equipment, main transformers of 2,000 MVA per bank and 50kA 8,000A gas insulated switchgears of up-to-date technology were adopted in designing substations to transmit bulk power of 10GW. Dual digital protective relay systems and distributed indication and control systems with fiber optic LAN were used.

  • PDF

국내 345kV 변전소 하위 154kV 계통 연계지점 SFCL 적용방안에 관한 연구 (A study on SFCL application for 154kV power system interconnection of 345kV S/S in Korean power system)

  • 이승렬;김종율;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.340-343
    • /
    • 2005
  • This paper is for studying the feasibility of SFCL application for the interconnection operation of 154kV power systems under 345kV S/S in Korean power system. All Korean 154kV power systems are constructed as loop systems in downtown. However, the present 154kV systems are operated with separated systems around 345kV S/S because of fault current and overload problems. In this study, we investigate the structure and operation of 154kV power system in Seoul and study the feasibility of interconnection operation of 154kV systems under 345kV systmes by applying SFCLs to 154kV bus-tie.

  • PDF

A NOTE ON CONNECTEDNESS IM KLEINEN IN C(X)

  • BAIK, BONG SHIN;RHEE, CHOON JAI
    • 한국수학교육학회지시리즈B:순수및응용수학
    • /
    • 제22권2호
    • /
    • pp.139-144
    • /
    • 2015
  • Abstract. In this paper, we investigate the relationships between the space X and the hyperspace C(X) concerning admissibility and connectedness im kleinen. The following results are obtained: Let X be a Hausdorff continuum, and let A ∈ C(X). (1) If for each open set U containing A there is a continuum K and a neighborhood V of a point of A such that V ⊂ IntK ⊂ K ⊂ U, then C(X) is connected im kleinen. at A. (2) If IntA ≠ ø, then for each open set U containing A there is a continuum K and a neighborhood V of a point of A such that V ⊂ IntK ⊂ K ⊂ U. (3) If X is connected im kleinen. at A, then A is admissible. (4) If A is admissible, then for any open subset U of C(X) containing A, there is an open subset V of X such that A ⊂ V ⊂ ∪U. (5) If for any open subset U of C(X) containing A, there is a subcontinuum K of X such that A ∈ IntK ⊂ K ⊂ U and there is an open subset V of X such that A ⊂ V ⊂ ∪ IntK, then A is admissible.

0.35 ㎛ BCD 공정을 이용한 보호회로 기능이 추가된 모바일용 LDO 레귤레이터 (Design of a LDO regulator with a protection Function using a 0.35 µ BCD process)

  • 이민지;손현식;박용수;송한정
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.627-633
    • /
    • 2015
  • 본 논문에서는 고속 PMIC(Power Management Integrated Circuit) 회로를 위한 저전압 입력 보호기능을 가지는 모바일용 LDO(Low Drop-Out) 레귤레이터를 설계하였다. 설계된 LDO 레귤레이터는 밴드갭 기준전압회로, 오차 증폭회로, 파워 트랜지스터 등으로 이루어진다. LDO 레귤레이터는 3.3 V 전원전압으로부터 2.5 V 출력을 갖도록 설계되었으며, 저전압 입력보호 기능을 하는 UVLO 회로는 전원부와 파워 트랜지스터 사이에 삽입된다. 또한 UVLO는 3.3 V 구동전압에서, 하강시 1.2 V 에서 LDO 레귤레이터 동작을 멈추게 하고, 구동전압 상승 시 2.5 V 에서 LDO 레귤레이터가 정상 동작한다. $0.35{\mu}m$ 5 V 저전압 CMOS 공정을 사용하여 모의실험 한 결과, 설계한 LDO 레귤레이터는 0.713 mV/V의 라인레귤레이션을 가지고, 부하전류가 0 mA에서 40 mA로 변할 때 $8.35{\mu}V/mA$의 로드레귤레이션을 보였다.

UVLO 보호기능이 추가된 LDO 레귤레이터 설계 (Design of a Low Drop-out Regulator with a UVLO Protection Function)

  • 박원경;이수진;박용수;송한정
    • 전자공학회논문지
    • /
    • 제50권10호
    • /
    • pp.239-244
    • /
    • 2013
  • 본 논문에서는 고속 PMIC(Power Management Integrated Circuit) 회로를 위한 저전압 입력 보호기능을 가지는 UVLO(Under Voltage Lock Out) 기능이 탑재된 LDO(Low Drop-Out) 레귤레이터를 설계하였다. 설계된 LDO 레귤레이터는 밴드갭 기준전압 회로, 오차 증폭회로, 파워 트랜지스터 등으로 이루어지진다. LDO 레귤레이터는 5 V 전원전압으로부터 3.3 V 출력을 갖도록 설계되었으며, 저전압 입력보호 기능을 하는 UVLO 회로는 전원부와 파워 트랜지스터 사이에 삽입된다. 또한 UVLO는 5 V 구동전압에서, 하강 시 2.7 V 에서 LDO 레귤레이터 동작을 멈추게 하고, 구동전압 상승 시 4.0 V 에서 LDO 레귤레이터가 정상 동작한다. $1{\mu}m$ 20 V 고전압 CMOS 공정을 사용하여 모의실험 한 결과, 설계한 LDO 레귤레이터는 5.88 mV/V의 라인레귤레이션을 가지고, 부하전류가 0 mA에서 200 mA로 변할 때 27.5 uV/mA의 로드레귤레이션을 보였다.

A MASCHKE-TYPE THEOREM FOR THE GRADED SMASH COPRODUCT C⋊kG

  • Kim, Eun-Sup;Park, Young-Soo;Yoon, Suk-Bong
    • 대한수학회보
    • /
    • 제36권2호
    • /
    • pp.337-342
    • /
    • 1999
  • M. Cohen and S. Montgomery showed that a Maschke-type theorem for the smash product, which unlike the corresponding result for group actions, does not require any assumptions about the characterstic of the algebra. Our purpose in this paper is a Maschke-type theorem for the graded smash coproduct C⋊kG: let V be a right C⋊kG-comodule and W a C⋊kG-subcomoduleof V which is a C-direct summand of V. Then W is a C⋊kG-direct summand of V. Also this result is equivalent to the following : let V be a graded right C-comodule and W a graded subcomodule of V which has a complement as a C-subcomodule of V. Then W has a graded complement.

  • PDF

수요분석을 통한 154kV 계통전압 유지기준 설정 (An examination on proper voltage operation standard for 154kV power system through demand analysis)

  • 이익종;이상중
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.428-431
    • /
    • 2009
  • 안정적인 전력계통 운영을 위한 공급전압별 유지기준의 설정은 대단히 중요하다. 유지기준은 현재 정부고시로 제정 운영되고 있다. 우리나라의 공급전압은 345kV-154kV-22.9kV 및 380V-220V-110V로 구성되어 있다. 본 논문에서는 전기품질 유지관리에 영향을 주는 계통전압 중, 154kV를 중심으로 수요분석을 통해 유지기준이 적정한지를 살펴보고 이를 토대로 현재의 전력계통 수요에 적합한 유지기준을 고찰해 보고자 한다.

  • PDF

Comparison of Insulation Coordination Between ±800kV and ±1100kV UHVDC Systems

  • Wang, Dong-ju;Zhou, Hao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1773-1779
    • /
    • 2015
  • Insulation coordination is a key problem in UHVDC systems in terms of safety and cost. Although high-voltage ±1100kV UHVDC projects are being planned in China, the characteristics and key points of high-voltage systems have not yet been analyzed. This study aims to improve the safe, effective operation of these high-voltage power transmission systems. First, we analyzed two typical insulation coordination schemes used in ±800kV UHVDC systems in China. Next, we used the two typical ±800kV insulation coordination schemes as a reference to analyze the ±1100kV UHVDC system. Finally, we compared these schemes and proposed an effective insulation coordination solution, as well as developing principles for ±1100kV UHVDC systems. Our findings indicate that the points enduring the highest voltage in the system should be protected separately by special arresters. Our analysis of the insulation coordination of ±800kV and ±1100kV UHVDC systems concluded that, in ±1100kV UHVDC systems, the main goal of insulation coordination is to lower the insulation level of points enduring the highest voltage. However, in a ±800kV UHVDC system, the main goal is to reduce the cost of manufacture for arresters, as well as the space occupation in the valve hall, with an acceptable insulation level.

Characterization of the v-cath Gene of Bombyx mori Nuclear Polyhedrosis Virus K1

  • Lee, Kwang Sik;Li, Jianhong;Je, Yeon Ho;Woo, Soo Dong;Sohn, Hung Dae;Jin, Byung Rae
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제9권2호
    • /
    • pp.217-223
    • /
    • 2004
  • A cathepsin L-like cysteine protease, v-cath, encoded by the baculovirus has been shown to playa role in host liquefaction. We have identified a v-cath gene in the silkworm virus, Bombyx mori nuclear polyhedrosis virus (BmNPV) K1 strain. The 969 bp v-cath has an open reading frame of 323 amino acids. A putative cleavage site and catalytic sites were conserved in BmNPV-K1 v-cath. The predicted three-dimensional structure of BmNPV-K1 v-cath revealed that the overall fold of BmNPV-K1 v-cath is similar to that of other proteases of the papain family. The deduced amino acid sequence of BmNPV-K1 v-cath showed 98% and 97% protein sequence identity to BmNPV T3 strain and to Autographa californica nuclear polyhedrosis virus, respectively. The BmNPV-K1 v-cath differed at 4 amino acid positions from BmNPV T3. The v-cath gene in BmNPV-K1 genome is located on the EcoRV 6 kb and XhoI 9 kb fragments. Northern hybridization analysis of BmNPV K1 v-cath gene revealed that it is expressed late in infection.

345kV-154kV 탭 감도를 활용한 한전 계통 수도권 345kV 과전압 해소 방안 (A Solution for 345kV Overvoltage in KEPCO System using 345kV-154kV Tap Sensitivity)

  • 배문성;조환희;이병준;최장흠;차승태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.278-279
    • /
    • 2015
  • 한전 계통의 수도권 부하 밀집과 지중화 선로 증가로 인해 수도권 345kV 계통 과전압이 큰 문제가 되고 있다. 조상설비 투입 후에도 과전압이 문제가 되는 경우, 과전압 해소를 위한 다른 방안이 필요하다. 본 논문에서는 345kV 과전압 해소를 위한 345kV-154kV 변압기 탭조절 방안을 검토하였다. 효율적인 과전압 해소를 위해 탭 감도를 이용하여 탭 조절을 수행하였다. 또한 일반적인 경우 345kV-154kV 변압기의 2차측 전압을 올리면 1차측 전압이 떨어지지만 본 논문에서는 그렇지 않은 경우를 찾아내고 해당 원인을 분석하였다. 모의를 위한 데이터는 2014년 한전 과전압 모의 데이터를 사용하였다.

  • PDF